Quadra-Fire QVI35S, QVI30S owner manual Maintaining and Servicing Appliance, Maintenance Tasks

Page 34

14 Maintaining and Servicing Appliance

A. Maintenance Tasks

Although the frequency of appliance servicing and maintenance will depend on use and the type of installation, a qualified service technician should perform an appliance checkup at the beginning of each heating season.

WARNING

Risk of injury or property damage.

Before servicing:

Turn off gas.

Turn off electricity to appliance.

Disable remote control, if one is present.

Ensure appliance is completely cooled.

After servicing:

Replace any screen or barrier that was removed.

Reseal and reinstall any venting removed for servicing.

WARNING

Annual inspection by qualified technician recommended.

Check:

Condition of doors, surrounds and fronts.

Condition of glass, glass assembly and glass seal.

Obstructions of combustion and ventilation air.

Condition of logs.

Condition of firebox.

Burner ignition and operation.

Burner air shutter adjustment

Gas connections and fittings.

Obstructions of termination cap.

Clean:

• Glass

Air passageways, grilles, control compartment

Burner, burner ports

Risk of:

Fire

Delayed ignition or explosion

Exposure to combustion fumes

Odors

CAUTION

Handle glass assembly with care.

NOTE: Clean glass after initial 3-4 hours operation.

Longer operation without cleaning glass may cause a permanent white film on glass.

When cleaning glass door:

Avoid striking, scratching or slamming glass.

Do NOT use abrasive cleaners.

Use a hard water deposit glass cleaner on white film.

Do NOT clean glass when hot.

Turn off appliance after 3-4 hours of operation and

ALLOW TO COOL.

Remove and clean glass assembly.

Replace glass assembly and operate appliance for additional 12 hours.

Refer to maintenance instructions.

WARNING

Inspect external vent cap regularly.

Ensure no debris blocks cap.

Combustible materials blocking cap may ignite.

Restricted air flow affects burner operation.

34

Quadra-Fire • QVI30S, QVI35S • 340-901 Rev. i • 6/09

 

Image 34
Contents What to do if you smell gas ModelsHOT Surfaces Homeowner Reference Information XxxxxxxxTable of Contents Listing and Code Approvals Tools and Supplies Needed Design and Installation ConsiderationsGetting Started Inspect Appliance and ComponentsMinimum Fireplace Opening Fireplace Size RequirementsMinimum Appliance Size Location Clearances Clearances to Mantels or other Combustibles above ApplianceTermination Locations Vent Termination Minimum ClearancesHorizontal Venting Vent Information and DiagramsVent Table Key Measuring StandardsInstallation Preparation Connecting Vent Pipe Installing Vent Pipe and ApplianceVenting Components Placing, Securing and Leveling the Appliance Damper Flashing Kit Optional Installing Adaptor and Termination CapFactory Built Wood Burning Class a PipeFuel Conversions Gas Connection Gas InformationGas Pressures High Altitude Installations Check for GAS LeaksElectrical Information Wiring the ApplianceON/OFF Switch Appliance RequirementsJunction Box Installation Optional AccessoriesFAN Junction BOX Finishing Mantel ProjectionsAccessories Appliance SetupClean the Appliance Ember PlacementQVI30, QVI35, ADI60 Refractory PlacementModels Supreme-XT, Grand-XT Refractory from the packagingLog Set Assembly LOGS-QVI30 Positioning the LogsQuadra-Fire QVI30S, QVI35S 340-901 Rev. i 6/09 Quadra-Fire QVI30S, QVI35S 340-901 Rev. i 6/09 Log Set Assembly LOGS-QVI35 Quadra-Fire QVI30S, QVI35S 340-901 Rev. i 6/09 Removing Glass Assembly Glass AssemblyAir Shutter Setting Replacing Glass AssemblyBefore Lighting Appliance Operating InstructionsBefore operating this appliance have a qualified technician Standing Pilot Ignition Lighting ApplianceWhat to do if YOU Smell GAS Check Pilot Flame Appearance Initial Break-in ProcedureAfter Appliance is Lit Frequently Asked Questions Issue SolutionsSymptom Possible Causes Corrective Action TroubleshootingStanding Pilot Ignition System Troubleshooting Symptom Possible Cause Corrective ActionMaintenance Tasks Maintaining and Servicing ApplianceInspect Maintenance Tasks Doors, SurroundsAppliance Dimension Diagram Reference MaterialsVent Kits Components Direct Vent Flex Liner KitsService Parts Part number list on followingService Parts At DepotLog Set Assembly QVI35SNGKS-QVI35 Standing Pilot Valve Assembly QVI30S, QVI35SLimited Lifetime Warranty Quadra-Fire QVI30S, QVI35S 340-901 Rev. i 6/09 Contact Information

QVI35S, QVI30S specifications

The Quadra-Fire QVI35S and QVI30S are two impressive gas stoves that exemplify modern heating technology while prioritizing efficiency and aesthetics. As part of Quadra-Fire's renowned lineup, both models provide homeowners with outstanding performance and quality design.

One of the primary features of the QVI35S and QVI30S is their high efficiency rating. These stoves boast an impressive efficiency of up to 85%, which means that the majority of the fuel used is converted into heat for your home. This not only translates to lower energy bills but also less frequent fuel replenishment, making them cost-effective and environmentally friendly choices for heating.

Both models feature Quadra-Fire’s innovative heat management system, which ensures even heat distribution throughout the room. This system allows for efficient use of the fire's energy, maximizing warmth and minimizing heat loss. The QVI35S is particularly suited for larger spaces, capable of heating areas up to 1,800 square feet, while the QVI30S is ideal for medium-sized rooms, heating areas of up to 1,500 square feet.

The aesthetics of the QVI35S and QVI30S cannot be overlooked. Both models come with a variety of customizable options including black, pewter, or gold finishes, allowing homeowners to match their stove with their interior decor. The large viewing window enhances the visual appeal, offering a stunning display of the flame and creating a cozy ambiance in any room.

In terms of performance, both models feature the advanced Direct Vent technology. This system ensures that combustion air is drawn from outside the home, which helps maintain excellent indoor air quality. Additionally, the balanced flue design directs exhaust gases safely outside, minimizing emissions.

The stoves also incorporate an easy-to-use control system. Users can quickly adjust the flame height and heat output, allowing for precise temperature control. This feature, combined with the built-in fan option, ensures that heat is circulated effectively, providing optimal comfort.

Easy maintenance is another advantage of the QVI35S and QVI30S. They are designed for simple cleaning, with removable components and an accessible ash pan. This user-friendly design ensures that maintaining your stove is hassle-free.

In conclusion, the Quadra-Fire QVI35S and QVI30S deliver a blend of efficiency, aesthetic appeal, and advanced technology. They provide reliable heating solutions, customizable designs, and user-friendly features, making them excellent additions to any home looking to stay warm and stylish.