Quadra-Fire 31M-ACC-NT, 31ST-ACC, 31M-ACC-GT Wood Stove Series ACC Outside Air Kit Installation

Page 14

R

3100 Wood Stove Series (ACC)

B. Outside Air Kit Installation

A source of air (oxygen) is necessary in order for combus- tion to take place. Whatever combustion air is consumed by the fire must be replaced. Air is replaced via air leak- age around windows and under doors. In homes that have tightly sealed doors and windows, an outside air source is needed. An optional Outside Air Kit is available.

Included in OAK-ACC: Termination cap, (2) wire ties, flex adapter, and fasteners

Included in SRV7033-041:Cover plate and sealing rope (see Floor Installation Alternative below, Figure 14.2)

Items Needed for Installation (not supplied)

4 inch flex aluminum pipe, or if using alternate material, then it shall be made from durable, non-combustible, heat resistant material up to 350oF. Cut the pipe to the required length for your installation.

Phillips head screw driver

Silicone sealant

Drills and saws necessary for cutting holes through the wall or flooring in your home.

WARNING

Fire Risk.

Asphyxiation Risk.

Do not draw outside combustion air from:

Wall, floor or ceiling cavity

Enclosed space such as an attic or garage

Close proximity to exhaust vents or chimneys

Fumes or odor may result

WARNING

Asphyxiation Risk.

Outside air inlet must be located to prevent block- age from:

Leaves

Snow or ice

Other debris

Block may cause combustion air starvation

Smoke spillage may set off alarms or irritate sensi- tive individuals.

1.Remove all materials from packing box.

2.Using a #2 Phillips screw driver attach the flex adapter to the stove using 4 screws. Figure 14.1

3.Remove circular” knock-out” in the base of the pedestal.

4.Floor & Rear Installation: Cut a 4 inch (102mm) hole in outside wall or floor to accommodate outside air piping. Use 4 inch (102mm) aluminum metal flex or rigid piping to directly connect outside air to appliance intake. Use the supplied termination cap with a rodent screen. Seal between the wall (or floor) and the pipe with silicone to prevent moisture penetration.

WARNING

Asphyxiation Risk.

Length of outside air supply duct shall NOT exceed the length of the vertical height of the exhaust flue.

Fire will not burn properly

Smoke spillage occurs when door is opened due to air starvation.

5.Floor Installation Alternative: In some instances you may not be able to install the flex pipe as show in Figure

14.1.If that is the case, you will need to order SRV7033- 041 which includes a cover plate and sealing rope as shown in Figure 14.2. The goal is to seal the pedestal so no room air can leak into the pedestal.

Flex Adapter

Wire Tie

Terminatio

Cap

Remove circular

“knock-out” in base of pedestal.

Flex Line

Wire Tie

Rope to Seal Pedestal

Cover

Plate

Figure 14.1 - Floor & Rear Installation

Figure 14.2 - Floor Installation Alternative

Page 14

7033-277C

March 2, 2007

Image 14
Contents Fire Risk Step Top Uni-Body Model Millennium ModelPedestal Model Shown Wood Stove Series ACC Welcome to the Quadra-Fire FamilyTable of Contents Appliance Certification Listing and Code ApprovalsBTU & Efficiency Specifications Mobile Home ApprovedAsphyxiation Risk Fire SafetyService / Maintenance Tip Any such action that may cause a fire hazard Fire RiskAppliance needs to draft properly for safety Wood Stove Series ACC Negative PressureTools And Supplies Needed Wood Stove Series ACC Flue Draft ConsiderationsVenting Systems Inspect Appliance & Components and Pre-Use Check ListWood Stove Series ACC Typical Stove Systems Masonry ChimneyMillennium Model 3Dimensions and ClearancesAppliance Dimensions 34-1/4 in mm 457mm 14-15/16 19-1/16 in.379mm 484mm 33-1/8 Wood Stove Series ACC Clearances to Combustibles UL and ULC Double Wall PipeMillennium Model InstallationHearth Protection Requirements See FigureWood Stove Series ACC Step-Top Uni-Body Model Fire Risk Asphyxiation Risk Wood Stove Series ACC Outside Air Kit InstallationItems Needed for Installation not supplied Wood Stove Series ACC Blower Optional Shock Risk5Chimney Requirements Venting Components Chimney SystemsInstructions ComponentsAir Clearances Solid Pack Chimney with Metal Supports as a ThimbleChimney Height / Rise and Run Installing Chimney ComponentsSolid Pack Chimney with Metal Supports as a Thimble Cont’d Wood Stove Series ACC Chimney Termination Requirements RuleMobile Home Installation Part SRV7033-041 for installation in a mobile Home7Appliance Set Up Begin installing the ARS SystemStep Top model with a pedestal assembly you must attach Installing Pedestal AssemblyFinishing the ARS Installation Installing Leg Kit Attach the 2 bottom screws of the mounting brackets toWood Stove Series ACC Door Handle Assembly Adjusting The Blower Speed ControlWood Selection & Storage Operating InstructionsBurning Process Kindling or First StageAutomatic Combustion Control ACC Air ControlsBurn Rates and Operating Efficiency Wood Stove Series ACC Building a Fire Opacity Smoke Initial cold start-up and all Burn SettingsWood Stove Series ACC Blower Operating Instructions OverfiringWood Stove Series ACC Frequently Asked Questions Issues SolutionsARS Operating and Cleaning General MaintenanceCreosote Chimney Cleaning Disposal of AshesCleaning Plated Surfaces Glass ReplacementGlass Cleaning Fire Risk Injury RiskWood Stove Series ACC Firebrick Replacement Brick Size QtyWood Stove Series ACC Baffle Removal Snap Disc Replacement BaffleReplacing Tube Channel Assembly Wood Stove Series ACC Tube Channel Assembly ReplacementRemoving Tube Channel Assembly Troubleshooting Diagnostic Question Possible Causes of Condition SolutionsDon’t get enough/any heat. What can I do about it? Reference Materials Exploded viewSizes Step Top Uni-Body Model Wood Stove Series ACC Service Parts & Accessories Item # AccessoriesItem # Service Parts Item # Service Parts Wood Stove Series ACC Service And Maintenance Log Date of Service Performed By Description of ServiceWood Stove Series ACC Homeowner’s Notes Wood Stove Series ACC Homeowner’s Notes Cont’d Lifetime Warranty Wood Stove Series ACC Warranty PolicyWood Stove Series ACC Contact Information