Napco Security Technologies WI1501A installation instructions Keypad / Touchpad Messages

Page 16

Page 16

WI1501A 9/06

KEYPAD / TOUCHPAD MESSAGES

The F-64PROG Programmer and Touchpads can display the below messages. Note: See page 6 for a listing of the keypad / Touchpad specific User Guides available. These User Guides contain more details regarding the various messages.

Keypad / Touchpad Messages

SYSTEM READY - All zones operating; system can be armed. 1 through 4 = Area.

ARMING YYY/XXX SECONDS - Exit delay in progress. XXX = exit time remaining in 10-second decrements; YYY = AWAY or STAY. Arming then becomes ARMED.

DISARM NOW/XXX SECONDS - Entry delay in progress. XXX = entry time remaining in 10-second decrements.

SYSTEM ARMED - Panel armed.

ZONE FAULTED - One or more zones not secured. Display status for zone description(s).

CAN'T ARM SYSTEM/ZONE FAULTED - Arming attempted with Priority Zone in trouble. Secure zone to arm.

DAY ZONE TROUBLE - Trouble condition on Day Zone, followed by one or more zone descriptions.

INVALID ENTRY/TRY AGAIN - Wrong code/time/area number entered.

CAN'T ARM SYSTEM/PRESS RESET KEY - Arming attempted with System Trouble present. Press RESET and then arm the system.

ALARM - Alarm condition, followed by one or more zone descriptions.

FIRE ALARM - Alarm condition on a Fire Zone. Enter your code then press the Ubutton to silence the sounder. Correct the

cause of the alarm, then press RESET again. Fire alarm condition, followed by one or more zone descriptions.

SYSTEM TROUBLE - A System Trouble display will be followed by one or more of the following error codes:

AC POWER FAIL/E01-00 SERVICE. Power failure. Check power transformer. Check for blown fuse or circuit breaker; general power outage.

LOW BATTERY/E02-00 SERVICE. Battery below 11 volts. If not recharged within 24 hours, replace it.

COMM FAIL/E03-00 SERVICE. Unsuccessful communication to central station. Note: Will also display if panel improperly programmed to report; i.e., Report Alarm, Report Codes, Subscriber ID Numbers, etc. must be programmed.

WIRELESS TROUBLE/04-NN SERVICE. Wireless transmitter supervisory failure. NN = transmitter number.

WIRELESS LOWBATT/E05-NN SERVICE. RF transmitter low battery. NN = transmitter number.

SYSTEM TROUBLE/E06-NN SERVICE. RF receiver response trouble. NN = receiver number.

SYSTEM TROUBLE/E07-00 SERVICE. Download failure.

SYSTEM TROUBLE/E08-00 SERVICE. Telephone line failure (system trouble displays after a fixed 60 second delay).

SYSTEM TROUBLE/E09-00 SERVICE, NO PANEL PROGRAM. System cold start not programmed after address 2286.

SYSTEM TROUBLE/E10-NN SERVICE. Keypad/Touchpad response failure. NN = Keypad/Touchpad number.

SYSTEM TROUBLE/E11-NN SERVICE. Keypad/Touchpad tamper cover removed. NN = Keypad/Touchpad number.

SYSTEM TROUBLE/E12-NN SERVICE. Expansion zone module failure. NN = module number.

SYSTEM TROUBLE/E13-NN SERVICE. EZM module cover removed. NN = module number.

SYSTEM TROUBLE/E14-NN SERVICE. Relay board response failure. NN = relay board number.

SYSTEM TROUBLE/E15-NN SERVICE. Wireless transmitter tamper cover removed. NN = transmitter number.

SYSTEM TROUBLE/E16-NN SERVICE. Receiver jammed. NN = receiver number.

SYSTEM TROUBLE/E17-NN SERVICE. Receiver cover removed. NN = receiver number.

SYSTEM TROUBLE/E18-NN SERVICE. Keyfob RF transmitter low battery. NN = keyfob transmitter number.

SYSTEM TROUBLE/E19-00 SERVICE. Internal user memory error. Select RESET SYSTEM TBL. Press the YES button.

SYSTEM TROUBLE/E20-00 SERVICE. Internal dealer memory error.

SYSTEM TROUBLE/E22-NN SERVICE. No trip detected on PIR Supervision Zone within programmed Sensor-Watch time.

NN= Zone number. To reset, press NEXT/YES button at “RESET SENSOR MSG” function display.

SYSTEM TROUBLE/E27-00 SERVICE. Printer Failure. Call

installing company for service.

SYSTEM TROUBLE/E39-00 SERVICE. Receiver capacity error. SYSTEM TROUBLE/E40-00 SERVICE. RF Self-Test failure.

SYSTEM TROUBLE/E41-NN SERVICE. Trouble condition on a Fire Zone. Press RESET to silence the sounder. Correct the trouble, then press RESET again.

SYSTEM TROUBLE/E51-00 SERVICE - Alarm Output

Supervisory.

