Monessen Hearth HDV500NV/PV manual MassachusettsHDV Series Dir ct Vent Gas Fireplace

Page 62

MassachusettsHDV Series Dir ct Vent Gas Fireplace

Residents Only — Please read and follow these special requirements

NOTE REGARDING VENTED PRODUCTS

This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachusetts.

Any residence with a direct vent product must have a CO detector installed in the residence.

Installation of the fireplace or vented gas log in the State of Massachusetts requires the damper to be permanently removed or welded in the fully open position.

In addition, a naturally vented gas log may not be installed in a bedroom or bathroom in the State of Massachusetts.

Flex line installation must not exceed 36 inches and must have a T shutoff valve.

NOTE REGARDING VENT FREE PRODUCTS

This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachusetts.

In addition, vent free products may not be installed in a bedroom or bathroom regardless of size or type in the State of Massachusetts.

Flex line installation must not exceed 36 inches and must have a T shutoff valve.

CARBON MONOXIDE DETECTOR REQUIREMENTS

(2)Revise 10.8.3 by adding the following additional requirements:

(a)For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:

1.Installation of carbon monoxide detectors. At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gas fitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gas fitter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors

a.In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.

b.In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed.

2.Approved Carbon Monoxide Detectors. Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.

3.Signage. A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall read, in print size no less than one-half (1/2) inch in size,

“GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS.”

4.Inspection. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.08(2)(a)1 through 4.

(b)Exemptions: The following equipment is exempt from

248 CMR 5.08(2)(a)1 through 4:

1.The equipment listed in Chapter 10 entitled "Equipment Not Required To Be Vented" in the most current edition of NFPA 54 as adopted by the Board; and

2.Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or structure used in whole or in part for residential purposes.

(c)Manufacturer requirements — Gas Equipment Venting System Provided. When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include:

1.Detailed instructions for the installation of the venting system design or the venting system components; and

2.A complete parts list for the venting system design or venting system.

(d)Manufacturer requirements — Gas Equipment Venting System Not Provided. When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identifies “special venting systems,” the following requirements shall be satisfied by the manufacturer:

1.The referenced "special venting system" instructions shall be included with the appliance or equipment installation instructions; and

2.The “special venting systems” shall be Product Approved by the Board, and the instructions for that system shall include a parts list and detailed installation instructions.

(e)A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design

62

56D3048

Image 62
Contents HDV Series Direct Vent Gas Fireplace HDV Series Direct Vent Gas Fireplace Owner Important Safety InformationInstaller Gas wells. This gas is commonly known Code ApprovalNever connect unit to private non-utility As wellhead gasHigh Elevations Product SpecificationsGas Specifications & Orifice Size GAS pressuresFireplace and Framing Dimensions Fireplace framing PRE-INSTALLATION InformationBefore You Start Cold Climate InsulationPRE-INSTALLATION Information Fireplace LocationMantel clearances ClearancesClearances to combustibles Finishing Material Do not remove insulation boardOptional TOP Vent Installation Installation precautions Failure to follow these instructions will void the warrantyVenting Installation Combustible Clearance to Venting PipesInstallation planning For horizontal terminationMinimum distances Venting installationInside Corner Detail How To Use The Vent Graph 10 1214 16Rear Wall Vent installation 5 x 8 Venting only Do not recess vent termination into any Wall. This will cause a fire hazardMaximum Three 3 90 Elb ows Horizontal with vertical rise through-the-wall applications Below Grade Installations Vertical through-the-roof applica- tions Flat ceiling installation Installation for vertical termina- tionAbove the first floor, including storage spaces and closets Flex Venting Installation Outside pipeFlex Venting Installation Install gas piping to fireplace location Check gas typeNatural Gas Propane/LPDo not use open flame to check for gas Check GAS Pressure and Electrical Installation MillivoltElectrical Wiring LeaksElectrical installation millivolt Remote Wall mounted Switch for millivolt valves onlyWhat to do if YOU Smell GAS Initial lightingWith open flame Approved leak testing methodNever check for gas leak Pilot position Main burner switchLighting the burner Do not use open flame to check for gas leaks Label all wires before disconnecting whenServicing controls. Wiring errors can cause Signature Command Electrical Installation Command Center Wall InstallationOptional FAN Blower System AC BoxOperating Instructions Signature Command Switch Box OPERATing InstructionsControl Board Signature Command System Operation Instructions FeaturesCommand Center AC Interface Board OptionalKey Combinations for System Settings FUNCTIONS/OPERATION Command Center OperationsSelf Diagnostics Chart Canopy & Glass Frame Canopy InstallationReinstalling clamps, keep fingers clear Glass Frame RemovalFloor brick Installation Install logs and rock wool ember material in fireboxLOG Installation LOG Installation All Logs on Burner with Rock Wool Burner Burner, Pilot and Control Compart- mentPilot Flame Burner FlameLogs Vent SystemGlass Door Rock woolTroubleshooting Standing Pilot IgnitionTroubleshooting Troubleshooting Signature Command SystemFirebox Components Description Qty HDV500Replacement Parts Standing Pilot Millivolt PartsHDV500NV HDV500PV 5a,b,c 13, 14 HDV500 Logs Accessories / Field Installed Options Replacement Parts Vent Components for 4 X 6B\Vent Components for 5 X HDV Series Direct Vent Gas Fireplace MassachusettsHDV Series Dir ct Vent Gas Fireplace Basic Warranty Lifetime WarrantyFive Year Warranty If Warranty Service is NeededEfficiency Ratings Mhsc

HDV500NV/PV specifications

The Monessen Hearth HDV500NV/PV is a powerful and efficient gas fireplace designed to enhance the warmth and ambiance of any living space. This model is part of Monessen's esteemed lineup of vented gas fireplaces, which are known for their elegant designs and performance. The HDV500NV/PV specifically is designed for those who desire both aesthetic appeal and functional heating.

One of the standout features of the HDV500NV/PV is its versatile installation options. It can be vented vertically or horizontally, providing flexibility for various home layouts. This adaptability makes it an ideal choice for homeowners looking to retrofit an existing space or build a new one. With a powerful input rating of up to 30,000 BTUs, it delivers exceptional heat output and efficiently warms the room, ensuring comfort during colder months.

The fireplace boasts a realistic flame presentation, thanks to its innovative burner technology. The advanced burner system creates flickering flames that mimic traditional wood-burning fireplaces, enhancing the overall aesthetic. Additionally, the HDV500NV/PV is equipped with a ceramic glass front that not only showcases the beautiful flames but also provides a clear view while maintaining safety standards.

For convenience, the HDV500NV/PV features a simple, user-friendly remote control that allows homeowners to adjust the flame height and heat output with ease. This feature adds a layer of comfort, as it eliminates the need to manually operate the fireplace for temperature adjustments. The optional adjustable thermostat enhances this convenience, allowing for automated temperature regulation.

The design of the HDV500NV/PV is equally impressive. Its clean lines and elegant finish make it a striking focal point in any room. Available in various styles and trims, it can seamlessly integrate into various home decors, from modern to traditional.

Safety is also a priority with the HDV500NV/PV. It includes built-in safety features such as a gas shut-off valve and an oxygen depletion sensor, providing peace of mind for users.

In summary, the Monessen Hearth HDV500NV/PV is a versatile, efficient, and aesthetically pleasing gas fireplace that combines advanced technologies with user convenience. Its realistic flame presentation, powerful heating capabilities, and stylish design make it a perfect choice for enhancing any home environment.