Quadra-Fire QV36A-FB owner manual Junction Box Installation, Junction Box Detail

Page 35

BATTERY

 

OPERATION

 

SWITCH

 

CONTROL

 

BOX

 

“OFF”

“BATTERY ON”

POSITION

POSITION

 

Figure 10.5.

 

F. Junction Box Installation

If the box is being wired from the OUTSIDE of the appli- ance:

Remove the cover plate located on the outer shell - right side (see Figure 10.6).

Install the supplied Romex™ connector in the cover plate.

Feed the necessary length of wire through the connector.

Make all necessary wire connections and reattach the cover plate to the outer shell.

If the box is being wired from the INSIDE of the appliance:

Remove the screw attaching the junction box/receptacle to the outer shell, rotate the junction box inward to disengage it from the outer shell (see Figure 10.6).

Pull the electrical wires from outside the appliance through this opening into the valve compartment.

Feed the necessary length of wire through the connector.

Make all necessary wire connections to the junction box/ receptacle and reassemble the junction box/receptacle to the outer shell.

 

Romex

 

Connector

 

14/2WG

 

Cover Plate

 

outside firebox

WHT

 

BLK

 

WHT

 

BLK

Copper

 

GRN wire

ground attached

to GRN screw with

inside box

GRN wire

Note: Do NOT wire

110VAC to wall switch.

Figure 10.6 Junction Box Detail

 

Quadra-Fire • Expression 36 (QV36A-FB)2062-900 Rev. S • 11/11

35

Image 35
Contents Hot glass will cause burns Model Expression 36 QV36A-FBWhat to do if you smell gas Homeowner Reference Information CongratulationsTable of Contents Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsInspect Appliance and Components Design and Installation ConsiderationsGetting Started Tools and Supplies NeededInspect Firebox 41-1/2 17-1/4 45-1/4 QV36A-FB Framing and ClearancesSelecting Appliance Location ModelFire Risk Odor Risk Constructing the Appliance ChaseClearances Mantel Projections254 1321 438 1054 825 914 Clearance to Combustibles17-1/4 41-1/2 32-1/2 See .4 for specific clearances Termination LocationsVent Termination Minimum Clearances Covered Alcove Applications Use of Elbows Vent Information and DiagramsVent Table Key Measuring Standards2 ft Vent DiagramsTop Vent Horizontal Termination One Elbow Two Elbows Minimum MaximumVT Min HT Max Top Vent Horizontal Termination Three ElbowsMust be installed prior to attaching a 90 elbow Extended to 40 feet Top Vent Vertical Termination Three ElbowsMin Max Feet then the total vent run can beCombustible Wall Penetration Vent Clearances and FramingPipe Clearances to Combustibles Wall Penetration FramingVertical Penetration Framing Installing the Ceiling FirestopInstalling Attic Shield Appliance Preparation Removing Non-combustible Facing Mate- rial Assembly B. Installing the Optional Heat-ZoneGas Kit Backer Securing and Leveling the ApplianceFire Risk Prevent contact with sagging, loose insulation 10 Complete Installation of Non-combustible Installing Non-combustible Facing MaterialAssembling Pipe Sections Installing Vent PipeAssembly of Vent Sections Attaching Vent to the Firebox AssemblyAssembling DVP-12A Slip Sections Assembling Minimum Installations MI SectionsHorizontal Sections Disassembly of Vent SectionsSecuring the Vent Sections Vertical Sections Important Notice Heat shields may not be field constructed Installing Heat Shield and Horizontal Termination CapInstalling the Horizontal Termination Cap Heat Shield Requirements for Horizontal TerminationFoot minimum in snow regions Installing Roof Flashing and Vertical Ter- mination CapRoof Pitch Min. Ft Sharp Edges Assembling and Installing Storm CollarPressure Natural Gas Propane Gas InformationFuel Conversions Gas Connection Gas PressuresHigh Altitude Installations Electrical Information Recommendation for WireTo Replace a Light Bulb Optional Accessories RequirementsQWSK-MLT Wall Switch Kit Introduction Installation precautionsOperating Instructions Installation instructions Determine locationWiring the wall switch For units with factory installed rocker switchSET Set Temperature Button Setting Flame Height/manifold pressureWall Switch Button Operation Temperature ButtonJunction Box Detail Junction Box InstallationFronts FinishingFacing Material Facing RequirementsEmber Placement Appliance SetupClean the Appliance AccessoriesPositioning the Logs Log Assembly LOGS-2062LOG #3 SRV2062-703 LOG #1 SRV2062-701LOG #2 SRV2062-702 LOG #6 SRV340-705 LOG #4 SRV330-706LOG #5 SRV330-704 Burner Removal Only for Servicing Glass AssemblyRemoving Glass Assembly Replacing Glass AssemblyGrilles and Trim Air Shutter SettingBefore Lighting Appliance Operating InstructionsFinal inspection by Lighting Appliance IPI IgnitionAfter Appliance is Lit Frequently Asked QuestionsInitial Break-in Procedure Noise, but spark may not be present at pilot hood TroubleshootingSymptom Possible Cause Corrective Action IntelliFire Ignition SystemCracked, damaged, or loose. Verify connection from sensor Maintaining and Servicing Appliance Inspect Maintenance Tasks Maintenance TasksLocation Inches Millimeters Appliance Dimension DiagramReference Materials DVP-AS2 Vent Components DiagramsDVP vent components Horizontal Termination CapRF6M RF12M Direct Vent Gas Fireplace Service PartsLog Set Assembly At DepotBe ordered from an authorized dealer #17 Valve AssemblyStocked Service Parts ListLimited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Do not Discard this Manual Contact Information

QV36A-FB specifications

The Quadra-Fire QV36A-FB is a remarkable direct vent gas fireplace that combines beauty, efficiency, and innovative technology to create a cozy ambiance in any home. This fireplace is designed for those seeking an aesthetically pleasing yet highly functional heating solution.

One of the standout features of the QV36A-FB is its impressive heating capacity. With the ability to produce up to 34,000 BTUs, it effectively warms spaces of various sizes, making it suitable for both small and large living areas. Its impressive efficiency rating maximizes heat output while minimizing gas consumption, ensuring that homeowners can enjoy warmth without the worry of excessive energy bills.

The QV36A-FB employs a direct venting system, allowing for safe and efficient operation. This system draws air from outside for combustion, which is particularly beneficial for maintaining indoor air quality. The use of direct venting minimizes the loss of heated air, ensuring maximum efficiency and comfort. It also features a versatile installation design that provides flexibility to fit various home layouts.

In terms of aesthetics, the Quadra-Fire QV36A-FB does not disappoint. The fireplace boasts a sleek, contemporary design, available in multiple finishes that easily complement any interior decor. Customers can choose from a variety of logs and ember beds to customize the appearance of the fire, creating a personalized focal point that enhances the ambiance of their living space.

Another significant feature is its advanced ignition system, which ensures reliable and hassle-free starting. The QV36A-FB is equipped with a convenient remote control option that allows users to adjust flame height and heat output with ease, providing exceptional comfort without the need to manually tend to the fire.

This fireplace also incorporates several safety mechanisms, including a flame sensor and a safety shut-off feature, ensuring worry-free operation for families with children or pets. The combination of elegance, efficiency, and state-of-the-art technology makes the Quadra-Fire QV36A-FB a preferred choice for homeowners seeking a premium gas fireplace solution.

In conclusion, the QV36A-FB is more than just a heat source; it is a stylish addition that enhances home aesthetics while delivering reliable warmth. With its impressive features and innovative technologies, it stands out as a dependable choice in the world of gas fireplaces.