A. Design and Installation Considerations

Quadra-Fire direct vent gas appliances are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside. No additional outside air source is required.

CAUTION

Check building codes prior to installation.

Installation MUST comply with local, regional, state and national codes and regulations.

Consult insurance carrier, local building, fire officials or authorities having jurisdiction about restrictions, installation inspection, and permits.

Quadra-Fire gas inserts are designed for recessed installa- tions into solid fuel masonry or factory built non-combustible fireplaces that have been installed in accordance with the National, Provincial, State and local building codes.

Prior to installing the gas insert:

Have the chimney and adjacent structure inspected and cleaned by qualified professionals. Hearth & Home Technologies recommends that NFI or CSIA certified professionals, or technicians under the direction of certi- fied professionals, conduct a minimum of a NFPA 211 Level 2 inspection of the chimney.

Replace component parts of the chimney and fireplace as specified by the professionals.

Ensure all joints are properly engaged and the chimney is properly secured.

When planning an appliance installation, it’s necessary to determine the following information before installing:

Minimum fireplace size. See Section 3.A.

Gas supply piping.

Electrical wiring.

Finishing details.

Existing mantel, mantel legs and wall projection loca- tions. See Section 3.C.

Whether optional accessories—devices such as a fan, wall switch, or remote control—are desired.

B. Tools and Supplies Needed

Before beginning the installation be sure that the following tools and building supplies are available.

Pliers

Hi temp caulking material

Hammer

Flat blade screwdriver

Voltmeter

Framing square

Gloves

Variable speed drill

1/4 Hex drive

Safety glasses

Manometer

Phillips screwdriver

Tape measure

Non-corrosive leak check solution

1/2 - 3/4 inch length, #6 or #8 Self-drilling screws

C. Inspect Appliance and Components

WARNING

Inspect appliance and components for damage. Damaged parts may impair safe operation.

• Do NOT install damaged components.

Do NOT install incomplete components.

Do NOT install substitute components. Report damaged parts to dealer.

Carefully remove the appliance and components from the packaging.

The vent system components, surrounds and fronts are shipped in separate packages.

The fiber logs may be packaged separately and must be field installed.

Report to your dealer any parts damaged in shipment, particularly the condition of the glass.

Read all of the instructions before starting the insta- llation. Follow these instructions carefully during the installation to ensure maximum safety and benefit.

WARNING

Hearth & Home Technologies disclaims any responsibility for, and the warranty will be voided by, the following actions:

Installation and use of any damaged appliance or vent system component.

Modification of the appliance or vent system.

Installation other than as instructed by Hearth & Home Technologies.

Improper positioning of the gas logs or the glass door.

Installation and/or use of any component part not approved by Hearth & Home Technologies.

Any such action may cause a fire hazard.

WARNING

Keep appliance dry.

• Mold or rust may cause odors.

• Water may damage controls.

Quadra-Fire • QVI30S, QVI35S • 340-901 Rev. i • 6/09

5

 

