Desa LAME-MAX Golden Oak, FLAME-MAX VintageOak installation manual Parts Available not Shown QTY

Page 35

PARTS LIST

Variable Manually-Controlled Flame-Max®Golden Oak Log Models VYD18PA, VYD24PA, VYD30PA and VYD36PA

35

PARTS LIST

VARIABLE MANUALLY-CONTROLLED

FLAME-MAX®GOLDEN OAK LOG MODELS

This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 29 of this manual.

KEY

PART NUMBER FOR

 

 

 

NO.

VYD18PA

VYD24PA

VYD30PA

VYD36PA

DESCRIPTION

1

110397-03

110397-04

110397-05

Five-Piece Golden Oak Log Set

1-1

110315-01

110313-01

110320-01

Front Log

1-2

110315-02

110313-02

110320-02

Rear Log

1-3

110315-03

110313-03

110320-03

Center Log

1-4

110315-04

110313-04

110320-04

Top Right Log

1-5

110315-05

110313-05

110320-05

Top Left Log

2

105268-01

105268-02

105268-03

107027-01

One-Piece Golden Oak Log Set

3

098276-01

098276-01

098276-01

098276-01

Hex Head Plug 1/8" NPT

4

098249-01

098249-01

098249-01

098249-01

Nut, M5

5

102775-04CK

102775-01CK

102775-03CK

102775-03CK

Painted Base Assembly

6

102844-02

102844-01

102844-01

102844-01

Lower Bracket

7

102966-02

102966-01

102966-01

102966-01

Upper Bracket

8

098867-10

098867-10

098867-10

098867-10

Gas Regulator

9

102798-01

102798-01

102798-01

102798-01

Inlet Tube

10

102779-04

102779-02

102779-02

102779-02

Outlet Burner Tube

11

099056-19

099056-17

099056-17

099056-17

Burner Orifice Injector

12

102843-01

102843-01

102843-01

102843-01

Burner Clip

13

102980-01

102772-01

102772-01

102772-01

Burner

14

102568-08

102568-06

102568-06

102568-06

Control Valve

15

098508-01

098508-01

098508-01

098508-01

Valve Retainer Nut

16

098354-01

098354-01

098354-01

098354-01

Control Knob

17

102445-01

102445-01

102445-01

102445-01

Piezo Ignitor (14261)

18

099387-08

099387-08

099387-08

099387-08

Pilot Tube

19

098271-10

098271-10

098271-10

098271-10

Ignitor Cable

20

104286-01

104286-01

104286-01

104286-01

ODS Pilot

21

M11084-38

M11084-38

M11084-38

M11084-38

Screw, Hex Head (#8-18 x .38)

 

 

 

 

 

 

PARTS AVAILABLE — NOT SHOWN

QTY.

1

1

1

1

1

1

1

2

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

11

100563-01

101055-02

100565-01

100639-01

101449-04

101137-02 GA6060

100563-01

101055-02

100565-01

100639-01

101449-04

101137-02 GA6060

100563-01

101055-02

100565-01

100639-01

101449-04

101137-02 GA6060

100563-01

101055-02

100565-01

100639-01

101449-04

101137-02 GA6060

Warning Plate

Lighting Instructions Plate

Warning Plate Fastener

Caution Decal

Control Position Decal

Hardware Kit

Lava Rock

1

1

1

1

1

1

1

For morevisit www..com

110399-01B

Image 35
Contents What to do if YOU Smell GAS Unvented VENT-FREE GAS LOG HeaterSafety Information Table of ContentsSafety Information Unpacking Optional Remote Control AccessoriesProduct Identification Local CodesAIR for Combustion and Ventilation Product FeaturesDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationSee options 1 and 2, . You can also remove door into Ventilation AIRVentilation Air From Inside Building Ventilation Air From OutdoorsMeasured at 14 depth InstallationCheck GAS Type LOG Sizing RequirementsMinimum Noncombustible Material Clearances If Not Using MantelDetermining Minimum Mantel Clearance Mantel ClearancesFloor Clearances Area of Various Standard Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Installation Items NeededAttach base assembly to fireplace floor using two masonry Trol accessories, do so at this time Remote-Ready ModelsOnly. Follow all directions provided with accessory Drill holes at marked locations using 3/16 drill bitExternal Regulator With Vent Pointing Down Connecting to GAS SupplyClose equipment shutoff valve see , Pressure Testing gas Supply Piping systemChecking GAS Connections Vintage Oak Two-Piece Log Set Installing LogsPressure Testing Heater Gas Connections Golden Oak One-Piece Log Set Installing Vintage Oak Two-Piece Log SetGolden Oak Five-Piece Log Set Installing Golden Oak 5-Piece Log Set LogLighting Instructions Operating HeaterShutting Off Heater Manual Lighting ProcedureTo Turn OFF GAS to Appliance Thermostat Control OperationVariable Control Operation REMOTE-READY Models For Your Safety Read Before LightingFlame Adjustment Knob Ghrcta Series Operation Optional Remote OperationThermostat Control Operation Ghrc Series OperationMain Burner Inspecting BurnersPilot Flame Pattern Burner Primary AIR HolesWe also recommend that you keep the burner tube and pilot Cleaning and MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole LogsTroubleshooting Clean burner see Cleaning and Mainte Company ODS/pilot is partially clogged Clean ODS/pilot see CleaningGas odor even when control knob is in OFF Low line pressureThermostat-Controlled Models Only Optional Positioning of Thermostat Sensing BulbFor Masonry and FACTORY-BUILT Metal Fireplace Golden Oak Golden Oak 24 Remote-Ready 36 Remote-Ready SpecificationsReplacement Parts Wiring DiagramService Hints Technical ServiceAccessories ODS Pilot Natural Gas ODS Pilot Propane/LP Illustrated Parts BreakdownVariable MANUALLY-CONTROLLED FLAME-MAXVINTAGE OAK LOG Models Parts ListVariable MANUALLY-CONTROLLED FLAME-MAXGOLDEN OAK LOG Models Parts Available not Shown QTY From drawing.4 Natural GasParts Available not Shown THERMOSTAT-CONTROLLED FLAME-MAXGOLDEN OAK LOG Models Auxiliary Thermostat Mounting Clip REMOTE-READY FLAME-MAXGOLDEN OAK LOG Models Parts List VYD36PNA and HD36NR Parts List For . .com Owners Registration Form Postage Required 110399-01B Warranty Information