Desa SVYD18N Installing, Check GAS Type, Minimum Wall and Ceiling Clearances see Figure

Page 8

INSTALLING

8

NOTICE

A qualified service person must install heater. Follow all local codes.

NOTICE

State or local codes may only allow operation of this appliance in a vented configuration. Check your state or local codes.

WARNING

WARNING ICON

G 001

Never install the heater

in a bedroom or bathroom

in a recreational vehicle

where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the heater

in high traffic areas

in windy or drafty areas

CAUTION

WARNING ICON

G 001

This heater creates warm air currents. These currents move heat to wall surfaces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities in the air (such as tobacco smoke) exist, may discolor walls.

IMPORTANT: Vent-free heaters add moisture to the air. Although this is benefi- cial, installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, pages 5 through 7.

CHECK GAS TYPE

Use only natural gas. If your gas supply is not natural gas, do not install heater. Call dealer where you bought heater for proper type heater.

CLEARANCES TO COMBUSTIBLES (Vent-Free Operation Only)

WARNING

WARNING ICON

G 001

Maintain the minimum clearances. If you can, provide greater clear- ances from floor, ceiling, and adjoining side and back walls.

Carefully follow the instructions below. This stove is a freestanding unit designed to set directly on the floor. IMPORTANT: You must maintain minimum wall and ceiling clearances during installation. The minimum clearances are shown in Figure 4, page 9. Measure from outermost point of stove top.

Minimum Wall and Ceiling Clearances (see Figure 4)

A.Clearances from outermost point of stove top to any combustible side wall should not be less than 12 inches.

B.Clearances from outermost point of stove top to any combustible back wall should not be less than 6 inches (Includes Corner Installations).

C.Clearances from the stove top to the ceiling should not be less than 48 inches.

104024

Image 8
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASContents Safety Information For use with this heater Local Codes Product Features Safety PilotOperation Piezo Ignition SystemProviding Adequate Ventilation AIR forVentilation Determining if You Have a Confined or Unconfined Space AIR for Combustion and VentilationDetermining AIR Flow for Heater Location Ventilation AIR Minimum Wall and Ceiling Clearances see Figure InstallingCheck GAS Type Stove Cavity Assembly Front ViewTop View Side ViewLaying Down Stove On Side Attaching Stove Legs Attaching Stove Door Installing Installing GAS LOG Heater Into Stove Placing Heater Base In Stove CavityConnecting to GAS Supply Installation Items NeededSide View Back View Checking GAS Connections Gas ConnectionPressure Testing Heater Gas Connections Test Pressures Equal To or Less Than 1/2 PsigFor Your Safety Read Before Lighting Operating HeaterMatch, see Manual Lighting Procedure on HeaterOperating Heater Inspecting Burners Pilot Flame PatternCleaning and Maintenance Trouble Shooting Turn off heater and let cool before cleaningODS/PILOT and Burner LogsMaintenance, TROUBLE- ShootingRefer to Air for Com Gas leak. See Warning Service ReplacementTechnical HintsIllustrated Parts Breakdown Parts List SCIVFC, Scivfb SCIVFG, Scivfr SCIVFC, Scivfb Accessory Valve GA5010104024 Warranty Information Keep this Warranty