Quadra-Fire QVI30S Lighting Appliance, Standing Pilot Ignition, What to do if YOU Smell GAS

Page 29

B. Lighting Appliance

Standing Pilot Ignition

FOR YOUR SAFETY

READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

LIGHTING

INSTRUCTIONS

1.Turn off all electric power to the appliance.

2.Push in gas control knob slightly and turn clockwise to “OFF”.

A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B. BEFORE LIGHTING, smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas sup- plier, call the fire department.

C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explo- sion.

D. Do not use this appliance if any part has been under water. Im- mediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

NOTE: Knob cannot be turned from “PILOT” to “OFF” unless knob is pushed in slightly. Do not force.

3.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the Safety Informa- tion located on the left side of this label. If you don’t smell gas, go to next step.

4.Find the pilot. The pilot is inside combustion chamber next to the main burner.

5.Turn knob on gas control counter clockwise

to “PILOT”.

6. Push in control knob all the way and hold in. Im-

mediately depress red or black piezo button. It may

require several depressions of the red or black

piezo button until PILOT lights. If PILOT light does

WARNING: CAUTION:

not light after 10 seconds, return to step 3. Continue to

hold the control knob in for about one minute after the

pilot is lit. Release knob and it will pop back out. Pilot

should remain lit. If it goes out, repeat steps 3 through 6.

DO NOT CONNECT 110 VAC TO THE CONTROL VALVE.

Improper installation, adjustment, al- teration, service or maintenance can cause injury or property damage. Re- fer to the owner’s information manual provided with this appliance.

This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate combustion and ventilation air.

If not installed, operated, and main- tained in accordance with the man- ufacturer’s instructions, this product could expose you to substances in fuel or fuel combustion which are known to the State of California to cause can- cer, birth defects, or other reproduc- tive harm.

Keep burner and control compartment clean. See installation and operating instructions accompanying appliance.

Hot while in operation. Do not touch. Keep children, clothing, furniture, gaso- line and other liquids having flammable vapors away.

Do not operate the appliance with panel(s) removed, cracked or broken. Replacement of the panel(s) should be done by a licensed or qualified service person.

NOT FOR USE

WITH SOLID FUEL

For use with natural gas and propane. A conversion kit, as supplied by the manufacturer, shall be used to convert this appliance to the alternate fuel.

Also Certified for Installation in a Bedroom or a Bedsitting Room.

For assistance or additional informa- tion, consult a qualified installer, ser- vice agency or the gas supplier.

If knob does not pop up when released, stop and im-

 

mediately call your service technician or gas supplier.

If the pilot will not stay lit after several tries, turn

 

the gas control knob to “OFF” and call your service

 

technician or gas supplier.

7.

Turn gas control knob counterclockwise to

“ON”.

8.To light Burner, flip the on/off switch to the “ON” position, and close access grille.

9.Turn on all electric power to the appliance.

TO TURN OFF GAS TO APPLIANCE

1. Turn off all electric power to the appliance if service is to be performed.

2.

Open control access panel.

3.

Move switch to “OFF” position.

4.

Push in gas control knob slightly and turn clock-

 

wise

to OFF”. Do not force.

For additional information on operating your

Hearth & Home Technologies fireplace, please refer to www.fireplaces.com.

5.

Close control access panel.

 

464-903G

Quadra-Fire • QVI30S, QVI35S • 340-901 Rev. i • 6/09

29

 