NNOUT OF SYSTEM - Keypad/Touchpad inoperative. NN = Keypad/Touchpad number.

FAULT FIND/RF SIGNAL POWER - Fault-find Mode activated.

Freedom F-64 Installation Instructions

L NAPCO Security Systems

 

Image 16
Contents Freedom F NapcoImportant Notice Table of Contents Introduction Page WI1501A 9/06Specifications WI1501A 9/06 5 Ordering Information System ComponentsWI1501A 9/06 7  Summary of UL RequirementsWheelock AH-12WP Installation Control PanelWiring WI1501A 9/06 9 Testing the System Restore the wireless point close the loopWiring Connections SIREN/BELL PowerAuxiliary Power TransformerRemote BUS Earth GroundBasic Zone Configuration EZ Zone Doublingtm ConfigurationWire Smoke Detectors Wire Smoke Detector WiringTelephone Lines WI1501A 9/06 15 Keypad / Touchpad Messages Keypad / Touchpad MessagesGlossary AC Failure AC-Fail Report DelayWI1501A 9/06 17  Ambush Touchpad Ambush Ambush Codes Enable Global Ambush Alarm OutputsAreas Zone Area 1-Zone Area 4 Priority Area Arming Auto Status Disable Backup Report on Telco 1/TelcoBattery WI1501A 9/06 19 Chirp Output on Keyfob Arm/Disarm Chime ZoneCold Start Data Format WI1501A 9/06 21 Date/Time Dial-Tone Detection Disable Auto Dial-Tone Detection Digital Dialer Report Enter/Exit Test ModeDealer Security Code Digital Dialer TestWI1501A 9/06 23  Enable TCP/IP Communications Enable CP-01 LimitsEasy Exit WI1501A 9/06 25  Keyfob Arm/Disarm chirp of Alarm Output Fire Verification Not for use in CaliforniaGEM-Print Keyfob Control of Relay Groups 1WI1501A 9/06 27  Page 28WI1501A 9/06 WI1501A 9/06 29  Page 30WI1501A 9/06 Sound Alarm On Exit Error Suppress Bypass Icon When ArmedWI1501A 9/06 31  Subscriber ID Numbers Account NumberTest Timer Cancel Next Test Timer Report on Any Report Wire, 4-Wire Smoke Detectors See Smoke Detectors Hour ZoneTimeout WI1501A 9/06 33  Trouble on Open Trouble on Short Not for UL installations Trouble Fire TroubleZone Directory Zone Area 1-4 See AreasWI1501A 9/06 35  Zone StatusAlarm current drawn in alarm STANDBY-BATTERY Calculation WorksheetStandby Time in Hours Box Standby Time1 Wiring Legend WI1501A 9/06 37 Programming Address LocationWI1501A 9/06 39  Factory Default Description Out of Box Panel OperationWI1501A 9/06 41  Out of Box Panel Operation Prior to CP-01 ChangesFCC Statement Freedom F-64 Wiring Diagram WI1501A 9/06 43 Napco Limited Warranty

WI1501A specifications

Napco Security Technologies has long been a trusted name in the security industry, and their WI1501A model is no exception. This advanced wireless intrusion detection and communication solution is engineered to offer exceptional performance, reliability, and versatility, making it a popular choice for both residential and commercial applications.

One of the standout features of the Napco WI1501A is its innovative wireless technology. The unit operates on a robust 433 MHz frequency, ensuring a stable connection with minimal interference from other devices. This frequency allows the WI1501A to cover a significant range, providing flexibility in installation without the constraint of wired connections. Its wireless capability simplifies the installation process, allowing for quick setup and repositioning if necessary.

The WI1501A is equipped with advanced motion detection technology. It utilizes passive infrared (PIR) sensors to accurately detect movement within its monitored area. These sensors are designed to minimize false alarms, ensuring that users are only alerted when genuine activity is identified. This feature is particularly valuable in environments with pets or fluctuating temperature conditions, as the sensors can distinguish between legitimate threats and non-threatening movements.

Another essential aspect of the WI1501A is its integration capabilities. It seamlessly integrates with Napco's central monitoring systems and can be customized to work with various other security components. This interoperability allows users to expand their security systems without worrying about compatibility issues.

Durability is also a key characteristic of the Napco WI1501A. Designed to withstand different environmental conditions, the unit is suitable for both indoor and outdoor installations. Its robust housing protects it from dust and moisture, ensuring long-lasting performance even in challenging settings.

The WI1501A boasts a user-friendly interface and is compatible with smartphone applications, enabling users to monitor their security systems remotely. Customizable settings allow users to tailor the system to their specific needs, whether they require immediate alerts or scheduled monitoring.

In conclusion, Napco Security Technologies' WI1501A is a versatile, reliable, and technologically advanced security solution. With its wireless technology, advanced motion detection, integration capabilities, durability, and user-friendly features, it represents a compelling option for anyone looking to enhance their security measures.