OPERATING HEATER

Continued

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you then smell gas, STOP! Follow “B” in the safety infor- mation at the top of page 16. If you don’t smell gas, go to the next step.

5. Press in control knob, and turn counterclockwise C-clockwiseto pilot position.

Keep control knob pressed for five seconds.

Note: You may be running this heater for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds. This will allow air to bleed from the gas system.

If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.

6.With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is attached to the front of burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not light, refer to Troubleshooting, pages 21 through 24. Also contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 19.

Thermocouple

Ignitor Electrode

Pilot Burner

 

Figure 17 - Pilot

7.Keep control knob pressed in for 10 seconds after lighting pilot. After 10 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7.

Continued

100846

17

Image 17
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualContents Safety Information Product Safety DeviceLocal Codes UnpackingCombustion Fresh AIR ForVentilation Producing Adequate VentilationDetermining if You Have a Confined or Unconfined Space Fresh AIRDetermining FRESH-AIR Flow for Heater Location Ventilation Air From Inside Building Fresh AIR for Combustion and VentilationVentilation AIR Ventilation Air From Outdoors Ventilation AIRInstallation Items Installing To WallCheck GAS Type Locating HeaterMarking Screw Locations Installing Heater to WallFolding Anchor Installing Two Mounting ScrewsPlacing Heater On Mounting Screws Qualified service person must connect heater to gas supply Connecting To GASSupply Follow all local codesChecking GAS Pressure Testing GAS Supply Piping SystemConnections Servicing. Correct all leaks at onceChecking Pressure Testing Heater GAS ConnectionsOperating Heater For Your Safety Read Before LightingPilot To Select Heating Level Inspecting HeaterBurner Pilot Flame PatternBurner Flame Pattern Inspecting BurnerCabinet Trouble ShootingODS/PILOT and Burner Orifice TROUBLE- Shooting See CleaningMaintenance, Top Technical ServiceIng statement at Replacement Parts ServiceParts Under Warranty Parts Not Under WarrantyValve GA5010 Service Publications AccessoryParts Centrals Illustrated Parts Breakdown Parts ListKeep this Warranty Warranty Information