Napco Security Technologies WI1501A installation instructions Remote BUS, Earth Ground

Page 12

Page 12

WI1501A 9/06

REMOTE BUS

& Earth Ground

REMOTE BUS

ADDITIONAL

EZMs

(GEM-RP1CAe2)

2 LINE KEYPAD

Example:

F-64TP Touchpad

NOTE: Refer to the EZM Installation Instructions for specific wiring information.

AVAILABLE DEVICES

AVAILABLE DEVICES

1. KEYPADS: GEM-RP2AS & GEM-RP1CAe2

 

2. X-10 INTERFACE: GEM-X10

1.

TOUCHPADS / KEYPADS: (3 maximum) F-64PROG:32-Character

3. WIRED ZONE EXPANDER: GEM-EZM816LCD Burg

& Fire Programmer*, F-64TP:Wireless Touchpad, F-

 

 

4. WIRELESS RECEIVERS: GEM RECV8,64TPGGEM-RECV16Garage&DoorGEM-RECV96Touchpad*,F-64TPBRBedroom Touchpad, F-

5. RELAY MODULE: RM3008

 

64TP-HHardwired Touchpad*

6. VOICE INTERFACE: GEM-EVA

 

 

 

7. TELEPHONE INTERFACE: WIZARD2. X-10 INTERFACE: GEM-X10 (16 devices maximum)*

3. WIRED ZONE EXPANDER: GEM-EZM4/8EX*, GEM-EZM4/8* (64 zones maximum)

4. WIRELESS RECEIVERS: GEM-RECV8, GEM-RECV16, GEM- RECV96 (64 zones maximum)

5. RELAY MODULE: RM3008 (16 relays maximum)

6. VOICE INTERFACE: GEM-EVA 1*

7. TELEPHONE INTERFACE: WIZARD IIe*

Wiring Connections: Remote Bus

Connect the available devices as shown above to the remote bus terminals (9, 10, 11 & 12). Observe the correct color wire connections. When connecting the Touchpads, first configure them accordingly (refer to the Touchpad Configuration Mode in WI1502). Up to four Touchpads may be connected if the longest cable run from the panel, to the farthest Touchpad (daisy chained or home-run) is less than 1000 feet. The maximum distance for seven key- pads/Touchpads is 300 feet using 22 AWG. wire. NOTE: When running keypad/Touchpad wire, avoid wiring parallel to other types of wiring.

EARTH GROUND

Connect the control panel EARTH GROUND screw to a metal cold-water pipe using at least a #16 AWG. wire. Do not use a gas pipe, plastic pipe or AC ground connections. Also, connect the circuit board to the metal enclosure. Connect a wire with a ground lug crimped or soldered onto one end of the EARTH GROUND screw to the cabinet.

NOTE: Grounding connections should avoid bends in the grounding wire whenever possible.

NOTE: Do not use a gas pipe, plastic pipe or AC ground connections.

* Not evaluated by UL

Freedom F-64 Installation Instructions

L NAPCO Security Systems

 

Image 12
Contents Freedom F NapcoImportant Notice Table of Contents Introduction Page WI1501A 9/06Specifications WI1501A 9/06 5 Ordering Information System ComponentsSummary of UL Requirements WI1501A 9/06 7 Wheelock AH-12WP Installation Control PanelWiring WI1501A 9/06 9 Testing the System Restore the wireless point close the loopWiring Connections SIREN/BELL PowerAuxiliary Power TransformerRemote BUS Earth GroundBasic Zone Configuration EZ Zone Doublingtm ConfigurationWire Smoke Detectors Wire Smoke Detector WiringTelephone Lines WI1501A 9/06 15 Keypad / Touchpad Messages Keypad / Touchpad MessagesAC Failure AC-Fail Report Delay GlossaryWI1501A 9/06 17  Alarm Outputs Ambush Touchpad Ambush Ambush Codes Enable Global AmbushAreas Zone Area 1-Zone Area 4 Priority Area Arming Auto Status Disable Backup Report on Telco 1/TelcoBattery WI1501A 9/06 19 Chime Zone Chirp Output on Keyfob Arm/DisarmCold Start WI1501A 9/06 21  Data FormatDate/Time Dial-Tone Detection Disable Auto Dial-Tone Detection Digital Dialer Report Enter/Exit Test ModeDealer Security Code Digital Dialer TestWI1501A 9/06 23  Enable CP-01 Limits Enable TCP/IP CommunicationsEasy Exit WI1501A 9/06 25  Keyfob Arm/Disarm chirp of Alarm Output Fire Verification Not for use in CaliforniaGEM-Print Keyfob Control of Relay Groups 1WI1501A 9/06 27  Page 28WI1501A 9/06 WI1501A 9/06 29  Page 30WI1501A 9/06 Sound Alarm On Exit Error Suppress Bypass Icon When ArmedWI1501A 9/06 31  Subscriber ID Numbers Account NumberWire, 4-Wire Smoke Detectors See Smoke Detectors Hour Zone Test Timer Cancel Next Test Timer Report on Any ReportTimeout WI1501A 9/06 33  Trouble on Open Trouble on Short Not for UL installations Trouble Fire TroubleZone Directory Zone Area 1-4 See AreasWI1501A 9/06 35  Zone StatusSTANDBY-BATTERY Calculation Worksheet Alarm current drawn in alarmStandby Time in Hours Box Standby Time1 Wiring Legend WI1501A 9/06 37 Programming Address LocationWI1501A 9/06 39  Factory Default Description Out of Box Panel OperationWI1501A 9/06 41  Out of Box Panel Operation Prior to CP-01 ChangesFCC Statement Freedom F-64 Wiring Diagram WI1501A 9/06 43 Napco Limited Warranty

WI1501A specifications

Napco Security Technologies has long been a trusted name in the security industry, and their WI1501A model is no exception. This advanced wireless intrusion detection and communication solution is engineered to offer exceptional performance, reliability, and versatility, making it a popular choice for both residential and commercial applications.

One of the standout features of the Napco WI1501A is its innovative wireless technology. The unit operates on a robust 433 MHz frequency, ensuring a stable connection with minimal interference from other devices. This frequency allows the WI1501A to cover a significant range, providing flexibility in installation without the constraint of wired connections. Its wireless capability simplifies the installation process, allowing for quick setup and repositioning if necessary.

The WI1501A is equipped with advanced motion detection technology. It utilizes passive infrared (PIR) sensors to accurately detect movement within its monitored area. These sensors are designed to minimize false alarms, ensuring that users are only alerted when genuine activity is identified. This feature is particularly valuable in environments with pets or fluctuating temperature conditions, as the sensors can distinguish between legitimate threats and non-threatening movements.

Another essential aspect of the WI1501A is its integration capabilities. It seamlessly integrates with Napco's central monitoring systems and can be customized to work with various other security components. This interoperability allows users to expand their security systems without worrying about compatibility issues.

Durability is also a key characteristic of the Napco WI1501A. Designed to withstand different environmental conditions, the unit is suitable for both indoor and outdoor installations. Its robust housing protects it from dust and moisture, ensuring long-lasting performance even in challenging settings.

The WI1501A boasts a user-friendly interface and is compatible with smartphone applications, enabling users to monitor their security systems remotely. Customizable settings allow users to tailor the system to their specific needs, whether they require immediate alerts or scheduled monitoring.

In conclusion, Napco Security Technologies' WI1501A is a versatile, reliable, and technologically advanced security solution. With its wireless technology, advanced motion detection, integration capabilities, durability, and user-friendly features, it represents a compelling option for anyone looking to enhance their security measures.