Napco Security Technologies WI1501A Wiring Connections, Transformer, SIREN/BELL Power

Page 11

WI1501A 9/06

Page 11 

WIRING CONNECTIONS

BATTERY

7

The RED (+) and BLACK (-) flying leads must be connected to a 12VDC 4-7 AH Rechargeable Battery, to serve as backup power in the event of AC Power Failure. NOTE: To calculate the available standby time refer to the Standby- Battery Calculation Worksheet at the back of this manual.

Wiring

TRANSFORMER

(The following applies to installations in the United States of America): Connect a 16.5 VAC Transformer to Terminals 1 and 2, using a wire of #18 AWG. or larger at a distance of 15 ft. or less from the control panel. NOTE: Do not connect to a switched outlet.

SIREN/BELL POWER

Connect the alarm sounding devices (self-contained sirens,

 

speakers or a mechanical bell) to Terminals 3 and 4. Any self-

 

contained siren requiring a 12 VDC input can be connected.

 

When connecting a mechanical bell, it must be supervised

 

using a 2.2k Ohm resistor. To connect 8 Ohm Speakers use a

 

Siren Driver with the proper polarity observed. NOTE: Refer to

 

the F-64 Panel Wiring Diagram for alarm current specification.

 

Note: In NFPA Household Fire Installations, only a single si-

 

ren or bell can be used on this bell circuit.

AUXILIARY POWER

Connect the auxiliary devices (motion detectors, glass breaks, etc.) to Terminals 5 and 6. Auxiliary Power provides 11.7-12.5 VDC nominal output which is used for powering auxiliary devices. NOTE: To calculate the available standby time refer to the Standby-Battery Calculation Worksheet at the back of this manual.

Connections: Battery, Transformer, Siren Power, Aux. Power & PGM

PGM OUTPUTS (PGM1 & PGM2)

PGM1 and PGM2 are negative switched programmable outputs that can be activated depending on the programming options selected (see F-64 Panel Programming Instructions). Connect the device controlled by the programmable output between terminal 5

(+)and the PGM output (-), either terminal 7 or

8. As an example, the connection to the RB1000 Relay Module is shown.

Outputs

L NAPCO Security Systems

Freedom F-64 Installation Instructions

 

Image 11
Contents Napco Freedom FImportant Notice Table of Contents Page WI1501A 9/06 IntroductionWI1501A 9/06 5  SpecificationsSystem Components Ordering InformationWheelock AH-12WP Summary of UL RequirementsWI1501A 9/06 7  Control Panel InstallationWI1501A 9/06 9  WiringRestore the wireless point close the loop Testing the SystemTransformer Wiring ConnectionsSIREN/BELL Power Auxiliary PowerEarth Ground Remote BUSEZ Zone Doublingtm Configuration Basic Zone ConfigurationWire Smoke Detector Wiring Wire Smoke DetectorsWI1501A 9/06 15  Telephone LinesKeypad / Touchpad Messages Keypad / Touchpad MessagesWI1501A 9/06 17  AC Failure AC-Fail Report DelayGlossary Areas Zone Area 1-Zone Area 4 Priority Area Arming Alarm OutputsAmbush Touchpad Ambush Ambush Codes Enable Global Ambush WI1501A 9/06 19  Auto Status DisableBackup Report on Telco 1/Telco BatteryCold Start Chime ZoneChirp Output on Keyfob Arm/Disarm Date/Time WI1501A 9/06 21 Data Format Digital Dialer Test Dial-Tone Detection Disable Auto Dial-Tone DetectionDigital Dialer Report Enter/Exit Test Mode Dealer Security CodeWI1501A 9/06 23  Easy Exit Enable CP-01 LimitsEnable TCP/IP Communications WI1501A 9/06 25  Keyfob Control of Relay Groups 1 Keyfob Arm/Disarm chirp of Alarm OutputFire Verification Not for use in California GEM-PrintWI1501A 9/06 27  Page 28WI1501A 9/06 WI1501A 9/06 29  Page 30WI1501A 9/06 Subscriber ID Numbers Account Number Sound Alarm On Exit ErrorSuppress Bypass Icon When Armed WI1501A 9/06 31 Timeout Wire, 4-Wire Smoke Detectors See Smoke Detectors Hour ZoneTest Timer Cancel Next Test Timer Report on Any Report WI1501A 9/06 33  Zone Area 1-4 See Areas Trouble on Open Trouble on Short Not for UL installationsTrouble Fire Trouble Zone DirectoryZone Status WI1501A 9/06 35 Standby Time in Hours Box Standby Time1 STANDBY-BATTERY Calculation WorksheetAlarm current drawn in alarm WI1501A 9/06 37  Wiring LegendLocation Programming AddressWI1501A 9/06 39  Out of Box Panel Operation Factory Default DescriptionOut of Box Panel Operation Prior to CP-01 Changes WI1501A 9/06 41 FCC Statement WI1501A 9/06 43  Freedom F-64 Wiring DiagramNapco Limited Warranty

WI1501A specifications

Napco Security Technologies has long been a trusted name in the security industry, and their WI1501A model is no exception. This advanced wireless intrusion detection and communication solution is engineered to offer exceptional performance, reliability, and versatility, making it a popular choice for both residential and commercial applications.

One of the standout features of the Napco WI1501A is its innovative wireless technology. The unit operates on a robust 433 MHz frequency, ensuring a stable connection with minimal interference from other devices. This frequency allows the WI1501A to cover a significant range, providing flexibility in installation without the constraint of wired connections. Its wireless capability simplifies the installation process, allowing for quick setup and repositioning if necessary.

The WI1501A is equipped with advanced motion detection technology. It utilizes passive infrared (PIR) sensors to accurately detect movement within its monitored area. These sensors are designed to minimize false alarms, ensuring that users are only alerted when genuine activity is identified. This feature is particularly valuable in environments with pets or fluctuating temperature conditions, as the sensors can distinguish between legitimate threats and non-threatening movements.

Another essential aspect of the WI1501A is its integration capabilities. It seamlessly integrates with Napco's central monitoring systems and can be customized to work with various other security components. This interoperability allows users to expand their security systems without worrying about compatibility issues.

Durability is also a key characteristic of the Napco WI1501A. Designed to withstand different environmental conditions, the unit is suitable for both indoor and outdoor installations. Its robust housing protects it from dust and moisture, ensuring long-lasting performance even in challenging settings.

The WI1501A boasts a user-friendly interface and is compatible with smartphone applications, enabling users to monitor their security systems remotely. Customizable settings allow users to tailor the system to their specific needs, whether they require immediate alerts or scheduled monitoring.

In conclusion, Napco Security Technologies' WI1501A is a versatile, reliable, and technologically advanced security solution. With its wireless technology, advanced motion detection, integration capabilities, durability, and user-friendly features, it represents a compelling option for anyone looking to enhance their security measures.