Quadra-Fire QV36A-FB owner manual Maintaining and Servicing Appliance

Page 48

15 Maintaining and Servicing Appliance

Although the frequency of appliance servicing and maintenance will depend on use and the type of installation, a qualified service technician should perform an appliance checkup at the beginning of each heating season.

WARNING

Risk of injury or property damage.

Before servicing:

Turn off gas.

Turn off electricity to appliance.

Disable remote control, if one is present.

Ensure appliance is completely cooled.

After servicing:

Replace any screen or barrier that was removed.

Reseal and reinstall any venting removed for servicing.

WARNING

Annual inspection by qualified technician recommended.

Check:

Condition of doors, surrounds and fronts.

Condition of glass, glass assembly and glass seal.

Obstructions of combustion and ventilation air.

Condition of logs.

Condition of firebox.

Burner ignition and operation.

Burner air shutter adjustment

Gas connections and fittings.

Obstructions of termination cap.

Clean:

Glass

Air passageways, grilles, control compartment

Burner, burner ports

Risk of:

Fire

Delayed ignition or explosion

Exposure to combustion fumes

Odors

CAUTION

Handle glass assembly with care.

Note: Clean glass after initial 3-4 hours operation.

Longer operation without cleaning glass may cause a permanent white film on glass.

When cleaning glass door:

Avoid striking, scratching or slamming glass.

Do NOT use abrasive cleaners.

Use a hard water deposit glass cleaner on white film.

Do NOT clean glass when hot.

Turn off appliance after 3-4 hours of operation and

ALLOW TO COOL.

Remove and clean glass assembly.

Replace glass assembly and operate appliance for additional 12 hours.

Refer to maintenance instructions.

WARNING

Inspect external vent cap regularly.

Ensure no debris blocks cap.

Combustible materials blocking cap may ignite.

Restricted air flow affects burner operation.

48

Quadra-Fire • Expression 36 (QV36A-FB)2062-900 Rev. S • 11/11

Image 48
Contents Model Expression 36 QV36A-FB What to do if you smell gasHot glass will cause burns Congratulations Homeowner Reference InformationTable of Contents Listing and Code Approvals Installation of Carbon Monoxide Detectors Requirements for the Commonwealth of MassachusettsDesign and Installation Considerations Getting StartedTools and Supplies Needed Inspect Appliance and ComponentsInspect Firebox Framing and Clearances Selecting Appliance LocationModel 41-1/2 17-1/4 45-1/4 QV36A-FBConstructing the Appliance Chase ClearancesMantel Projections Fire Risk Odor RiskClearance to Combustibles 17-1/4 41-1/2 32-1/2254 1321 438 1054 825 914 Termination Locations Vent Termination Minimum ClearancesSee .4 for specific clearances Covered Alcove Applications Vent Information and Diagrams Vent Table KeyMeasuring Standards Use of ElbowsVent Diagrams Top Vent Horizontal Termination One Elbow Two ElbowsMinimum Maximum 2 ftTop Vent Horizontal Termination Three Elbows VT Min HT MaxMust be installed prior to attaching a 90 elbow Top Vent Vertical Termination Three Elbows Min MaxFeet then the total vent run can be Extended to 40 feetVent Clearances and Framing Pipe Clearances to CombustiblesWall Penetration Framing Combustible Wall PenetrationInstalling the Ceiling Firestop Installing Attic ShieldVertical Penetration Framing Removing Non-combustible Facing Mate- rial Assembly  B. Installing the Optional Heat-ZoneGas KitAppliance Preparation Securing and Leveling the Appliance Fire Risk Prevent contact with sagging, loose insulationBacker Installing Non-combustible Facing Material 10 Complete Installation of Non-combustibleInstalling Vent Pipe Assembly of Vent SectionsAttaching Vent to the Firebox Assembly Assembling Pipe SectionsAssembling Minimum Installations MI Sections Assembling DVP-12A Slip SectionsDisassembly of Vent Sections Securing the Vent Sections Vertical SectionsHorizontal Sections Installing Heat Shield and Horizontal Termination Cap Installing the Horizontal Termination CapHeat Shield Requirements for Horizontal Termination Important Notice Heat shields may not be field constructedInstalling Roof Flashing and Vertical Ter- mination Cap Roof Pitch Min. FtFoot minimum in snow regions Assembling and Installing Storm Collar Sharp EdgesGas Information Fuel Conversions Gas ConnectionGas Pressures Pressure Natural Gas PropaneHigh Altitude Installations Recommendation for Wire Electrical InformationOptional Accessories Requirements QWSK-MLT Wall Switch Kit IntroductionInstallation precautions To Replace a Light BulbInstallation instructions Determine location Wiring the wall switchFor units with factory installed rocker switch Operating InstructionsSetting Flame Height/manifold pressure Wall Switch Button OperationTemperature Button SET Set Temperature ButtonJunction Box Installation Junction Box DetailFinishing Facing MaterialFacing Requirements FrontsAppliance Setup Clean the ApplianceAccessories Ember PlacementLog Assembly LOGS-2062 Positioning the LogsLOG #1 SRV2062-701 LOG #2 SRV2062-702LOG #3 SRV2062-703 LOG #4 SRV330-706 LOG #5 SRV330-704LOG #6 SRV340-705 Glass Assembly Removing Glass AssemblyReplacing Glass Assembly Burner Removal Only for ServicingAir Shutter Setting Grilles and TrimOperating Instructions Before Lighting ApplianceLighting Appliance IPI Ignition Final inspection byFrequently Asked Questions Initial Break-in ProcedureAfter Appliance is Lit Troubleshooting Symptom Possible Cause Corrective ActionIntelliFire Ignition System Noise, but spark may not be present at pilot hoodCracked, damaged, or loose. Verify connection from sensor Maintaining and Servicing Appliance Maintenance Tasks Inspect Maintenance TasksAppliance Dimension Diagram Reference MaterialsLocation Inches Millimeters Vent Components Diagrams DVP-AS2Horizontal Termination Cap DVP vent componentsRF6M RF12M Service Parts Log Set AssemblyAt Depot Direct Vent Gas Fireplace#17 Valve Assembly Be ordered from an authorized dealerService Parts List StockedLimited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Contact Information Do not Discard this Manual

