Desa CGP11A installation manual Checking, Pressure Testing Heater GAS Connections

Page 15

CHECKING

3.

Pressurize supply piping system by either using compressed air or

 

opening propane supply tank valve.

GAS

 

4. Check all joints of gas supply piping system. Apply mixture of liquid soap and

CONNECTIONS

 

water to gas joints. Bubbles forming show a leak.

5.

Correct all leaks at once.

Continued

Test Pressures Equal To or Less Than 1/2 PSIG

 

 

1.

Close manual shutoff valve (see Figure 14).

 

2.

Pressurize supply piping system by either using compressed air or opening

 

 

propane supply tank valve.

 

3.

Check all joints from propane supply tank to manual shutoff valve (see Figure

 

 

15). Apply mixture of liquid soap and water to gas joints. Bubbles forming

 

 

show a leak.

 

4.

Correct all leaks at once.

 

PRESSURE TESTING HEATER GAS CONNECTIONS

 

1.

Open manual shutoff valve (see Figure 14).

 

2.

Open propane supply tank valve.

 

3.

Make sure control knob of heater is in the OFF position.

 

4.

Check all joints from manual shutoff valve to control valve (see Figure 15).

 

 

Apply mixture of liquid soap and water to gas joints. Bubbles forming show a

 

 

leak.

 

5.

Correct all leaks at once.

 

6.

Light heater (see Operating Heater, pages 16 through 19). Check all other

 

 

internal joints for leaks.

 

7.

Turn off heater (see To Turn Off Gas To Appliance, page 19).

 

8.

Replace front panel.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Open

 

 

 

 

 

 

 

 

Manual

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Shutoff

 

 

Valve

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Closed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 14 - Manual Shutoff Valve

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Valve Location

 

 

Propane

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Supply Tank

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Manual

Shutoff

Valve

Figure 15 - Checking Gas Joints

15

100846

Image 15
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualContents Safety Information Unpacking Safety DeviceProduct Local CodesProducing Adequate Ventilation Fresh AIR ForCombustion VentilationFresh AIR Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Fresh AIR for Combustion and Ventilation Ventilation AIRVentilation Air From Inside Building Ventilation Air From Outdoors Ventilation AIRLocating Heater Installing To WallInstallation Items Check GAS TypeMarking Screw Locations Installing Heater to WallFolding Anchor Installing Two Mounting ScrewsPlacing Heater On Mounting Screws Follow all local codes Connecting To GASQualified service person must connect heater to gas supply SupplyServicing. Correct all leaks at once Pressure Testing GAS Supply Piping SystemChecking GAS ConnectionsChecking Pressure Testing Heater GAS ConnectionsOperating Heater For Your Safety Read Before LightingPilot To Select Heating Level Pilot Flame Pattern HeaterInspecting BurnerBurner Flame Pattern Inspecting BurnerTrouble Shooting ODS/PILOT and Burner OrificeCabinet TROUBLE- Shooting See CleaningMaintenance, Technical Service Ing statement atTop Parts Not Under Warranty ServiceReplacement Parts Parts Under WarrantyService Publications Accessory Parts CentralsValve GA5010 Illustrated Parts Breakdown Parts ListKeep this Warranty Warranty Information