Image 5
Contents HOT Surfaces ModelsWhat to do if you smell gas Xxxxxxxx Homeowner Reference InformationTable of Contents Listing and Code Approvals Getting Started Design and Installation ConsiderationsTools and Supplies Needed Inspect Appliance and ComponentsMinimum Appliance Size Location Fireplace Size RequirementsMinimum Fireplace Opening Clearances to Mantels or other Combustibles above Appliance ClearancesVent Termination Minimum Clearances Termination LocationsVent Table Key Vent Information and DiagramsHorizontal Venting Measuring StandardsInstallation Preparation Venting Components Installing Vent Pipe and ApplianceConnecting Vent Pipe Placing, Securing and Leveling the Appliance Factory Built Wood Burning Installing Adaptor and Termination CapDamper Flashing Kit Optional Class a PipeGas Pressures Gas InformationFuel Conversions Gas Connection Check for GAS Leaks High Altitude InstallationsON/OFF Switch Wiring the ApplianceElectrical Information Appliance RequirementsOptional Accessories Junction Box InstallationFAN Junction BOX Mantel Projections FinishingClean the Appliance Appliance SetupAccessories Ember PlacementModels Supreme-XT, Grand-XT Refractory PlacementQVI30, QVI35, ADI60 Refractory from the packagingPositioning the Logs Log Set Assembly LOGS-QVI30Quadra-Fire QVI30S, QVI35S 340-901 Rev. i 6/09 Quadra-Fire QVI30S, QVI35S 340-901 Rev. i 6/09 Log Set Assembly LOGS-QVI35 Quadra-Fire QVI30S, QVI35S 340-901 Rev. i 6/09 Air Shutter Setting Glass AssemblyRemoving Glass Assembly Replacing Glass AssemblyBefore operating this appliance have a qualified technician Operating InstructionsBefore Lighting Appliance What to do if YOU Smell GAS Lighting ApplianceStanding Pilot Ignition After Appliance is Lit Initial Break-in ProcedureCheck Pilot Flame Appearance Issue Solutions Frequently Asked QuestionsStanding Pilot Ignition System TroubleshootingSymptom Possible Causes Corrective Action Symptom Possible Cause Corrective Action TroubleshootingMaintaining and Servicing Appliance Maintenance TasksDoors, Surrounds Inspect Maintenance TasksReference Materials Appliance Dimension DiagramDirect Vent Flex Liner Kits Vent Kits ComponentsPart number list on following Service PartsAt Depot Service PartsQVI35S Log Set AssemblyNGKS-QVI35 QVI30S, QVI35S Standing Pilot Valve AssemblyLimited Lifetime Warranty Quadra-Fire QVI30S, QVI35S 340-901 Rev. i 6/09 Contact Information

QVI35S, QVI30S specifications

The Quadra-Fire QVI35S and QVI30S are two impressive gas stoves that exemplify modern heating technology while prioritizing efficiency and aesthetics. As part of Quadra-Fire's renowned lineup, both models provide homeowners with outstanding performance and quality design.

One of the primary features of the QVI35S and QVI30S is their high efficiency rating. These stoves boast an impressive efficiency of up to 85%, which means that the majority of the fuel used is converted into heat for your home. This not only translates to lower energy bills but also less frequent fuel replenishment, making them cost-effective and environmentally friendly choices for heating.

Both models feature Quadra-Fire’s innovative heat management system, which ensures even heat distribution throughout the room. This system allows for efficient use of the fire's energy, maximizing warmth and minimizing heat loss. The QVI35S is particularly suited for larger spaces, capable of heating areas up to 1,800 square feet, while the QVI30S is ideal for medium-sized rooms, heating areas of up to 1,500 square feet.

The aesthetics of the QVI35S and QVI30S cannot be overlooked. Both models come with a variety of customizable options including black, pewter, or gold finishes, allowing homeowners to match their stove with their interior decor. The large viewing window enhances the visual appeal, offering a stunning display of the flame and creating a cozy ambiance in any room.

In terms of performance, both models feature the advanced Direct Vent technology. This system ensures that combustion air is drawn from outside the home, which helps maintain excellent indoor air quality. Additionally, the balanced flue design directs exhaust gases safely outside, minimizing emissions.

The stoves also incorporate an easy-to-use control system. Users can quickly adjust the flame height and heat output, allowing for precise temperature control. This feature, combined with the built-in fan option, ensures that heat is circulated effectively, providing optimal comfort.

Easy maintenance is another advantage of the QVI35S and QVI30S. They are designed for simple cleaning, with removable components and an accessible ash pan. This user-friendly design ensures that maintaining your stove is hassle-free.

In conclusion, the Quadra-Fire QVI35S and QVI30S deliver a blend of efficiency, aesthetic appeal, and advanced technology. They provide reliable heating solutions, customizable designs, and user-friendly features, making them excellent additions to any home looking to stay warm and stylish.