A. Before Lighting Appliance

This appliance has an IntelliFire ignition system.

CAUTION

If installing IntelliFire ignition battery backup:

Do not install batteries if the backup mode may not be used for extended time.

Batteries may leak.

Install batteries only when needed for power outage.

Before operating this appliance have a qualified tech- nician:

Remove all shipping materials from inside and/or underneath the firebox.

Review proper placement of logs, rockwool, lava rock, and vermiculite.

Check the wiring.

Check the air shutter adjustment.

Ensure that there are no gas leaks.

Ensure that the glass is sealed and in the proper position.

Ensure that the flow of combustion and ventilation air is not obstructed (front grilles and vent caps).

WARNING

Glass door must be in place when appliance is operating.

Risk of:

Combustion Fumes

Fire

Do NOT operate appliance with glass door removed.

Open viewing glass for servicing only.

Glass door MUST be in place and sealed before operating appliance.

Only use glass door certified for use with appliance.

Glass replacement should be done by qualified technician.

WARNING

HOT SURFACES!

Glass and other surfaces are hot during operation AND cool down.

Hot glass will cause burns.

DO NOT touch glass until it is cooled

NEVER allow children to touch glass

Keep children away

CAREFULLY SUPERVISE children in same room as fireplace.

Alert children and adults to hazards of high temperatures.

High temperatures may ignite clothing or other flammable materials.

Keep clothing, furniture, draperies and other flammable materials away.

This appliance has been supplied with an integral barrier to prevent direct contact with the fixed glass panel. DO NOT operate the appliance with the barrier removed.

Contact your dealer or Hearth & Home Technologies if the barrier is not present or help is needed to properly install one.

WARNING

Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the owner’s information manual provided with this appliance. For assistance or additional information consult a qualified installer, service agency or the gas supplier.

WARNING

Do NOT use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

Quadra-Fire • Expression 36 (QV36A-FB)2062-900 Rev. S • 11/11

43

Image 43
Contents What to do if you smell gas Model Expression 36 QV36A-FBHot glass will cause burns Homeowner Reference Information CongratulationsTable of Contents Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsInspect Appliance and Components Design and Installation ConsiderationsGetting Started Tools and Supplies NeededInspect Firebox 41-1/2 17-1/4 45-1/4 QV36A-FB Framing and ClearancesSelecting Appliance Location ModelFire Risk Odor Risk Constructing the Appliance ChaseClearances Mantel Projections17-1/4 41-1/2 32-1/2 Clearance to Combustibles254 1321 438 1054 825 914 Vent Termination Minimum Clearances Termination LocationsSee .4 for specific clearances Covered Alcove Applications Use of Elbows Vent Information and DiagramsVent Table Key Measuring Standards2 ft Vent DiagramsTop Vent Horizontal Termination One Elbow Two Elbows Minimum MaximumVT Min HT Max Top Vent Horizontal Termination Three ElbowsMust be installed prior to attaching a 90 elbow Extended to 40 feet Top Vent Vertical Termination Three ElbowsMin Max Feet then the total vent run can beCombustible Wall Penetration Vent Clearances and FramingPipe Clearances to Combustibles Wall Penetration FramingInstalling Attic Shield Installing the Ceiling FirestopVertical Penetration Framing  B. Installing the Optional Heat-ZoneGas Kit Removing Non-combustible Facing Mate- rial AssemblyAppliance Preparation Fire Risk Prevent contact with sagging, loose insulation Securing and Leveling the ApplianceBacker 10 Complete Installation of Non-combustible Installing Non-combustible Facing MaterialAssembling Pipe Sections Installing Vent PipeAssembly of Vent Sections Attaching Vent to the Firebox AssemblyAssembling DVP-12A Slip Sections Assembling Minimum Installations MI SectionsSecuring the Vent Sections Vertical Sections Disassembly of Vent SectionsHorizontal Sections Important Notice Heat shields may not be field constructed Installing Heat Shield and Horizontal Termination CapInstalling the Horizontal Termination Cap Heat Shield Requirements for Horizontal TerminationRoof Pitch Min. Ft Installing Roof Flashing and Vertical Ter- mination CapFoot minimum in snow regions Sharp Edges Assembling and Installing Storm CollarPressure Natural Gas Propane Gas InformationFuel Conversions Gas Connection Gas PressuresHigh Altitude Installations Electrical Information Recommendation for WireTo Replace a Light Bulb Optional Accessories RequirementsQWSK-MLT Wall Switch Kit Introduction Installation precautionsOperating Instructions Installation instructions Determine locationWiring the wall switch For units with factory installed rocker switchSET Set Temperature Button Setting Flame Height/manifold pressureWall Switch Button Operation Temperature ButtonJunction Box Detail Junction Box InstallationFronts FinishingFacing Material Facing RequirementsEmber Placement Appliance SetupClean the Appliance AccessoriesPositioning the Logs Log Assembly LOGS-2062LOG #2 SRV2062-702 LOG #1 SRV2062-701LOG #3 SRV2062-703 LOG #5 SRV330-704 LOG #4 SRV330-706LOG #6 SRV340-705 Burner Removal Only for Servicing Glass AssemblyRemoving Glass Assembly Replacing Glass AssemblyGrilles and Trim Air Shutter SettingBefore Lighting Appliance Operating InstructionsFinal inspection by Lighting Appliance IPI IgnitionInitial Break-in Procedure Frequently Asked QuestionsAfter Appliance is Lit Noise, but spark may not be present at pilot hood TroubleshootingSymptom Possible Cause Corrective Action IntelliFire Ignition SystemCracked, damaged, or loose. Verify connection from sensor Maintaining and Servicing Appliance Inspect Maintenance Tasks Maintenance TasksReference Materials Appliance Dimension DiagramLocation Inches Millimeters DVP-AS2 Vent Components DiagramsDVP vent components Horizontal Termination CapRF6M RF12M Direct Vent Gas Fireplace Service PartsLog Set Assembly At DepotBe ordered from an authorized dealer #17 Valve AssemblyStocked Service Parts ListLimited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Do not Discard this Manual Contact Information

