Desa SVYD18N installation manual Gas leak. See Warning

Page 24

TROUBLE- SHOOTING

Continued

WARNING

WARNING ICON

G 001

If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time.

OBSERVED

POSSIBLE

 

PROBLEM

CAUSE

REMEDY

 

 

 

Heater produces a

1. Metal expanding while

1. This is common with

clicking/ticking noise

heating or contracting

most heaters. If noise is

just after burner is lit or

while cooling

excessive, contact

shut off

 

qualified service person

Heater produces

1.

Heater burning

vapors

unwanted odors

 

from

paint, hair

spray,

 

 

glues,

cleaners,

chemi-

 

 

cals, new carpet, etc. (See

 

 

IMPORTANT statement

 

 

above)

 

 

2.

Gas leak. See Warning

 

 

statement at top of

 

 

page

 

 

1.Open window and ventilate room. Stop using odor causing products while heater is running

2.Locate and correct all leaks (see Checking Gas Connections, page 16)

Heater shuts off in use

1.

Not enough fresh air is

1.

Open window and/or

(ODS operates)

 

available

 

door for ventilation

 

2.

Low line pressure

2.

Contact local natural

 

 

 

 

gas company

 

3.

ODS/pilot is partially

3.

Clean ODS/pilot (see

 

 

clogged

 

Cleaning and Mainte-

 

 

 

 

nance, page 21)

 

 

 

 

 

 

Gas odor even when

1.

Gas leak. See Warning

1.

Locate and correct all

control knob is in OFF

 

statement at top of

 

leaks (see Checking Gas

position

 

page

 

Connections, page 16)

 

2.

Control valve defective

2.

Replace control valve

 

 

 

 

Gas odor during

1.

Foreign matter between

1. Take apart gas tubing and

combustion

 

control valve and burner

 

remove foreign matter

 

2.

Gas leak. See Warning

2.

Locate and correct all

 

 

statement at top of

 

leaks (see Checking Gas

 

 

page

 

Connections, page 16)

24

104024

Image 24
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASContents Safety Information For use with this heater Local Codes Product Features Safety PilotOperation Piezo Ignition SystemAIR for VentilationProviding Adequate Ventilation AIR for Combustion and Ventilation Determining AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Installing Check GAS TypeMinimum Wall and Ceiling Clearances see Figure Stove Cavity Assembly Front ViewTop View Side ViewLaying Down Stove On Side Attaching Stove Legs Attaching Stove Door Installing Installing GAS LOG Heater Into Stove Placing Heater Base In Stove CavityConnecting to GAS Supply Installation Items NeededSide View Back View Checking GAS Connections Gas ConnectionPressure Testing Heater Gas Connections Test Pressures Equal To or Less Than 1/2 PsigFor Your Safety Read Before Lighting Operating HeaterMatch, see Manual Lighting Procedure on HeaterOperating Heater Inspecting Burners Pilot Flame PatternCleaning and Maintenance Trouble Shooting Turn off heater and let cool before cleaningODS/PILOT and Burner LogsMaintenance, TROUBLE- ShootingRefer to Air for Com Gas leak. See Warning Service ReplacementTechnical HintsIllustrated Parts Breakdown Parts List SCIVFC, Scivfb SCIVFG, Scivfr SCIVFC, Scivfb Accessory Valve GA5010104024 Warranty Information Keep this Warranty