Zone Number on Pulse Alarm See Data Formats: Two-Digit Format

Zone Response Time (750mS required for UL installations)

Loop response is the amount of time in milliseconds (mS) that a normally-closed circuit must remain open, or a normally-open circuit must remain closed, to trigger an alarm. The slower the loop response, the more immune the system will be to intermittents ("swingers"). Loop response times for Zones 1 through 8 are programmed into the control panel; Zones 9-16 with "Zone Doubling" enabled have loop responses the same as their respective 1-8 zones; those for Zones 9 through 64 loop responses are selected in the respective Touchpad Configuration Mode or expansion zone module jumper. The panel Zone Response time can be adjusted to a new global value. Address 2062 accepts three decimal digits which are multiplied by 10 milliseconds to get a new value that replaces the default value of 750ms. If the location is set to 000 the system will default to 750ms internally. The maximum value is 255. If a value above 255 is entered the system will display 000 to request a re-entry. Note: Only the panel zones’ integration times are pro- grammable. EZM’s will continue to use either 50 or 750 ms as selected by jumpers on the EZM. In addition, zone responses are en- abled only when armed.

Selectable loop-response times for Zones 1–8 are:

750mS (.75 sec.): The slowest loop-response time, recommended for use with magnetic contacts, window foil, etc. Unless programmed otherwise, loop-response time will be 750mS for all zones.

50mS (.05 sec.): Used for momentary Panic Buttons and area-protection devices, such as photoelectric eyes, passive infrared sensors, floor mats, etc.

Zone Status

In high security installations where Disable Auto Status has been programmed, enter the User code at the keypad and press R until "DISPLAY ZONE STATUS Y/N" is displayed. Press NEXT/YES and then NEXT/PRIOR to scroll through any faulted zones.

Zone Type See Central Station Receiver Data Formats: Modem Formats

Glossary

L NAPCO Security Systems

Freedom F-64 Installation Instructions

 

Image 35
Contents Napco Freedom FImportant Notice Table of Contents Page WI1501A 9/06 IntroductionWI1501A 9/06 5  SpecificationsSystem Components Ordering InformationWheelock AH-12WP Summary of UL RequirementsWI1501A 9/06 7  Control Panel InstallationWI1501A 9/06 9  WiringRestore the wireless point close the loop Testing the SystemTransformer Wiring ConnectionsSIREN/BELL Power Auxiliary PowerEarth Ground Remote BUSEZ Zone Doublingtm Configuration Basic Zone ConfigurationWire Smoke Detector Wiring Wire Smoke DetectorsWI1501A 9/06 15  Telephone LinesKeypad / Touchpad Messages Keypad / Touchpad MessagesWI1501A 9/06 17  AC Failure AC-Fail Report DelayGlossary Areas Zone Area 1-Zone Area 4 Priority Area Arming Alarm OutputsAmbush Touchpad Ambush Ambush Codes Enable Global Ambush WI1501A 9/06 19  Auto Status DisableBackup Report on Telco 1/Telco BatteryCold Start Chime ZoneChirp Output on Keyfob Arm/Disarm Date/Time WI1501A 9/06 21 Data Format Digital Dialer Test Dial-Tone Detection Disable Auto Dial-Tone DetectionDigital Dialer Report Enter/Exit Test Mode Dealer Security CodeWI1501A 9/06 23  Easy Exit Enable CP-01 LimitsEnable TCP/IP Communications WI1501A 9/06 25  Keyfob Control of Relay Groups 1 Keyfob Arm/Disarm chirp of Alarm OutputFire Verification Not for use in California GEM-PrintWI1501A 9/06 27  Page 28WI1501A 9/06 WI1501A 9/06 29  Page 30WI1501A 9/06 Subscriber ID Numbers Account Number Sound Alarm On Exit ErrorSuppress Bypass Icon When Armed WI1501A 9/06 31 Timeout Wire, 4-Wire Smoke Detectors See Smoke Detectors Hour ZoneTest Timer Cancel Next Test Timer Report on Any Report WI1501A 9/06 33  Zone Area 1-4 See Areas Trouble on Open Trouble on Short Not for UL installationsTrouble Fire Trouble Zone DirectoryZone Status WI1501A 9/06 35 Standby Time in Hours Box Standby Time1 STANDBY-BATTERY Calculation WorksheetAlarm current drawn in alarm WI1501A 9/06 37  Wiring LegendLocation Programming AddressWI1501A 9/06 39  Out of Box Panel Operation Factory Default DescriptionOut of Box Panel Operation Prior to CP-01 Changes WI1501A 9/06 41 FCC Statement WI1501A 9/06 43  Freedom F-64 Wiring DiagramNapco Limited Warranty

WI1501A specifications

Napco Security Technologies has long been a trusted name in the security industry, and their WI1501A model is no exception. This advanced wireless intrusion detection and communication solution is engineered to offer exceptional performance, reliability, and versatility, making it a popular choice for both residential and commercial applications.

One of the standout features of the Napco WI1501A is its innovative wireless technology. The unit operates on a robust 433 MHz frequency, ensuring a stable connection with minimal interference from other devices. This frequency allows the WI1501A to cover a significant range, providing flexibility in installation without the constraint of wired connections. Its wireless capability simplifies the installation process, allowing for quick setup and repositioning if necessary.

The WI1501A is equipped with advanced motion detection technology. It utilizes passive infrared (PIR) sensors to accurately detect movement within its monitored area. These sensors are designed to minimize false alarms, ensuring that users are only alerted when genuine activity is identified. This feature is particularly valuable in environments with pets or fluctuating temperature conditions, as the sensors can distinguish between legitimate threats and non-threatening movements.

Another essential aspect of the WI1501A is its integration capabilities. It seamlessly integrates with Napco's central monitoring systems and can be customized to work with various other security components. This interoperability allows users to expand their security systems without worrying about compatibility issues.

Durability is also a key characteristic of the Napco WI1501A. Designed to withstand different environmental conditions, the unit is suitable for both indoor and outdoor installations. Its robust housing protects it from dust and moisture, ensuring long-lasting performance even in challenging settings.

The WI1501A boasts a user-friendly interface and is compatible with smartphone applications, enabling users to monitor their security systems remotely. Customizable settings allow users to tailor the system to their specific needs, whether they require immediate alerts or scheduled monitoring.

In conclusion, Napco Security Technologies' WI1501A is a versatile, reliable, and technologically advanced security solution. With its wireless technology, advanced motion detection, integration capabilities, durability, and user-friendly features, it represents a compelling option for anyone looking to enhance their security measures.