QV36A-FB specifications

The Quadra-Fire QV36A-FB is a remarkable direct vent gas fireplace that combines beauty, efficiency, and innovative technology to create a cozy ambiance in any home. This fireplace is designed for those seeking an aesthetically pleasing yet highly functional heating solution.

One of the standout features of the QV36A-FB is its impressive heating capacity. With the ability to produce up to 34,000 BTUs, it effectively warms spaces of various sizes, making it suitable for both small and large living areas. Its impressive efficiency rating maximizes heat output while minimizing gas consumption, ensuring that homeowners can enjoy warmth without the worry of excessive energy bills.

The QV36A-FB employs a direct venting system, allowing for safe and efficient operation. This system draws air from outside for combustion, which is particularly beneficial for maintaining indoor air quality. The use of direct venting minimizes the loss of heated air, ensuring maximum efficiency and comfort. It also features a versatile installation design that provides flexibility to fit various home layouts.

In terms of aesthetics, the Quadra-Fire QV36A-FB does not disappoint. The fireplace boasts a sleek, contemporary design, available in multiple finishes that easily complement any interior decor. Customers can choose from a variety of logs and ember beds to customize the appearance of the fire, creating a personalized focal point that enhances the ambiance of their living space.

Another significant feature is its advanced ignition system, which ensures reliable and hassle-free starting. The QV36A-FB is equipped with a convenient remote control option that allows users to adjust flame height and heat output with ease, providing exceptional comfort without the need to manually tend to the fire.

This fireplace also incorporates several safety mechanisms, including a flame sensor and a safety shut-off feature, ensuring worry-free operation for families with children or pets. The combination of elegance, efficiency, and state-of-the-art technology makes the Quadra-Fire QV36A-FB a preferred choice for homeowners seeking a premium gas fireplace solution.

In conclusion, the QV36A-FB is more than just a heat source; it is a stylish addition that enhances home aesthetics while delivering reliable warmth. With its impressive features and innovative technologies, it stands out as a dependable choice in the world of gas fireplaces.