Ambush

Easy Arming (required for Freedom Touchpads)

Touchpad (Police) Panic

Touchpad Auxiliary Panic

Touchpad Fire Panic

Keypad: F-64PROG Programmer and Gemini "K Series" Keypads

Panel automatically detects the Touchpads and keypads installed on the system. The F-64PROG Programmer is used for F-64 control panel programming. Gemini "K Series" keypads may also be installed permanently in certain installations, such as installations that comply with the Security Industry Association False Alarm Reduction Control Panel-01 Standard (SIA FAR CP-01). See page 38 for more information.

Keypad Sounder on Alarm see Touchpad/Keypad Sounder on Alarm

Keypad/Touchpad Panic See Panic Zone

Keypad/Touchpad Tamper See Tamper

Keyswitch Arming; Maintained-Key Input Arming

The area will arm/disarm when the programmed zone is momentarily shorted (momentary keyswitch). To supervise the keyswitch, program the zone for Day Zone on Open. Keyswitch Arming will be reported as User 68. Keyswitch must be provided with EOL resistor. Maintained-key input arming will arm when shorted and disarm when opened.

Line-Reversal Module, M278

The Line-Reversal Module allows the panel to be monitored by a central station through leased lines. On alarm, the module reverses normal line-voltage polarity. For details, refer to the instructions furnished with the module.

Loop Response See Zone Response Time

Low Battery; Wireless Low Battery; Keyfob Low Battery

A low-battery system trouble will annunciate at the Touchpad/keypad when the battery terminal voltage drops below normal. This condition may signal a local sounding device, report to a central station (program Panel Low Bat Report Code), or both. If a battery is installed and low terminal voltage is detected, a restore will not occur until the battery is recharged to its specified level and passes a dynamic test. The dynamic test may be initiated manually by pressing RESET, or it will be initiated automatically, every four hours, by the panel. In wireless installations, when displaying RF transmitter status, a "LoBatt" indication denotes a low-battery condition at the transmitter.

Lug E15 See "E" Lugs

Memory Failure

A User or Dealer Memory error will cause the sounder to pulse, the "SYS/TRBL" reminder to flash, and the display to read "SYSTEM

TROUBLE/E19-00 SERVICE" or "SYSTEM TROUBLE/E20-00 SERVICE". Press RESET to silence the sounder ("SYSTEM READY" will display, along with the "SYS/TRBL" reminder). Activate RESET SYSTEM TROUBLE to manually reset the system trouble. A Memory Failure can be programmed to activate an alarm output and/or report using its associated system Report Code.

Never Arm (Do not use for primary Burglary protection)

A zone programmed as "Never Arm" cannot go into alarm. If tripped, it will display at the Touchpad/keypad when the DISPLAY STATUS function is selected. A chime will sound at the Touchpad/keypad while armed or disarmed if Chime is also programmed for that zone, and enabled at the Touchpad/keypad. This feature is suggested for use as a garage-door or driveway monitor, or similar application.

No EOL Resistor

Program for any zone not wired with a 2200 Ohm end-of-line resistor. This will disable any zone-short indication (if programmed, "Day Zone Short" is disabled). If not programmed, an end-of-line resistor must be installed. Note: This selection is automatically disabled for zones selected as Fire. Note: Do not program for UL installations.

Glossary

L NAPCO Security Systems

Freedom F-64 Installation Instructions

 

