Monessen Hearth HDV500NV/PV manual Maximum Three 3 90 Elb ows

Page 19

Venting installation

HDV Series Direct Vent Gas Fireplace

WARNING

When installing the appliance as a rear vent unit, the 90°, 45° transition elbow attached directly to the rear of the unit is NOT INCLUDED in the following criteria and calculations, and unless specifically mentioned should be ignored when calculating venting layouts.

The maximum number of 90° elbows per side wall

installation is three (3). Figure 20

If a 90° elbow is fitted directly on top of the fireplace

A: 10’

B: 7’

flange, the maximum horizontal vent run before the ter-

 

 

 

mination or a vertical rise is 36" (914 mm). Figure 21

 

 

3 x 90°

Elbows

3 x 90°

Elbows

Figure 20 -

Maximum Three (3) 90° Elbows

Per Installation

FP1176

36"

(914 mm)

Max.

36"

(914 mm)

Max.

Figure 21 -

 

Maximum Horizontal Run with No Rise

FP1177

If a 90° elbow is used in the horizontal vent run (level height maintained) the horizontal vent length is reduced by 36" (914 mm) (Fig. 21 A and B) This does not apply if the 90° elbows are used to increase or redirect a vertical rise. Figure 22

Horizontal 90° Elbow = 3' Reduction

A + B = 17' Maximum

7’6”

Figure 22 -

Maximum Vent Run with Elbows

FP1959

Example: According to the vent graph (page 17) the maxi- mum horizontal vent length in a system with a 7.5' vertical rise is 20’ (6 m) and if a 90° elbow is required in the hori- zontal vent it must be reduced to 17' (5.2 m).

In Figures 22 and 24, Dimension A plus B must not be greater than 17' (5.2 m).

90°

AB

7’6”

FP2466

Figure 23 -

Horizontal Run Reduction

56D3048

19

Image 19
Contents HDV Series Direct Vent Gas Fireplace HDV Series Direct Vent Gas Fireplace Installer Important Safety InformationOwner As wellhead gas Code ApprovalNever connect unit to private non-utility Gas wells. This gas is commonly knownGAS pressures Product SpecificationsGas Specifications & Orifice Size High ElevationsFireplace and Framing Dimensions Cold Climate Insulation PRE-INSTALLATION InformationBefore You Start Fireplace framingFireplace Location PRE-INSTALLATION InformationClearances to combustibles ClearancesMantel clearances Do not remove insulation board Finishing MaterialOptional TOP Vent Installation Failure to follow these instructions will void the warranty Installation precautionsCombustible Clearance to Venting Pipes Venting InstallationFor horizontal termination Installation planningInside Corner Detail Venting installationMinimum distances 10 1214 16 How To Use The Vent GraphRear Wall Vent installation 5 x 8 Venting only Wall. This will cause a fire hazard Do not recess vent termination into anyMaximum Three 3 90 Elb ows Horizontal with vertical rise through-the-wall applications Below Grade Installations Vertical through-the-roof applica- tions Installation for vertical termina- tion Flat ceiling installationAbove the first floor, including storage spaces and closets Outside pipe Flex Venting InstallationFlex Venting Installation Check gas type Install gas piping to fireplace locationPropane/LP Natural GasLeaks Check GAS Pressure and Electrical Installation MillivoltElectrical Wiring Do not use open flame to check for gasRemote Wall mounted Switch for millivolt valves only Electrical installation millivoltInitial lighting What to do if YOU Smell GASNever check for gas leak Approved leak testing methodWith open flame Lighting the burner Main burner switchPilot position Servicing controls. Wiring errors can cause Label all wires before disconnecting whenDo not use open flame to check for gas leaks Command Center Wall Installation Signature Command Electrical InstallationAC Box Optional FAN Blower SystemOperating Instructions Signature Command OPERATing Instructions Switch BoxAC Interface Board Optional Signature Command System Operation Instructions FeaturesCommand Center Control BoardKey Combinations for System Settings Self Diagnostics Chart Command Center OperationsFUNCTIONS/OPERATION Glass Frame Removal Canopy InstallationReinstalling clamps, keep fingers clear Canopy & Glass FrameInstall logs and rock wool ember material in firebox Floor brick InstallationLOG Installation LOG Installation All Logs on Burner with Rock Wool Burner Flame Burner, Pilot and Control Compart- mentPilot Flame BurnerRock wool Vent SystemGlass Door LogsStanding Pilot Ignition TroubleshootingTroubleshooting Signature Command System TroubleshootingDescription Qty HDV500 Firebox ComponentsStanding Pilot Millivolt Parts Replacement PartsHDV500NV HDV500PV 5a,b,c 13, 14 HDV500 Logs Accessories / Field Installed Options Vent Components for 4 X 6B\ Replacement PartsVent Components for 5 X HDV Series Direct Vent Gas Fireplace MassachusettsHDV Series Dir ct Vent Gas Fireplace If Warranty Service is Needed Lifetime WarrantyFive Year Warranty Basic WarrantyMhsc Efficiency Ratings

HDV500NV/PV specifications

The Monessen Hearth HDV500NV/PV is a powerful and efficient gas fireplace designed to enhance the warmth and ambiance of any living space. This model is part of Monessen's esteemed lineup of vented gas fireplaces, which are known for their elegant designs and performance. The HDV500NV/PV specifically is designed for those who desire both aesthetic appeal and functional heating.

One of the standout features of the HDV500NV/PV is its versatile installation options. It can be vented vertically or horizontally, providing flexibility for various home layouts. This adaptability makes it an ideal choice for homeowners looking to retrofit an existing space or build a new one. With a powerful input rating of up to 30,000 BTUs, it delivers exceptional heat output and efficiently warms the room, ensuring comfort during colder months.

The fireplace boasts a realistic flame presentation, thanks to its innovative burner technology. The advanced burner system creates flickering flames that mimic traditional wood-burning fireplaces, enhancing the overall aesthetic. Additionally, the HDV500NV/PV is equipped with a ceramic glass front that not only showcases the beautiful flames but also provides a clear view while maintaining safety standards.

For convenience, the HDV500NV/PV features a simple, user-friendly remote control that allows homeowners to adjust the flame height and heat output with ease. This feature adds a layer of comfort, as it eliminates the need to manually operate the fireplace for temperature adjustments. The optional adjustable thermostat enhances this convenience, allowing for automated temperature regulation.

The design of the HDV500NV/PV is equally impressive. Its clean lines and elegant finish make it a striking focal point in any room. Available in various styles and trims, it can seamlessly integrate into various home decors, from modern to traditional.

Safety is also a priority with the HDV500NV/PV. It includes built-in safety features such as a gas shut-off valve and an oxygen depletion sensor, providing peace of mind for users.

In summary, the Monessen Hearth HDV500NV/PV is a versatile, efficient, and aesthetically pleasing gas fireplace that combines advanced technologies with user convenience. Its realistic flame presentation, powerful heating capabilities, and stylish design make it a perfect choice for enhancing any home environment.