TROUBLE- SHOOTING
Continued
OBSERVED | POSSIBLE |
|
|
| ||
PROBLEM | CAUSE | REMEDY |
| |||
|
|
|
|
|
|
|
Burner(s) does not | 1. | Burner orifice(s) is | 1. | Clean burner orifice(s) |
| |
light after ODS/pilot |
| clogged |
| (see Cleaning and |
| |
is lit |
|
|
| Maintenance, page 21) |
| |
|
|
|
|
| or replace burner |
|
|
|
|
|
| orifice(s) |
|
|
| 2. | Burner orifice(s) | 2. | Replace burner orifice(s) |
|
|
|
| diameter is too small |
|
|
|
|
| 3. | Inlet gas pressure is | 3. | Contact local propane |
|
|
|
| too low |
| gas company |
|
|
|
|
|
|
|
|
Delayed ignition of | 1. | Manifold pressure is | 1. | Contact local propane |
| |
burner(s) |
| too low |
| gas company |
| |
|
| 2. | Burner orifice(s) is | 2. | Clean burner orifice(s) |
|
|
|
| clogged |
| (see Cleaning and |
|
|
|
|
|
| Maintenance, page 21) |
|
|
|
|
|
| or replace burner |
|
|
|
|
|
| orifice(s) |
|
|
|
|
|
|
|
|
Burner backfiring | 1. | Burner orifice(s) is | 1. | Clean burner orifice(s) |
| |
during combustion |
| clogged or damaged |
| (see Cleaning and |
| |
|
|
|
|
| Maintenance, page 21) |
|
|
|
|
|
| or replace burner |
|
|
|
|
|
| orifice(s) |
|
|
| 2. | Burner damaged | 2. | Replace burner |
|
|
| 3. | Gas regulator defective | 3. | Replace gas regulator |
|
|
|
|
|
|
| |
Burner plaque(s) does | 1. Plaque damaged | 1. | Replace burner |
| ||
not glow | 2. | Inlet gas pressure is | 2. | Contact local propane |
| |
|
|
| too low |
| gas company |
|
|
| 3. | Control knob set | 3. | Turn control knob until |
|
|
|
| between locked |
| it locks at desired setting |
|
|
|
| positions |
|
|
|
|
|
|
|
|
| |
Slight smoke or odor | 1. Residues from manu- | 1. | Problem will stop after a |
| ||
during initial opera- |
| facturing processes |
| few hours of operation |
| |
tion |
|
|
|
|
| |
|
|
|
|
|
| |
Heater produces a | 1. Metal expanding while | 1. | This is common with |
| ||
clicking/ticking noise |
| heating or contracting |
| most heaters. If noise is |
| |
just after burner is lit |
| while cooling |
| excessive, contact |
| |
or shut off |
|
|
| qualified service person |
|
Continued