Monessen Hearth HDV500NV/PV manual Horizontal with vertical rise through-the-wall applications

Page 20

HDV Series Direct Vent Gas Fireplace

ventING installation

The maximum number of 45° elbows permitted per side wall installation is two (2). These elbows can be installed in either the vertical or horizontal run.

For each 45° elbow installed in the horizontal run, the length of the horizontal run MUST be reduced by 18" (45 cm). This does not apply if the 45° elbows are installed on the vertical part of the vent system.

The maximum number of elbow degrees in a system is 270°. Figure 24

1 + 2 + 3 + 4 = 270°

 

 

 

1

 

1

 

 

 

 

2

 

2

 

 

 

 

3

 

3

 

 

 

 

4

 

4

 

 

 

 

 

 

 

FP1180

Example:

Elbow 1

=

90°

 

Elbow 2

=

45°

 

Elbow 3

=

45°

 

Elbow 4

=

90°

Total Angular Variation

=

270°

Figure 24 -

Maximum Elbow Usage

Horizontal with vertical rise (through-the-wall) applications

1.Locate and cut the vent opening in the wall. For com- bustible walls first frame in opening.

Combustible Interior Walls: Cut a 12Z\x"H x 10Z\x" W hole through the interior wall.

Combustible Exterior Walls: Cut a 10Z\x"H x 10Z\x"W square hole through the exterior wall frame. Figure 25

Noncombustible Walls: Hole opening should be 8Z\x" (216mm) in diameter.

2.The center of the hole should align with the center line of the horizontal rigid vent pipe end. Allow 1/4" minimum rise per foot. Figure 25

10Z\x"

(267 mm)

10Z\x"

(267 mm)

Framing

Combustible Wall

 

8Z\x"

 

 

 

(216 mm)

 

 

 

 

 

 

 

 

VO584-100

 

 

 

 

 

 

 

 

 

 

 

 

Figure 25 -

Noncombustible Wall

 

 

 

 

 

 

Exterior Wall Framing Dimensions

20

56D3048

Image 20
Contents HDV Series Direct Vent Gas Fireplace HDV Series Direct Vent Gas Fireplace Owner Important Safety InformationInstaller Code Approval Never connect unit to private non-utilityGas wells. This gas is commonly known As wellhead gasProduct Specifications Gas Specifications & Orifice SizeHigh Elevations GAS pressuresFireplace and Framing Dimensions PRE-INSTALLATION Information Before You StartFireplace framing Cold Climate InsulationPRE-INSTALLATION Information Fireplace LocationMantel clearances ClearancesClearances to combustibles Finishing Material Do not remove insulation boardOptional TOP Vent Installation Installation precautions Failure to follow these instructions will void the warrantyVenting Installation Combustible Clearance to Venting PipesInstallation planning For horizontal terminationMinimum distances Venting installationInside Corner Detail How To Use The Vent Graph 10 1214 16Rear Wall Vent installation 5 x 8 Venting only Do not recess vent termination into any Wall. This will cause a fire hazardMaximum Three 3 90 Elb ows Horizontal with vertical rise through-the-wall applications Below Grade Installations Vertical through-the-roof applica- tions Flat ceiling installation Installation for vertical termina- tionAbove the first floor, including storage spaces and closets Flex Venting Installation Outside pipeFlex Venting Installation Install gas piping to fireplace location Check gas typeNatural Gas Propane/LPCheck GAS Pressure and Electrical Installation Millivolt Electrical WiringDo not use open flame to check for gas LeaksElectrical installation millivolt Remote Wall mounted Switch for millivolt valves onlyWhat to do if YOU Smell GAS Initial lightingWith open flame Approved leak testing methodNever check for gas leak Pilot position Main burner switchLighting the burner Do not use open flame to check for gas leaks Label all wires before disconnecting whenServicing controls. Wiring errors can cause Signature Command Electrical Installation Command Center Wall InstallationOptional FAN Blower System AC BoxOperating Instructions Signature Command Switch Box OPERATing InstructionsSignature Command System Operation Instructions Features Command CenterControl Board AC Interface Board OptionalKey Combinations for System Settings FUNCTIONS/OPERATION Command Center OperationsSelf Diagnostics Chart Canopy Installation Reinstalling clamps, keep fingers clearCanopy & Glass Frame Glass Frame RemovalFloor brick Installation Install logs and rock wool ember material in fireboxLOG Installation LOG Installation All Logs on Burner with Rock Wool Burner, Pilot and Control Compart- ment Pilot FlameBurner Burner FlameVent System Glass DoorLogs Rock woolTroubleshooting Standing Pilot IgnitionTroubleshooting Troubleshooting Signature Command SystemFirebox Components Description Qty HDV500Replacement Parts Standing Pilot Millivolt PartsHDV500NV HDV500PV 5a,b,c 13, 14 HDV500 Logs Accessories / Field Installed Options Replacement Parts Vent Components for 4 X 6B\Vent Components for 5 X HDV Series Direct Vent Gas Fireplace MassachusettsHDV Series Dir ct Vent Gas Fireplace Lifetime Warranty Five Year WarrantyBasic Warranty If Warranty Service is NeededEfficiency Ratings Mhsc

HDV500NV/PV specifications

The Monessen Hearth HDV500NV/PV is a powerful and efficient gas fireplace designed to enhance the warmth and ambiance of any living space. This model is part of Monessen's esteemed lineup of vented gas fireplaces, which are known for their elegant designs and performance. The HDV500NV/PV specifically is designed for those who desire both aesthetic appeal and functional heating.

One of the standout features of the HDV500NV/PV is its versatile installation options. It can be vented vertically or horizontally, providing flexibility for various home layouts. This adaptability makes it an ideal choice for homeowners looking to retrofit an existing space or build a new one. With a powerful input rating of up to 30,000 BTUs, it delivers exceptional heat output and efficiently warms the room, ensuring comfort during colder months.

The fireplace boasts a realistic flame presentation, thanks to its innovative burner technology. The advanced burner system creates flickering flames that mimic traditional wood-burning fireplaces, enhancing the overall aesthetic. Additionally, the HDV500NV/PV is equipped with a ceramic glass front that not only showcases the beautiful flames but also provides a clear view while maintaining safety standards.

For convenience, the HDV500NV/PV features a simple, user-friendly remote control that allows homeowners to adjust the flame height and heat output with ease. This feature adds a layer of comfort, as it eliminates the need to manually operate the fireplace for temperature adjustments. The optional adjustable thermostat enhances this convenience, allowing for automated temperature regulation.

The design of the HDV500NV/PV is equally impressive. Its clean lines and elegant finish make it a striking focal point in any room. Available in various styles and trims, it can seamlessly integrate into various home decors, from modern to traditional.

Safety is also a priority with the HDV500NV/PV. It includes built-in safety features such as a gas shut-off valve and an oxygen depletion sensor, providing peace of mind for users.

In summary, the Monessen Hearth HDV500NV/PV is a versatile, efficient, and aesthetically pleasing gas fireplace that combines advanced technologies with user convenience. Its realistic flame presentation, powerful heating capabilities, and stylish design make it a perfect choice for enhancing any home environment.