INSTALLING | Minimum Non Combustible Material Clearances |
|
|
| ||||||||||||
If Using Mantel |
|
|
|
|
|
|
|
|
|
|
|
| ||||
Continued |
|
|
|
|
|
|
|
|
|
|
|
| ||||
You must have non combustible material(s) above the fireplace opening. Non | ||||||||||||||||
| ||||||||||||||||
| combustible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch | |||||||||||||||
| thick. With sheet metal, you must have non combustible material behind it. Non | |||||||||||||||
| combustible material must extend at least 8 inches up (for all models). If non | |||||||||||||||
| combustible material is less than 12", you must install the fireplace hood accessory | |||||||||||||||
| (24" and 30" models only). Even if non combustible material is more than 12", you | |||||||||||||||
| may need the hood accessory to deflect heat away from your mantel shelf. See | |||||||||||||||
| chart below and Figures 6 and 7 for minimum clearances. |
|
|
| ||||||||||||
| IMPORTANT: If you cannot meet these minimum clearances, you must operate | |||||||||||||||
| heater with chimney flue damper open. Go to Installing Damper Clamp Accessory | |||||||||||||||
| for Vented Operation, page 13. |
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
| |||||||||
|
|
| Requirements for |
|
|
| ||||||||||
|
| Material Distance (A) |
| Safe Installation |
|
|
| |||||||||
|
|
|
|
|
|
|
| |||||||||
|
| 12" or more |
|
|
| Non combustible material OK. |
| |||||||||
|
| Between 8" and 12" |
| 24" or 30" Models: Install fireplace hood |
| |||||||||||
|
|
|
|
|
|
| acessory (GA6050 or GA6052, see |
| ||||||||
|
|
|
|
|
|
| Accessories, page 33). |
|
|
| ||||||
|
|
|
|
|
|
| 18" Model: Non combustible material OK. |
| ||||||||
|
| Less than 8" |
|
|
| Non combustible material must be |
| |||||||||
|
|
|
|
|
|
| extended to at least 8". See Between 8" |
| ||||||||
|
|
|
|
|
|
| and 12", above. If you cannot extend |
| ||||||||
|
|
|
|
|
|
| material, you must operate heater with |
| ||||||||
|
|
|
|
|
|
| flue damper open. |
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| Mantel Clearances |
|
|
|
|
|
|
|
|
|
|
|
| |||
| If you meet minimum clearance between mantel shelf and top of fireplace opening, | |||||||||||||||
| a hood is not required (see Figure 6). | Mantel Shelf |
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
| 10" |
|
|
|
|
|
|
| Underside of | ||||
|
|
|
| 8" |
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
| Mantel Shelf | ||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
| 6" |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
| 2 1/2" |
|
|
|
|
|
|
|
| All minimum | |||
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
| distances are | ||
| Minimum Non- |
|
| (A) |
|
|
|
|
|
|
| in inches | ||||
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
| |||||
| Combustible |
|
|
|
|
|
|
|
| Log Set | ||||||
|
|
|
|
|
|
|
|
|
|
| ||||||
| Material |
|
|
|
|
|
|
|
|
|
| |||||
|
| 12" |
|
| 20" |
| 241/2" | 271/2" | 30" |
| 24"/30" Models | |||||
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
| 8" |
|
| 14" |
| 163/4" | 181/2" | 20" |
| 18" Model | ||
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| Top of Fireplace | |||
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
| Opening | |||
|
|
|
| Minimum Non- | Distances to |
|
|
| ||||||||
|
|
|
| Combustible |
|
| Underside of |
|
|
| ||||||
|
|
|
| Material Height | Mantel |
|
|
|
Figure 6 - Minimum Mantel Clearances Without Using Hood
If above minimum clearances are not met, you must have a hood. Follow | |
minimum clearances shown in Figure 7 when using hood. | Continued 11 |
101308