Quadra-Fire QVI30S Air Shutter Setting, Removing Glass Assembly, Replacing Glass Assembly

Page 27

6

6

Log #6 (SRV330-706): Nest log #6 in the cut out area on the right side of log #1. The thinnest “arm” of log #6 rests on top of log #3.

G. Glass Assembly

WARNING

Handle glass doors with care.

Inspect the gasket to ensure it is undamaged.

Inspect the glass for cracks, chips or scratches.

Do NOT strike, slam or scratch glass.

Do NOT operate appliance with glass door removed, cracked, broken or scratched.

Replace glass door assembly as a complete appliance.

Removing Glass Assembly

The glass assembly fastens to the fireplace in four places. Two or four of the fastening mechanisms will be spring- loaded glass latches, depending on the model. An ex- ample of the glass latch is shown in Figure 11.5.

QVI30S

To release glass assembly, pull the two bottom spring- loaded latches forward and allow them to retract away from the glass assembly. Remove glass assembly by carefully pulling the bottom side of the glass assembly out first. Carefully slide the glass assembly outward and downward until the top tabs are disengaged from the slots.

QVI35S

To release glass assembly, pull the two bottom spring- loaded latches forward and allow them to retract away from the glass assembly. Slide the glass assembly outward and downward until the top latches disengage.

Replacing Glass Assembly

QVI30S

Tilt glass assembly toward fireplace and slide glass assembly up to engage top two tabs with the corresponding slots. Fasten the two bottom latches.

QVI35S

Tilt glass assembly toward fireplace and slide glass as- sembly upward to engage top latches. Verify top latches are fully engaged and then fasten the two bottom latches.

GLASS ASSEMBLY

BOTTOM LATCH

Figure 11.5 Glass Assembly

H. Air Shutter Setting

Optimal flame appearance is dependent on the air shutter setting. Adjustments should be made by a qualified technician.

Model

NG

LP

QVI35S

1/2 in.

Full Open (3/4 in.)

QVI30S

3/8 in.

Full Open (3/4 in.)

Quadra-Fire • QVI30S, QVI35S • 340-901 Rev. i • 6/09

27

 

Image 27
Contents Models What to do if you smell gasHOT Surfaces Xxxxxxxx Homeowner Reference InformationTable of Contents Listing and Code Approvals Inspect Appliance and Components Design and Installation ConsiderationsGetting Started Tools and Supplies NeededFireplace Size Requirements Minimum Fireplace OpeningMinimum Appliance Size Location Clearances to Mantels or other Combustibles above Appliance ClearancesVent Termination Minimum Clearances Termination LocationsMeasuring Standards Vent Information and DiagramsVent Table Key Horizontal VentingInstallation Preparation Installing Vent Pipe and Appliance Connecting Vent PipeVenting Components Placing, Securing and Leveling the Appliance Class a Pipe Installing Adaptor and Termination CapFactory Built Wood Burning Damper Flashing Kit OptionalGas Information Fuel Conversions Gas ConnectionGas Pressures Check for GAS Leaks High Altitude InstallationsAppliance Requirements Wiring the ApplianceON/OFF Switch Electrical InformationOptional Accessories Junction Box InstallationFAN Junction BOX Mantel Projections FinishingEmber Placement Appliance SetupClean the Appliance AccessoriesRefractory from the packaging Refractory PlacementModels Supreme-XT, Grand-XT QVI30, QVI35, ADI60Positioning the Logs Log Set Assembly LOGS-QVI30Quadra-Fire QVI30S, QVI35S 340-901 Rev. i 6/09 Quadra-Fire QVI30S, QVI35S 340-901 Rev. i 6/09 Log Set Assembly LOGS-QVI35 Quadra-Fire QVI30S, QVI35S 340-901 Rev. i 6/09 Replacing Glass Assembly Glass AssemblyAir Shutter Setting Removing Glass AssemblyOperating Instructions Before Lighting ApplianceBefore operating this appliance have a qualified technician Lighting Appliance Standing Pilot IgnitionWhat to do if YOU Smell GAS Initial Break-in Procedure Check Pilot Flame AppearanceAfter Appliance is Lit Issue Solutions Frequently Asked QuestionsTroubleshooting Symptom Possible Causes Corrective ActionStanding Pilot Ignition System Symptom Possible Cause Corrective Action TroubleshootingMaintaining and Servicing Appliance Maintenance TasksDoors, Surrounds Inspect Maintenance TasksReference Materials Appliance Dimension DiagramDirect Vent Flex Liner Kits Vent Kits ComponentsPart number list on following Service PartsAt Depot Service PartsQVI35S Log Set AssemblyNGKS-QVI35 QVI30S, QVI35S Standing Pilot Valve AssemblyLimited Lifetime Warranty Quadra-Fire QVI30S, QVI35S 340-901 Rev. i 6/09 Contact Information