Napco Security Technologies WI1501A Wire, 4-Wire Smoke Detectors See Smoke Detectors Hour Zone

Page 32

Glossary

Page 32

WI1501A 9/06

System Troubles (Global and Area); Wireless Low Battery; Wireless Supervisory

System troubles may be programmed to report to any telephone number and/or activate any output. Also program Subscriber ID Numbers, Telephone Numbers, and Report Codes for each system trouble.

2-Wire, 4-Wire Smoke Detectors See Smoke Detectors

24-Hour Zone

A zone selected for "24-Hour Zone" that provides protection at all times, whether or not the system is armed. If "Alarm Output", "Pulsed Alarm Output", "PGM1 Output", "PGM2 Output" and "Keypad Sounder on Alarm" are not selected, then the zone is programmed for silent alarm. In this case, there will be no indication on the Touchpad/keypad if the zone is tripped. A 24-Hour Zone will be reset when the zone fault has been cleared and the area has been armed and disarmed. Note: Do not program a Day Zone as a 24-Hour Zone.

24 Hour Day Zone Trouble--Normally used for a hidden N/C panic button that when pressed, trips an alarm. Switch open = alarm. Short or cut in the loop = trouble.

Tamper; EZM Tamper; Keypad Tamper; Touchpad Tamper; RF Tamper; Wireless Tamper

Removing the cover of an expansion zone module will cause the sounder to pulse and the "SYS/TRBL" reminder to flash. The Touch- pad will display "SYSTEM TROUBLE/E13-NN SERVICE", where "NN" denotes the module number. Press RESET to silence the sounder ("SYSTEM READY" will display). Correct the problem, then select RESET SYSTEM TBL to manually reset the system trouble display. Removing a Touchpad from the wall causes a similar system trouble indication. The Touchpad will display "SYSTEM TROUBLE/E11-NN SERVICE", where "NN" denotes the Touchpad number. Press RESET to silence the sounder ("SYSTEM READY" will display). To manually reset the system trouble, correct the problem then select RESET SYSTEM TBL.

Note: If either of the tamper conditions is not corrected within 5 minutes, the system trouble will again display at the Touchpad. A Tamper condition can be programmed to activate the burglary output and/or report using its associated system Report Code. In wireless installations, when displaying RF transmitter status, a "Tamper" indication denotes that the transmitter case is open. Note: The F- 64PROG tamper is enabled by cutting jumper JP1 in the keypad.

TCP/IP Communications See Enable TCP/IP Communications

Telco Fail See Enable Line-Fault Test

Telco Line Test Delay See Enable Telephone Line-Fault Test; Time Selection

Telephone Numbers

To report to a central station, Telephone Number 1 must be programmed. Telephone Number 2 is programmed for Backup Reporting; Telephone Number 3 is programmed for Double or Split Reporting by selecting "Report Event Telco 3" and "Report Restore Telco 3" in SYSTEM OPTIONS and ZONE OPTIONS.

Private telephone systems may require a Dial-Tone Detection "E" or Pre-Dial Delay "D", followed by an access number to obtain an outside line. (See Access Number for Outside Line).

It should be noted here that the telephone number need not actually start in the first location shown, and may not end in the last. Extra locations have been provided to allow for one or more prefix digits: a Pre-Dial Delay "D" or a Dial-Tone Detection "E". What is important is that the telephone number, with its associated Pre-Dial Delay, Access Number, and Dial-Tone Detection, be wholly contained within that group of locations, and that they be in their proper sequence. Note: In UL Installations, do not program more than one "D" before the telephone number.

Test Timer; Cancel Next Test Timer Report on Any Report

A Digital Dialer Test (Central Station Communication Test) can be manually initiated from the Touchpad Menu Mode. Press MENU until

"DIGITAL

DIALER

TEST

Y/N" is displayed and then press YES to initiate the transmission of a Test Timer signal. Note: The option

"DIGITAL

DIALER

TEST

Y/N" will appear in the Touchpad Menu Mode list only if Report Test Timer on Telco1 or Telco 3 is

programmed.

 

 

To program an weekly Test Timer schedule that automatically reports to the Central Station on a scheduled day(s) at a scheduled time, program the day(s) and time for the schedule via the Easy Menu Driven Program Mode ("TEST TIMER") or by using Napco's Quickloader Software. Note: If "TEST TIMER" is enabled via the Easy Menu Driven Program Mode, Report Test Timer on Telco1 or Telco 3 is auto- matically enabled.

If Cancel Next Test Timer Report on Any Report is programmed, any report will cause the next test-timer transmission to be aborted, however subsequent test-timer transmissions will report as scheduled. Do not program this feature in UL installations. See glossary entry "Keypad Digital Dialer Test".

Timeout

Specifies the length of time that an alarm, alert, or delay will remain active. See Time Selection.