Image 29
Contents HOT Surfaces ModelsWhat to do if you smell gas Xxxxxxxx Homeowner Reference InformationTable of Contents Listing and Code Approvals Getting Started Design and Installation ConsiderationsTools and Supplies Needed Inspect Appliance and ComponentsMinimum Appliance Size Location Fireplace Size RequirementsMinimum Fireplace Opening Clearances to Mantels or other Combustibles above Appliance ClearancesVent Termination Minimum Clearances Termination LocationsVent Table Key Vent Information and DiagramsHorizontal Venting Measuring StandardsInstallation Preparation Venting Components Installing Vent Pipe and ApplianceConnecting Vent Pipe Placing, Securing and Leveling the Appliance Factory Built Wood Burning Installing Adaptor and Termination CapDamper Flashing Kit Optional Class a PipeGas Pressures Gas InformationFuel Conversions Gas Connection Check for GAS Leaks High Altitude InstallationsON/OFF Switch Wiring the ApplianceElectrical Information Appliance RequirementsOptional Accessories Junction Box InstallationFAN Junction BOX Mantel Projections FinishingClean the Appliance Appliance SetupAccessories Ember PlacementModels Supreme-XT, Grand-XT Refractory PlacementQVI30, QVI35, ADI60 Refractory from the packagingPositioning the Logs Log Set Assembly LOGS-QVI30Quadra-Fire QVI30S, QVI35S 340-901 Rev. i 6/09 Quadra-Fire QVI30S, QVI35S 340-901 Rev. i 6/09 Log Set Assembly LOGS-QVI35 Quadra-Fire QVI30S, QVI35S 340-901 Rev. i 6/09 Air Shutter Setting Glass AssemblyRemoving Glass Assembly Replacing Glass AssemblyBefore operating this appliance have a qualified technician Operating InstructionsBefore Lighting Appliance What to do if YOU Smell GAS Lighting ApplianceStanding Pilot Ignition After Appliance is Lit Initial Break-in ProcedureCheck Pilot Flame Appearance Issue Solutions Frequently Asked QuestionsStanding Pilot Ignition System TroubleshootingSymptom Possible Causes Corrective Action Symptom Possible Cause Corrective Action TroubleshootingMaintaining and Servicing Appliance Maintenance TasksDoors, Surrounds Inspect Maintenance TasksReference Materials Appliance Dimension DiagramDirect Vent Flex Liner Kits Vent Kits ComponentsPart number list on following Service PartsAt Depot Service PartsQVI35S Log Set AssemblyNGKS-QVI35 QVI30S, QVI35S Standing Pilot Valve AssemblyLimited Lifetime Warranty Quadra-Fire QVI30S, QVI35S 340-901 Rev. i 6/09 Contact Information

QVI35S, QVI30S specifications

The Quadra-Fire QVI35S and QVI30S are two impressive gas stoves that exemplify modern heating technology while prioritizing efficiency and aesthetics. As part of Quadra-Fire's renowned lineup, both models provide homeowners with outstanding performance and quality design.

One of the primary features of the QVI35S and QVI30S is their high efficiency rating. These stoves boast an impressive efficiency of up to 85%, which means that the majority of the fuel used is converted into heat for your home. This not only translates to lower energy bills but also less frequent fuel replenishment, making them cost-effective and environmentally friendly choices for heating.

Both models feature Quadra-Fire’s innovative heat management system, which ensures even heat distribution throughout the room. This system allows for efficient use of the fire's energy, maximizing warmth and minimizing heat loss. The QVI35S is particularly suited for larger spaces, capable of heating areas up to 1,800 square feet, while the QVI30S is ideal for medium-sized rooms, heating areas of up to 1,500 square feet.

The aesthetics of the QVI35S and QVI30S cannot be overlooked. Both models come with a variety of customizable options including black, pewter, or gold finishes, allowing homeowners to match their stove with their interior decor. The large viewing window enhances the visual appeal, offering a stunning display of the flame and creating a cozy ambiance in any room.

In terms of performance, both models feature the advanced Direct Vent technology. This system ensures that combustion air is drawn from outside the home, which helps maintain excellent indoor air quality. Additionally, the balanced flue design directs exhaust gases safely outside, minimizing emissions.

The stoves also incorporate an easy-to-use control system. Users can quickly adjust the flame height and heat output, allowing for precise temperature control. This feature, combined with the built-in fan option, ensures that heat is circulated effectively, providing optimal comfort.

Easy maintenance is another advantage of the QVI35S and QVI30S. They are designed for simple cleaning, with removable components and an accessible ash pan. This user-friendly design ensures that maintaining your stove is hassle-free.

In conclusion, the Quadra-Fire QVI35S and QVI30S deliver a blend of efficiency, aesthetic appeal, and advanced technology. They provide reliable heating solutions, customizable designs, and user-friendly features, making them excellent additions to any home looking to stay warm and stylish.