Desa NATURAL GAS LOG HEATER installation manual TROUBLE- Shooting, Cleaning and Mainte

Page 26

TROUBLE- SHOOTING

OBSERVED

POSSIBLE

 

PROBLEM

CAUSE

REMEDY

 

 

 

Continued

When ignitor button is pressed, there is spark at ODS/pilot but no ignition

1.Gas supply turned off or manual shutoff valve closed

2.Control knob not in PILOT position

3.Control knob not pressed in while in PILOT position

4.Air in gas lines when installed

5.ODS/pilot is clogged

6.Gas regulator setting is not correct

1.Turn on gas supply or open manual shutoff valve

2.Turn control knob to PILOT position

3.Press in control knob while in PILOT position

4.Continue holding down control knob. Repeat igniting operation until air is removed

5.Clean ODS/pilot (see Cleaning and Mainte- nance, page 25) or replace ODS/pilot assembly

6.Replace gas regulator

26

ODS/pilot lights but

1.

Control knob not fully

1.

Press in control knob

flame goes out when

 

pressed in

 

fully

control knob is

2.

Control knob not

2.

After ODS/pilot lights,

released

 

pressed in long enough

 

keep control knob

 

 

 

 

pressed in 30 seconds

 

3.

Safety interlock system

3.

Wait one minute for

 

 

has been triggered

 

safety interlock system

 

 

 

 

to reset. Repeat ignition

 

 

 

 

operation

 

4.

Manual shutoff valve

4.

Fully open manual shut-

 

 

not fully open

 

off valve

 

5.

Pilot flame not touching

5.

A) Contact local natural

 

 

thermocouple, which

 

gas company

 

 

allows thermocouple to

 

 

 

 

cool, causing pilot flame

 

B) Clean ODS/pilot (see

 

 

to go out. This problem

 

Cleaning and Mainte-

 

 

could be caused by one

 

nance, page 25) or

 

 

or both of the following:

 

replace ODS/pilot

 

 

A) Low gas pressure

 

assembly

 

 

B) Dirty or partially

 

 

 

 

clogged ODS/pilot

 

 

 

6.

Thermocouple connec-

6.

Hand tighten until snug,

 

 

tion loose at control

 

then tighten 1/4 turn

 

 

valve

 

more

 

7.

Thermocouple damaged

7.

Replace thermocouple

 

8.

Control valve damaged

8.

Replace control valve

101308

Image 26
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASContents Safety Information Safety InformationProduct Identification Local Codes Unpacking Product FeaturesSafety Device OperationProviding Adequate Ventilation AIR for CombustionVentilation Determining if You Have a Confined or Unconfined Space AIR for Combustion and VentilationDetermining AIR Flow for Heater Location Ventilation AIR AIR forCombustion Installing Check GAS TypeAnces from floor, ceiling, and adjoining wall To Combustible MaterialsLOG Sizing Requirements Minimum Wall and Ceiling Clearances see FigureAccessories, Minimum Non Combustible Material ClearancesInstalling For Vented Operation,Floor Clearances Installing Damper Clamp Accessory for Vented Operation Attaching Damper ClampInstalling Heater Base Assembly Installation Items NeededAttaching Flexible Gas Hose to Heater Gas Regulator Connecting to GAS Supply Installation Items NeededChecking GAS Connections Gas ConnectionPressure Testing Heater Gas Connections Test Pressures Equal To or Less Than 1/2 PsigInstalling Logs Installing Front LogFor Your Safety Read Before Lighting Operating HeaterThermostat-Controlled Models Only OperatingHeater Operating Heater Models Front Burner Flame Pattern Inspecting BurnersPilot Flame Pattern Logs Trouble ShootingODS/PILOT and Burners Cleaning and Mainte TROUBLE- ShootingTrouble Gas leak. See Warning Sensing Bulb OptionalPositioning Optional Positioning Thermostat Sensing Bulb For Masonry Factory-built Metal FireplaceTechnical ServiceService HintsParts Not Under Warranty Replacement PartsParts Under Warranty Hood GA6050 AccessoriesValve GA5010 Hood GA6052Illustrated Parts Break Down Parts List Description QTYThermostat Controlled Models Parts List 101308 101308 Warranty Information Keep this Warranty