Quadra-Fire QVI35S Appliance Setup, Remove Shipping Materials, Clean the Appliance, Accessories

Page 20

11 Appliance Setup

A. Remove Shipping Materials

Remove shipping materials from inside or underneath the firebox.

B. Clean the Appliance

Clean/vacuum any sawdust that may have accumulated inside the firebox or underneath in the control cavity.

C. Accessories

Install approved accessories per instructions included with

Îaccessories. Contact your dealer for a list of approved ac- cessories. Refer to Section 16.

WARNING

Shock or fire risk.

Use ONLY optional accessories approved for this appliance.

Using non-listed accessories voids warranty.

Using non-listed accessories may result in a safety hazard.

Only Hearth & Home Technologies approved

accessories may be used safely.

D. Ember Placement

WARNING

Explosion Risk.

Follow ember placement instructions in manual.

Do NOT place embers directly over burner ports.

Replace ember material annually.

Improperly placed embers interferes with proper burner operation.

Placing the Ember Material

Ember material is shipped with this gas appliance. To place the ember material:

Embers CANNOT be placed directly over ports.

When placing Glowing Embers® onto the burner care should be taken so that the ports are not covered. Place the dime-size ember pieces near port holes in burner top, sides and front (see Figure 11.1). Failure to follow this procedure will likely cause lighting and sooting problems.

EMBER MATERIAL/BRAISES

Figure 11.1 Placement of Embers

Place Mystic Ember over burner surface and around base of burner. Do not cover any burner port holes. Use this material to give the appliance a realistic ash bed.

Save the remaining ember materials for use during appliance servicing. The embers provided should be enough for 3 to 5 applications.

20

Quadra-Fire • QVI30S, QVI35S • 340-901 Rev. i • 6/09

 

Image 20
Contents HOT Surfaces ModelsWhat to do if you smell gas Homeowner Reference Information XxxxxxxxTable of Contents Listing and Code Approvals Design and Installation Considerations Getting StartedTools and Supplies Needed Inspect Appliance and ComponentsMinimum Appliance Size Location Fireplace Size RequirementsMinimum Fireplace Opening Clearances Clearances to Mantels or other Combustibles above ApplianceTermination Locations Vent Termination Minimum ClearancesVent Information and Diagrams Vent Table KeyHorizontal Venting Measuring StandardsInstallation Preparation Venting Components Installing Vent Pipe and ApplianceConnecting Vent Pipe Placing, Securing and Leveling the Appliance Installing Adaptor and Termination Cap Factory Built Wood BurningDamper Flashing Kit Optional Class a PipeGas Pressures Gas InformationFuel Conversions Gas Connection High Altitude Installations Check for GAS LeaksWiring the Appliance ON/OFF SwitchElectrical Information Appliance RequirementsJunction Box Installation Optional AccessoriesFAN Junction BOX Finishing Mantel ProjectionsAppliance Setup Clean the ApplianceAccessories Ember PlacementRefractory Placement Models Supreme-XT, Grand-XTQVI30, QVI35, ADI60 Refractory from the packagingLog Set Assembly LOGS-QVI30 Positioning the LogsQuadra-Fire QVI30S, QVI35S 340-901 Rev. i 6/09 Quadra-Fire QVI30S, QVI35S 340-901 Rev. i 6/09 Log Set Assembly LOGS-QVI35 Quadra-Fire QVI30S, QVI35S 340-901 Rev. i 6/09 Glass Assembly Air Shutter SettingRemoving Glass Assembly Replacing Glass AssemblyBefore operating this appliance have a qualified technician Operating InstructionsBefore Lighting Appliance What to do if YOU Smell GAS Lighting ApplianceStanding Pilot Ignition After Appliance is Lit Initial Break-in ProcedureCheck Pilot Flame Appearance Frequently Asked Questions Issue SolutionsStanding Pilot Ignition System TroubleshootingSymptom Possible Causes Corrective Action Troubleshooting Symptom Possible Cause Corrective ActionMaintenance Tasks Maintaining and Servicing ApplianceInspect Maintenance Tasks Doors, SurroundsAppliance Dimension Diagram Reference MaterialsVent Kits Components Direct Vent Flex Liner KitsService Parts Part number list on followingService Parts At DepotLog Set Assembly QVI35SNGKS-QVI35 Standing Pilot Valve Assembly QVI30S, QVI35SLimited Lifetime Warranty Quadra-Fire QVI30S, QVI35S 340-901 Rev. i 6/09 Contact Information

QVI35S, QVI30S specifications

The Quadra-Fire QVI35S and QVI30S are two impressive gas stoves that exemplify modern heating technology while prioritizing efficiency and aesthetics. As part of Quadra-Fire's renowned lineup, both models provide homeowners with outstanding performance and quality design.

One of the primary features of the QVI35S and QVI30S is their high efficiency rating. These stoves boast an impressive efficiency of up to 85%, which means that the majority of the fuel used is converted into heat for your home. This not only translates to lower energy bills but also less frequent fuel replenishment, making them cost-effective and environmentally friendly choices for heating.

Both models feature Quadra-Fire’s innovative heat management system, which ensures even heat distribution throughout the room. This system allows for efficient use of the fire's energy, maximizing warmth and minimizing heat loss. The QVI35S is particularly suited for larger spaces, capable of heating areas up to 1,800 square feet, while the QVI30S is ideal for medium-sized rooms, heating areas of up to 1,500 square feet.

The aesthetics of the QVI35S and QVI30S cannot be overlooked. Both models come with a variety of customizable options including black, pewter, or gold finishes, allowing homeowners to match their stove with their interior decor. The large viewing window enhances the visual appeal, offering a stunning display of the flame and creating a cozy ambiance in any room.

In terms of performance, both models feature the advanced Direct Vent technology. This system ensures that combustion air is drawn from outside the home, which helps maintain excellent indoor air quality. Additionally, the balanced flue design directs exhaust gases safely outside, minimizing emissions.

The stoves also incorporate an easy-to-use control system. Users can quickly adjust the flame height and heat output, allowing for precise temperature control. This feature, combined with the built-in fan option, ensures that heat is circulated effectively, providing optimal comfort.

Easy maintenance is another advantage of the QVI35S and QVI30S. They are designed for simple cleaning, with removable components and an accessible ash pan. This user-friendly design ensures that maintaining your stove is hassle-free.

In conclusion, the Quadra-Fire QVI35S and QVI30S deliver a blend of efficiency, aesthetic appeal, and advanced technology. They provide reliable heating solutions, customizable designs, and user-friendly features, making them excellent additions to any home looking to stay warm and stylish.