Desa NATURAL GAS LOG HEATER installation manual Operating Heater

Page 22

OPERATING HEATER

Manually-Controlled Models

22

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING

WARNING ICON

G 001

If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

WARNING

WARNING ICON

G 001

If fireplace has glass doors, never operate this heater with glass doors closed. If you operate heater with doors closed, heat buildup inside fireplace will cause glass to burst. Also if fireplace opening has vents at the bottom, you must open the vents before operating heater.

You must operate this heater with a fireplace screen in place. Make sure fireplace screen is closed before running heater.

NOTICE

During initial operation of new heater, burning logs will give off a paper- burning smell. Orange flame will also be present. Open damper or window to vent smell. This will only last a few hours.

Note: Homeowners generally prefer to operate their heater with the chimney damper closed. This will put all the heat into the room. However there may be times you will desire the full flames of the High heat setting but will find the heat output excessive. You can open the chimney damper (if you have one) fully or partially to release some of the heat. WARNING: Damper handle will be hot if heater has been running.

1.STOP! Read the safety information above.

2.Make sure manual shutoff valve is fully open.

3. Press in and turn control knob clockwise

Clockwise

to the OFF position.

 

 

 

Ignitor Button

 

 

Control Knob

 

 

 

 

 

HI

PILOT

 

 

 

OFF

 

 

LO

 

Figure 22 - Control Knob and Ignitor Button Location

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information above. If you don’t smell gas, go to the next step.

101308

Image 22
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASContents Safety Information Safety InformationProduct Identification Local Codes Unpacking Product FeaturesSafety Device OperationVentilation AIR for CombustionProviding Adequate Ventilation Determining AIR Flow for Heater Location AIR for Combustion and VentilationDetermining if You Have a Confined or Unconfined Space Combustion AIR forVentilation AIR Installing Check GAS TypeAnces from floor, ceiling, and adjoining wall To Combustible MaterialsLOG Sizing Requirements Minimum Wall and Ceiling Clearances see FigureAccessories, Minimum Non Combustible Material ClearancesInstalling For Vented Operation,Floor Clearances Installing Damper Clamp Accessory for Vented Operation Attaching Damper ClampInstalling Heater Base Assembly Installation Items NeededAttaching Flexible Gas Hose to Heater Gas Regulator Connecting to GAS Supply Installation Items NeededChecking GAS Connections Gas ConnectionPressure Testing Heater Gas Connections Test Pressures Equal To or Less Than 1/2 PsigInstalling Logs Installing Front LogFor Your Safety Read Before Lighting Operating HeaterHeater OperatingThermostat-Controlled Models Only Operating Heater Models Pilot Flame Pattern Inspecting BurnersFront Burner Flame Pattern ODS/PILOT and Burners Trouble ShootingLogs Cleaning and Mainte TROUBLE- ShootingTrouble Gas leak. See Warning Positioning OptionalSensing Bulb Optional Positioning Thermostat Sensing Bulb For Masonry Factory-built Metal FireplaceTechnical ServiceService HintsParts Under Warranty Replacement PartsParts Not Under Warranty Hood GA6050 AccessoriesValve GA5010 Hood GA6052Illustrated Parts Break Down Parts List Description QTYThermostat Controlled Models Parts List 101308 101308 Warranty Information Keep this Warranty