Quadra-Fire QV36A-FB owner manual Electrical Information, Recommendation for Wire

Page 31

10 Electrical Information

A. Recommendation for Wire

This appliance requires 110-120 VAC be wired to the junction box either for use of optional accessories or for proper operation of the appliance.

Note: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA 70-latest edition or the Canadian Electric Code, CSA C221.1.

A 110-120 VAC circuit for this product must be protected with ground-fault circuit-interrupter protection, in compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks.

B. Connecting to the Appliance

C. IntelliFire Ignition System Wiring

This appliance requires a 110 VAC supply to the appli- ance junction box for operation. A wiring diagram is shown in Figure 10.1.

This appliance is equipped with an IntelliFire control valve which operates on a 3 volt system.

This appliance is supplied with a battery pack and a 3 volt AC transformer, which requires the installation of the sup- plied junction box. It is highly recommended that the junc- tion box be installed at this time to avoid reconstruction.

The battery pack requires two D cell batteries (not includ- ed). Batteries cannot be placed in the battery pack while using the 3 volt AC transformer. Conversely, the trans- former must be unplugged if the battery pack is used.

WARNING

Wire 110V to electrical junction box.

Do NOT wire 110V to valve.

Do NOT wire 110V to wall switch.

Incorrect wiring will damage millivolt valves.

Uninterrupted or continuous power is required at all times in IPI system EXCEPT when using battery back-up.

Incorrect wiring will override IPI safety lockout and may cause explosion.

CAUTION

Battery polarity must be correct or module damage will occur.

WIRES WITH LABEL “FOR USE WITH REMOTE OR WALL SWITCH ONLY” (LOCATED UNDER FIREPLACE)

GREEN

ORANGE

BATTERIES

BLACK

RED

YELLOW (HNG)

 

 

 

WHITE (HTL)

RED

 

BATTERY

 

 

 

 

REAR VIEW

IPI VALVE

GROUND BLACK

BLACK

RED

GREEN

 

FLAME SOLENOID

RED (FEMALE/MALE)

1

2

IPI 3 MODULE 45 6 7 8

RED (MALE/FEMALE)

FLAME ON

RED

 

RED

 

 

IPI PILOT

BROWN

 

BROWN

 

BROWN

BROWN

 

 

 

RED

 

3V DC

BLACK

 

 

ORANGE

G Y R

G

Y

R

FRONT VIEW

FLAME HIGH/LOW

AC

ORANGE

ADAPTER WIRES

 

PLUG

BLACK

 

 

BLACK

 

 

GROUND

 

AUX

PIGTAIL

FIREBOX LIGHTS

CONNECTION

GREEN

YELLOW FACTORY

YELLOW CONNECTED TOGETHER

FAN THERMOSTAT

FAN

CONNECTION

BLACK

WHITE

GROUND

CONTINUOUS 110VAC

SUPPLY

Figure 10.1 IntelliFire Pilot Ignition (IPI) Wiring Diagram

HOT

 

 

TRANS

REM/AUX

FAN

NEUTRAL

 

 

Note 1: Ignition module, valve, pilot and wall switch operate on 3 volts.

Note 2: Plug QWSK-MLT wall switch kit into the REM/AUX outlet on the junction box.

