Monessen Hearth HDV500NV/PV manual HDV500NV HDV500PV

Page 54

HDV Series Direct Vent Gas Fireplace

 

 

REPLACEMENT PARTS

Standing Pilot - Millivolt Parts

 

 

 

 

 

 

 

 

Ref.

Description

qty.

HDV500NV

HDV500PV

1.

Gas Valve Assy.

1

37D0117

37D0118

2.

Pilot Assy.

1

0H2048

20H2049

2C.

Replacement Thermocouple

1

37D1067

37D1067

2I.

Replacement Ignitor and Wire

1

37D1069

37D1069

2T.

Replacement Thermopile

1

37D1068

37D1068

3a.

Valve/Tee Tube

1

56D3045

56D3045

3b.

Front Burner Tube

1

56D3046

56D3046

3c.

Rear Burner Tube

1

56D3047

56D3047

4.

Flex Hose w/ Shutoff Valve

1

69D0030

69D0030

5.

Rocker Switch

1

41D0048

41D0048

6.

Piezo Ignitor

1

14D0503

14D0503

7a.

Front Injector

1

56D3059

62D3005

7b.

Rear Injector

1

62D3003

20H3143

8a.

Front Burner Assy.

1

56D3051

56D3051

8b.

Rear Burner Assy.

1

56D3052

56D3052

9.

Venturi

1

45D0600

45D0600

10.

Wire Assy. - Switch

1

44D0500

44D0500

10.

Wire Assy. - Remote

1

44D0501

44D0501

 

Accessories

 

 

 

11.

Thermostatic Remote Control

1

RCT/RCST/RCSTE,RCSIT,RCSTEB

12.

Remote Control ON/OFF

1

RCB,RCMT,WMTD

13.

Wireless Wall Thermostat

1

WWTD/TLT

 

14.

Wall Switch Kit

1

MVWS

 

15.

Wall Thermostat Kit

1

WT

 

Fuel Conversion Kits - Millivolt

Natural Gas to LP

HDV500 Kit #HCK500CKP

LP to Natural Gas

HDV500 Kit #HCK500CKN

54

56D3048

Image 54
Contents HDV Series Direct Vent Gas Fireplace HDV Series Direct Vent Gas Fireplace Important Safety Information InstallerOwner Gas wells. This gas is commonly known Code ApprovalNever connect unit to private non-utility As wellhead gasHigh Elevations Product SpecificationsGas Specifications & Orifice Size GAS pressuresFireplace and Framing Dimensions Fireplace framing PRE-INSTALLATION InformationBefore You Start Cold Climate InsulationPRE-INSTALLATION Information Fireplace LocationClearances Clearances to combustiblesMantel clearances Finishing Material Do not remove insulation boardOptional TOP Vent Installation Installation precautions Failure to follow these instructions will void the warrantyVenting Installation Combustible Clearance to Venting PipesInstallation planning For horizontal terminationVenting installation Inside Corner DetailMinimum distances How To Use The Vent Graph 10 1214 16Rear Wall Vent installation 5 x 8 Venting only Do not recess vent termination into any Wall. This will cause a fire hazardMaximum Three 3 90 Elb ows Horizontal with vertical rise through-the-wall applications Below Grade Installations Vertical through-the-roof applica- tions Flat ceiling installation Installation for vertical termina- tionAbove the first floor, including storage spaces and closets Flex Venting Installation Outside pipeFlex Venting Installation Install gas piping to fireplace location Check gas typeNatural Gas Propane/LPDo not use open flame to check for gas Check GAS Pressure and Electrical Installation MillivoltElectrical Wiring LeaksElectrical installation millivolt Remote Wall mounted Switch for millivolt valves onlyWhat to do if YOU Smell GAS Initial lightingApproved leak testing method Never check for gas leakWith open flame Main burner switch Lighting the burnerPilot position Label all wires before disconnecting when Servicing controls. Wiring errors can causeDo not use open flame to check for gas leaks Signature Command Electrical Installation Command Center Wall InstallationOptional FAN Blower System AC BoxOperating Instructions Signature Command Switch Box OPERATing InstructionsControl Board Signature Command System Operation Instructions FeaturesCommand Center AC Interface Board OptionalKey Combinations for System Settings Command Center Operations Self Diagnostics ChartFUNCTIONS/OPERATION Canopy & Glass Frame Canopy InstallationReinstalling clamps, keep fingers clear Glass Frame RemovalFloor brick Installation Install logs and rock wool ember material in fireboxLOG Installation LOG Installation All Logs on Burner with Rock Wool Burner Burner, Pilot and Control Compart- mentPilot Flame Burner FlameLogs Vent SystemGlass Door Rock woolTroubleshooting Standing Pilot IgnitionTroubleshooting Troubleshooting Signature Command SystemFirebox Components Description Qty HDV500Replacement Parts Standing Pilot Millivolt PartsHDV500NV HDV500PV 5a,b,c 13, 14 HDV500 Logs Accessories / Field Installed Options Replacement Parts Vent Components for 4 X 6B\Vent Components for 5 X HDV Series Direct Vent Gas Fireplace MassachusettsHDV Series Dir ct Vent Gas Fireplace Basic Warranty Lifetime WarrantyFive Year Warranty If Warranty Service is NeededEfficiency Ratings Mhsc

HDV500NV/PV specifications

The Monessen Hearth HDV500NV/PV is a powerful and efficient gas fireplace designed to enhance the warmth and ambiance of any living space. This model is part of Monessen's esteemed lineup of vented gas fireplaces, which are known for their elegant designs and performance. The HDV500NV/PV specifically is designed for those who desire both aesthetic appeal and functional heating.

One of the standout features of the HDV500NV/PV is its versatile installation options. It can be vented vertically or horizontally, providing flexibility for various home layouts. This adaptability makes it an ideal choice for homeowners looking to retrofit an existing space or build a new one. With a powerful input rating of up to 30,000 BTUs, it delivers exceptional heat output and efficiently warms the room, ensuring comfort during colder months.

The fireplace boasts a realistic flame presentation, thanks to its innovative burner technology. The advanced burner system creates flickering flames that mimic traditional wood-burning fireplaces, enhancing the overall aesthetic. Additionally, the HDV500NV/PV is equipped with a ceramic glass front that not only showcases the beautiful flames but also provides a clear view while maintaining safety standards.

For convenience, the HDV500NV/PV features a simple, user-friendly remote control that allows homeowners to adjust the flame height and heat output with ease. This feature adds a layer of comfort, as it eliminates the need to manually operate the fireplace for temperature adjustments. The optional adjustable thermostat enhances this convenience, allowing for automated temperature regulation.

The design of the HDV500NV/PV is equally impressive. Its clean lines and elegant finish make it a striking focal point in any room. Available in various styles and trims, it can seamlessly integrate into various home decors, from modern to traditional.

Safety is also a priority with the HDV500NV/PV. It includes built-in safety features such as a gas shut-off valve and an oxygen depletion sensor, providing peace of mind for users.

In summary, the Monessen Hearth HDV500NV/PV is a versatile, efficient, and aesthetically pleasing gas fireplace that combines advanced technologies with user convenience. Its realistic flame presentation, powerful heating capabilities, and stylish design make it a perfect choice for enhancing any home environment.