QV36A-FB specifications

The Quadra-Fire QV36A-FB is a remarkable direct vent gas fireplace that combines beauty, efficiency, and innovative technology to create a cozy ambiance in any home. This fireplace is designed for those seeking an aesthetically pleasing yet highly functional heating solution.

One of the standout features of the QV36A-FB is its impressive heating capacity. With the ability to produce up to 34,000 BTUs, it effectively warms spaces of various sizes, making it suitable for both small and large living areas. Its impressive efficiency rating maximizes heat output while minimizing gas consumption, ensuring that homeowners can enjoy warmth without the worry of excessive energy bills.

The QV36A-FB employs a direct venting system, allowing for safe and efficient operation. This system draws air from outside for combustion, which is particularly beneficial for maintaining indoor air quality. The use of direct venting minimizes the loss of heated air, ensuring maximum efficiency and comfort. It also features a versatile installation design that provides flexibility to fit various home layouts.

In terms of aesthetics, the Quadra-Fire QV36A-FB does not disappoint. The fireplace boasts a sleek, contemporary design, available in multiple finishes that easily complement any interior decor. Customers can choose from a variety of logs and ember beds to customize the appearance of the fire, creating a personalized focal point that enhances the ambiance of their living space.

Another significant feature is its advanced ignition system, which ensures reliable and hassle-free starting. The QV36A-FB is equipped with a convenient remote control option that allows users to adjust flame height and heat output with ease, providing exceptional comfort without the need to manually tend to the fire.

This fireplace also incorporates several safety mechanisms, including a flame sensor and a safety shut-off feature, ensuring worry-free operation for families with children or pets. The combination of elegance, efficiency, and state-of-the-art technology makes the Quadra-Fire QV36A-FB a preferred choice for homeowners seeking a premium gas fireplace solution.

In conclusion, the QV36A-FB is more than just a heat source; it is a stylish addition that enhances home aesthetics while delivering reliable warmth. With its impressive features and innovative technologies, it stands out as a dependable choice in the world of gas fireplaces.