Freedom F-64 Installation Instructions

L NAPCO Security Systems

 

Image 32
Contents Freedom F NapcoImportant Notice Table of Contents Introduction Page WI1501A 9/06Specifications WI1501A 9/06 5 Ordering Information System ComponentsWheelock AH-12WP Summary of UL RequirementsWI1501A 9/06 7  Installation Control PanelWiring WI1501A 9/06 9 Testing the System Restore the wireless point close the loopWiring Connections SIREN/BELL PowerAuxiliary Power TransformerRemote BUS Earth GroundBasic Zone Configuration EZ Zone Doublingtm ConfigurationWire Smoke Detectors Wire Smoke Detector WiringTelephone Lines WI1501A 9/06 15 Keypad / Touchpad Messages Keypad / Touchpad MessagesWI1501A 9/06 17  AC Failure AC-Fail Report DelayGlossary Areas Zone Area 1-Zone Area 4 Priority Area Arming Alarm OutputsAmbush Touchpad Ambush Ambush Codes Enable Global Ambush Auto Status Disable Backup Report on Telco 1/TelcoBattery WI1501A 9/06 19 Cold Start Chime ZoneChirp Output on Keyfob Arm/Disarm Date/Time WI1501A 9/06 21 Data Format Dial-Tone Detection Disable Auto Dial-Tone Detection Digital Dialer Report Enter/Exit Test ModeDealer Security Code Digital Dialer TestWI1501A 9/06 23  Easy Exit Enable CP-01 LimitsEnable TCP/IP Communications WI1501A 9/06 25  Keyfob Arm/Disarm chirp of Alarm Output Fire Verification Not for use in CaliforniaGEM-Print Keyfob Control of Relay Groups 1WI1501A 9/06 27  Page 28WI1501A 9/06 WI1501A 9/06 29  Page 30WI1501A 9/06 Sound Alarm On Exit Error Suppress Bypass Icon When ArmedWI1501A 9/06 31  Subscriber ID Numbers Account NumberTimeout Wire, 4-Wire Smoke Detectors See Smoke Detectors Hour ZoneTest Timer Cancel Next Test Timer Report on Any Report WI1501A 9/06 33  Trouble on Open Trouble on Short Not for UL installations Trouble Fire TroubleZone Directory Zone Area 1-4 See AreasWI1501A 9/06 35  Zone StatusStandby Time in Hours Box Standby Time1 STANDBY-BATTERY Calculation WorksheetAlarm current drawn in alarm Wiring Legend WI1501A 9/06 37 Programming Address LocationWI1501A 9/06 39  Factory Default Description Out of Box Panel OperationWI1501A 9/06 41  Out of Box Panel Operation Prior to CP-01 ChangesFCC Statement Freedom F-64 Wiring Diagram WI1501A 9/06 43 Napco Limited Warranty

WI1501A specifications

Napco Security Technologies has long been a trusted name in the security industry, and their WI1501A model is no exception. This advanced wireless intrusion detection and communication solution is engineered to offer exceptional performance, reliability, and versatility, making it a popular choice for both residential and commercial applications.

One of the standout features of the Napco WI1501A is its innovative wireless technology. The unit operates on a robust 433 MHz frequency, ensuring a stable connection with minimal interference from other devices. This frequency allows the WI1501A to cover a significant range, providing flexibility in installation without the constraint of wired connections. Its wireless capability simplifies the installation process, allowing for quick setup and repositioning if necessary.

The WI1501A is equipped with advanced motion detection technology. It utilizes passive infrared (PIR) sensors to accurately detect movement within its monitored area. These sensors are designed to minimize false alarms, ensuring that users are only alerted when genuine activity is identified. This feature is particularly valuable in environments with pets or fluctuating temperature conditions, as the sensors can distinguish between legitimate threats and non-threatening movements.

Another essential aspect of the WI1501A is its integration capabilities. It seamlessly integrates with Napco's central monitoring systems and can be customized to work with various other security components. This interoperability allows users to expand their security systems without worrying about compatibility issues.

Durability is also a key characteristic of the Napco WI1501A. Designed to withstand different environmental conditions, the unit is suitable for both indoor and outdoor installations. Its robust housing protects it from dust and moisture, ensuring long-lasting performance even in challenging settings.

The WI1501A boasts a user-friendly interface and is compatible with smartphone applications, enabling users to monitor their security systems remotely. Customizable settings allow users to tailor the system to their specific needs, whether they require immediate alerts or scheduled monitoring.

In conclusion, Napco Security Technologies' WI1501A is a versatile, reliable, and technologically advanced security solution. With its wireless technology, advanced motion detection, integration capabilities, durability, and user-friendly features, it represents a compelling option for anyone looking to enhance their security measures.