Image 27
Contents Napco Freedom FImportant Notice Table of Contents Page WI1501A 9/06 IntroductionWI1501A 9/06 5  SpecificationsSystem Components Ordering InformationSummary of UL Requirements WI1501A 9/06 7 Wheelock AH-12WP Control Panel InstallationWI1501A 9/06 9  WiringRestore the wireless point close the loop Testing the SystemTransformer Wiring ConnectionsSIREN/BELL Power Auxiliary PowerEarth Ground Remote BUSEZ Zone Doublingtm Configuration Basic Zone ConfigurationWire Smoke Detector Wiring Wire Smoke DetectorsWI1501A 9/06 15  Telephone LinesKeypad / Touchpad Messages Keypad / Touchpad MessagesAC Failure AC-Fail Report Delay GlossaryWI1501A 9/06 17  Alarm Outputs Ambush Touchpad Ambush Ambush Codes Enable Global AmbushAreas Zone Area 1-Zone Area 4 Priority Area Arming WI1501A 9/06 19  Auto Status DisableBackup Report on Telco 1/Telco BatteryChime Zone Chirp Output on Keyfob Arm/DisarmCold Start WI1501A 9/06 21  Data FormatDate/Time Digital Dialer Test Dial-Tone Detection Disable Auto Dial-Tone DetectionDigital Dialer Report Enter/Exit Test Mode Dealer Security CodeWI1501A 9/06 23  Enable CP-01 Limits Enable TCP/IP CommunicationsEasy Exit WI1501A 9/06 25  Keyfob Control of Relay Groups 1 Keyfob Arm/Disarm chirp of Alarm OutputFire Verification Not for use in California GEM-PrintWI1501A 9/06 27  Page 28WI1501A 9/06 WI1501A 9/06 29  Page 30WI1501A 9/06 Subscriber ID Numbers Account Number Sound Alarm On Exit ErrorSuppress Bypass Icon When Armed WI1501A 9/06 31 Wire, 4-Wire Smoke Detectors See Smoke Detectors Hour Zone Test Timer Cancel Next Test Timer Report on Any ReportTimeout WI1501A 9/06 33  Zone Area 1-4 See Areas Trouble on Open Trouble on Short Not for UL installationsTrouble Fire Trouble Zone DirectoryZone Status WI1501A 9/06 35 STANDBY-BATTERY Calculation Worksheet Alarm current drawn in alarmStandby Time in Hours Box Standby Time1 WI1501A 9/06 37  Wiring LegendLocation Programming AddressWI1501A 9/06 39  Out of Box Panel Operation Factory Default DescriptionOut of Box Panel Operation Prior to CP-01 Changes WI1501A 9/06 41 FCC Statement WI1501A 9/06 43  Freedom F-64 Wiring DiagramNapco Limited Warranty

WI1501A specifications

Napco Security Technologies has long been a trusted name in the security industry, and their WI1501A model is no exception. This advanced wireless intrusion detection and communication solution is engineered to offer exceptional performance, reliability, and versatility, making it a popular choice for both residential and commercial applications.

One of the standout features of the Napco WI1501A is its innovative wireless technology. The unit operates on a robust 433 MHz frequency, ensuring a stable connection with minimal interference from other devices. This frequency allows the WI1501A to cover a significant range, providing flexibility in installation without the constraint of wired connections. Its wireless capability simplifies the installation process, allowing for quick setup and repositioning if necessary.

The WI1501A is equipped with advanced motion detection technology. It utilizes passive infrared (PIR) sensors to accurately detect movement within its monitored area. These sensors are designed to minimize false alarms, ensuring that users are only alerted when genuine activity is identified. This feature is particularly valuable in environments with pets or fluctuating temperature conditions, as the sensors can distinguish between legitimate threats and non-threatening movements.

Another essential aspect of the WI1501A is its integration capabilities. It seamlessly integrates with Napco's central monitoring systems and can be customized to work with various other security components. This interoperability allows users to expand their security systems without worrying about compatibility issues.

Durability is also a key characteristic of the Napco WI1501A. Designed to withstand different environmental conditions, the unit is suitable for both indoor and outdoor installations. Its robust housing protects it from dust and moisture, ensuring long-lasting performance even in challenging settings.

The WI1501A boasts a user-friendly interface and is compatible with smartphone applications, enabling users to monitor their security systems remotely. Customizable settings allow users to tailor the system to their specific needs, whether they require immediate alerts or scheduled monitoring.

In conclusion, Napco Security Technologies' WI1501A is a versatile, reliable, and technologically advanced security solution. With its wireless technology, advanced motion detection, integration capabilities, durability, and user-friendly features, it represents a compelling option for anyone looking to enhance their security measures.