Quadra-Fire • Expression 36 (QV36A-FB)2062-900 Rev. S • 11/11

31

Image 31
Contents What to do if you smell gas Model Expression 36 QV36A-FBHot glass will cause burns Homeowner Reference Information CongratulationsTable of Contents Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsInspect Appliance and Components Design and Installation ConsiderationsGetting Started Tools and Supplies NeededInspect Firebox 41-1/2 17-1/4 45-1/4 QV36A-FB Framing and ClearancesSelecting Appliance Location ModelFire Risk Odor Risk Constructing the Appliance ChaseClearances Mantel Projections17-1/4 41-1/2 32-1/2 Clearance to Combustibles254 1321 438 1054 825 914 Vent Termination Minimum Clearances Termination LocationsSee .4 for specific clearances Covered Alcove Applications Use of Elbows Vent Information and DiagramsVent Table Key Measuring Standards2 ft Vent DiagramsTop Vent Horizontal Termination One Elbow Two Elbows Minimum MaximumVT Min HT Max Top Vent Horizontal Termination Three ElbowsMust be installed prior to attaching a 90 elbow Extended to 40 feet Top Vent Vertical Termination Three ElbowsMin Max Feet then the total vent run can beCombustible Wall Penetration Vent Clearances and FramingPipe Clearances to Combustibles Wall Penetration FramingInstalling Attic Shield Installing the Ceiling FirestopVertical Penetration Framing  B. Installing the Optional Heat-ZoneGas Kit Removing Non-combustible Facing Mate- rial AssemblyAppliance Preparation Fire Risk Prevent contact with sagging, loose insulation Securing and Leveling the ApplianceBacker 10 Complete Installation of Non-combustible Installing Non-combustible Facing MaterialAssembling Pipe Sections Installing Vent PipeAssembly of Vent Sections Attaching Vent to the Firebox AssemblyAssembling DVP-12A Slip Sections Assembling Minimum Installations MI SectionsSecuring the Vent Sections Vertical Sections Disassembly of Vent SectionsHorizontal Sections Important Notice Heat shields may not be field constructed Installing Heat Shield and Horizontal Termination CapInstalling the Horizontal Termination Cap Heat Shield Requirements for Horizontal TerminationRoof Pitch Min. Ft Installing Roof Flashing and Vertical Ter- mination CapFoot minimum in snow regions Sharp Edges Assembling and Installing Storm CollarPressure Natural Gas Propane Gas InformationFuel Conversions Gas Connection Gas PressuresHigh Altitude Installations Electrical Information Recommendation for WireTo Replace a Light Bulb Optional Accessories RequirementsQWSK-MLT Wall Switch Kit Introduction Installation precautionsOperating Instructions Installation instructions Determine locationWiring the wall switch For units with factory installed rocker switchSET Set Temperature Button Setting Flame Height/manifold pressureWall Switch Button Operation Temperature ButtonJunction Box Detail Junction Box InstallationFronts FinishingFacing Material Facing RequirementsEmber Placement Appliance SetupClean the Appliance AccessoriesPositioning the Logs Log Assembly LOGS-2062LOG #2 SRV2062-702 LOG #1 SRV2062-701LOG #3 SRV2062-703 LOG #5 SRV330-704 LOG #4 SRV330-706LOG #6 SRV340-705 Burner Removal Only for Servicing Glass AssemblyRemoving Glass Assembly Replacing Glass AssemblyGrilles and Trim Air Shutter SettingBefore Lighting Appliance Operating InstructionsFinal inspection by Lighting Appliance IPI IgnitionInitial Break-in Procedure Frequently Asked QuestionsAfter Appliance is Lit Noise, but spark may not be present at pilot hood TroubleshootingSymptom Possible Cause Corrective Action IntelliFire Ignition SystemCracked, damaged, or loose. Verify connection from sensor Maintaining and Servicing Appliance Inspect Maintenance Tasks Maintenance TasksReference Materials Appliance Dimension DiagramLocation Inches Millimeters DVP-AS2 Vent Components DiagramsDVP vent components Horizontal Termination CapRF6M RF12M Direct Vent Gas Fireplace Service PartsLog Set Assembly At DepotBe ordered from an authorized dealer #17 Valve AssemblyStocked Service Parts ListLimited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Do not Discard this Manual Contact Information

QV36A-FB specifications

The Quadra-Fire QV36A-FB is a remarkable direct vent gas fireplace that combines beauty, efficiency, and innovative technology to create a cozy ambiance in any home. This fireplace is designed for those seeking an aesthetically pleasing yet highly functional heating solution.

One of the standout features of the QV36A-FB is its impressive heating capacity. With the ability to produce up to 34,000 BTUs, it effectively warms spaces of various sizes, making it suitable for both small and large living areas. Its impressive efficiency rating maximizes heat output while minimizing gas consumption, ensuring that homeowners can enjoy warmth without the worry of excessive energy bills.

The QV36A-FB employs a direct venting system, allowing for safe and efficient operation. This system draws air from outside for combustion, which is particularly beneficial for maintaining indoor air quality. The use of direct venting minimizes the loss of heated air, ensuring maximum efficiency and comfort. It also features a versatile installation design that provides flexibility to fit various home layouts.

In terms of aesthetics, the Quadra-Fire QV36A-FB does not disappoint. The fireplace boasts a sleek, contemporary design, available in multiple finishes that easily complement any interior decor. Customers can choose from a variety of logs and ember beds to customize the appearance of the fire, creating a personalized focal point that enhances the ambiance of their living space.

Another significant feature is its advanced ignition system, which ensures reliable and hassle-free starting. The QV36A-FB is equipped with a convenient remote control option that allows users to adjust flame height and heat output with ease, providing exceptional comfort without the need to manually tend to the fire.

This fireplace also incorporates several safety mechanisms, including a flame sensor and a safety shut-off feature, ensuring worry-free operation for families with children or pets. The combination of elegance, efficiency, and state-of-the-art technology makes the Quadra-Fire QV36A-FB a preferred choice for homeowners seeking a premium gas fireplace solution.

In conclusion, the QV36A-FB is more than just a heat source; it is a stylish addition that enhances home aesthetics while delivering reliable warmth. With its impressive features and innovative technologies, it stands out as a dependable choice in the world of gas fireplaces.