SPECIFICATIONS BTU (Variable)

5,500/11,000

Type Gas

Propane Only

Ignition

Piezo

Pressure Regulator Setting

8" W.C.

Inlet Gas Pressure (inches of water)

 

Maximum

14"

Minimum

11"

Dimensions, Inches (H x W x D)

 

Heater

20 1/2 x 13 1/2 x 5

Carton

25 x 16 11/16 x 7 1/2

Weight (pounds)

 

Heater

14

Shipping

17

SERVICE

When gas pressure is too low

 

HINTS

• pilot will not stay lit

• burner(s) will have delayed ignition

 

• heater will not produce specified heat

 

• propane gas supply may be low

 

When gas quality is bad

 

• pilot will not stay lit

 

• burner(s) will produce flames and soot

 

• heater will backfire when lit

 

You may feel your gas pressure is too low or gas quality is bad. If so, contact your

 

local propane gas supplier.

REPLACEMENT

Note: Use only original replacement parts. This will protect your warranty cover-

PARTS

age for parts replaced under warranty.

Parts Under Warranty

 

 

Contact authorized dealer from whom you purchased this product. If they cannot

 

supply original replacement part(s), call DESA International’s Technical Service

 

Department at 1-800-972-7879 for referral information.

When contacting your dealer or DESA International, have ready:

your name

your address

model number of your heater

how heater was malfunctioning

type of gas used (propane or natural gas)

purchase date

Usually, we will ask you to return the defective part to the factory.

Parts Not Under Warranty

Contact authorized dealers of this product. If they cannot supply original replace- ment part(s), call DESA International’s Parts Department at (502) 781-9600 for information.

When calling DESA International, have ready:

model number of your heater

the replacement part number

25

100846

Image 25
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualContents Safety Information Product Safety DeviceLocal Codes UnpackingCombustion Fresh AIR ForVentilation Producing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Fresh AIRDetermining if You Have a Confined or Unconfined Space Ventilation AIR Fresh AIR for Combustion and VentilationVentilation Air From Inside Building Ventilation Air From Outdoors Ventilation AIRInstallation Items Installing To WallCheck GAS Type Locating HeaterMarking Screw Locations Installing Heater to WallFolding Anchor Installing Two Mounting ScrewsPlacing Heater On Mounting Screws Qualified service person must connect heater to gas supply Connecting To GASSupply Follow all local codesChecking GAS Pressure Testing GAS Supply Piping SystemConnections Servicing. Correct all leaks at onceChecking Pressure Testing Heater GAS ConnectionsOperating Heater For Your Safety Read Before LightingPilot To Select Heating Level Inspecting HeaterBurner Pilot Flame PatternBurner Flame Pattern Inspecting BurnerODS/PILOT and Burner Orifice Trouble ShootingCabinet TROUBLE- Shooting See CleaningMaintenance, Ing statement at Technical ServiceTop Replacement Parts ServiceParts Under Warranty Parts Not Under WarrantyParts Centrals Service Publications AccessoryValve GA5010 Illustrated Parts Breakdown Parts ListKeep this Warranty Warranty Information