Quadra-Fire QVI30S, QVI35S owner manual Vent Kits Components, Direct Vent Flex Liner Kits

Page 37

B. Vent Kits Components

Direct Vent Flex Liner Kits (see Figure 15.2)

LINK-DV30B: Masonry 3 inch flex liner kit. Sections expand

to 30 feet. Includes: two liners, termination cap, flashing, and link adapter.

LINK-DV4-30B: Masonry 3 inch flex liner kit. Sections

expand to 30 feet and 4 feet. Includes: two liners, termination cap, flashing, and link adapter.

LINK-DV30B

LINK-DV4-30B

Installation

Installation

TERMINATION

CAP

EXHAUST

AIR

VENT PIPE

WARNING:

DO NOT BLOCK

THIS PIPE END!

INLET AIR

VENT PIPE

OPTIONAL LINK-ZC-ADPB

FOR USE WITH CLASS A

WOODBURNING PIPE

Figure 15.2 Direct Vent Flex Liner Kits

Direct Vent Flex Liner Accessory Kits (see Figure 15.3)

Flash-Damp: Zero clearance damper flashing kit for use with LINK-DV30B or LINK-DV4-30B liner kits.

LINK-ZC-ADP: Zero clearance chimney adapter

SVRLINK-ADP: Adapter kit (colinear to coaxial 3 inches included in above kits).

FLEX3-30: One 3 inch flexible liner expands to 30 feet.

FLEX3-30/2: Two 3 inch flexible liners expands to 30 feet each.

FLEX-CNCT: Connector kit - 3 inch liner to 3 inch liner, one connector per kit.

FLASH-DAMP

LINK-ZC-ADP

SVRLINK-ADP

FLEX3-30

FLEX3-30/2

FLEX3-CNCT

Figure 15.3 Direct Vent Flex Liner Accessory Kits

Quadra-Fire • QVI30S, QVI35S • 340-901 Rev. i • 6/09

37

 

Image 37
Contents What to do if you smell gas ModelsHOT Surfaces Xxxxxxxx Homeowner Reference InformationTable of Contents Listing and Code Approvals Getting Started Design and Installation ConsiderationsTools and Supplies Needed Inspect Appliance and ComponentsMinimum Fireplace Opening Fireplace Size RequirementsMinimum Appliance Size Location Clearances to Mantels or other Combustibles above Appliance ClearancesVent Termination Minimum Clearances Termination LocationsVent Table Key Vent Information and DiagramsHorizontal Venting Measuring StandardsInstallation Preparation Connecting Vent Pipe Installing Vent Pipe and ApplianceVenting Components Placing, Securing and Leveling the Appliance Factory Built Wood Burning Installing Adaptor and Termination CapDamper Flashing Kit Optional Class a PipeFuel Conversions Gas Connection Gas InformationGas Pressures Check for GAS Leaks High Altitude InstallationsON/OFF Switch Wiring the ApplianceElectrical Information Appliance RequirementsOptional Accessories Junction Box InstallationFAN Junction BOX Mantel Projections FinishingClean the Appliance Appliance SetupAccessories Ember PlacementModels Supreme-XT, Grand-XT Refractory PlacementQVI30, QVI35, ADI60 Refractory from the packagingPositioning the Logs Log Set Assembly LOGS-QVI30Quadra-Fire QVI30S, QVI35S 340-901 Rev. i 6/09 Quadra-Fire QVI30S, QVI35S 340-901 Rev. i 6/09 Log Set Assembly LOGS-QVI35 Quadra-Fire QVI30S, QVI35S 340-901 Rev. i 6/09 Air Shutter Setting Glass AssemblyRemoving Glass Assembly Replacing Glass AssemblyBefore Lighting Appliance Operating InstructionsBefore operating this appliance have a qualified technician Standing Pilot Ignition Lighting ApplianceWhat to do if YOU Smell GAS Check Pilot Flame Appearance Initial Break-in ProcedureAfter Appliance is Lit Issue Solutions Frequently Asked QuestionsSymptom Possible Causes Corrective Action TroubleshootingStanding Pilot Ignition System Symptom Possible Cause Corrective Action Troubleshooting Maintaining and Servicing Appliance Maintenance TasksDoors, Surrounds Inspect Maintenance TasksReference Materials Appliance Dimension DiagramDirect Vent Flex Liner Kits Vent Kits ComponentsPart number list on following Service PartsAt Depot Service PartsQVI35S Log Set AssemblyNGKS-QVI35 QVI30S, QVI35S Standing Pilot Valve AssemblyLimited Lifetime Warranty Quadra-Fire QVI30S, QVI35S 340-901 Rev. i 6/09 Contact Information