FEATURES

Command Center

Easy Access Function Operation and System Configuration

Operation Confirmation/Fault Diagnostic Indications (LED/ Buzzer)

ON/OFF/HI/Low Operation

Control Board

Electronic Ignition

Pilot Lockout safety feature

Electric Power Regeneration from Thermopile to save bat- tery

6-hour Automatic Shut Down Option

Convenient NG/LP Gas Type Conversion

Standing Pilot/Intermittent pilot Conversion

Previous settings Restoration Ability

Uninterrupted Operation During Power Outage (Automatic Battery Backup)

ON/OFF RF Remote Receiver

Optional Transmitter Learn Capability

AC Interface Board (Optional)

Easy Snap-on Design

Embedded Compact 120 VAC Adapter with Auto Battery Back up Feature

RF Receiver

To Thermopile

 

ON/OFF

To Sensor

 

 

To Sparker

NG/LP

Conversion

 

To Command Center

Control

 

Board

To Stepper Motor

 

To Valve

 

Battery Door

Command

Center

Master Switch

ON

LED

OFF

Figure 54 -

Signature Command System Components

Remote Controlled Blower, Lighting, and Auxiliary AC Out- puts

Transmitter (Optional)

 

RFSC

RTSC

RMSC

Three Flame Height Settings

X

X

X

Low battery Indication for Transmitter

X

X

X

Child Proof Lock-out

X

X

X

LCD Backlight

X

X

X

Security Codes

X

X

X

Thermostatic Control Mode

X

X

--

Three Brightness Settings for Lights

X

--

--

Three Speed Control for Blower

X

--

--

On/Off Auxiliary

X

--

--

Programmable Timer to turn blower on and off

X

--

--

BATTERY INSTALLATION

The Command Center uses four (4) "AA" batteries.

To Install Batteries:

1.Press down the battery door tabs and pull out to remove battery door.

2.Install the batteries as indicated on Command Center.

3.Close battery door by snapping in place.

4.When the four (4) batteries are installed the system is ready for use.

5.The batteries should be replaced when the LED indicates low battery.

56D3048

39

Image 39
Contents HDV Series Direct Vent Gas Fireplace HDV Series Direct Vent Gas Fireplace Important Safety Information InstallerOwner As wellhead gas Code ApprovalNever connect unit to private non-utility Gas wells. This gas is commonly knownGAS pressures Product SpecificationsGas Specifications & Orifice Size High ElevationsFireplace and Framing Dimensions Cold Climate Insulation PRE-INSTALLATION InformationBefore You Start Fireplace framingFireplace Location PRE-INSTALLATION InformationClearances Clearances to combustiblesMantel clearances Do not remove insulation board Finishing MaterialOptional TOP Vent Installation Failure to follow these instructions will void the warranty Installation precautionsCombustible Clearance to Venting Pipes Venting InstallationFor horizontal termination Installation planningVenting installation Inside Corner DetailMinimum distances 10 1214 16 How To Use The Vent GraphRear Wall Vent installation 5 x 8 Venting only Wall. This will cause a fire hazard Do not recess vent termination into anyMaximum Three 3 90 Elb ows Horizontal with vertical rise through-the-wall applications Below Grade Installations Vertical through-the-roof applica- tions Installation for vertical termina- tion Flat ceiling installationAbove the first floor, including storage spaces and closets Outside pipe Flex Venting InstallationFlex Venting Installation Check gas type Install gas piping to fireplace locationPropane/LP Natural GasLeaks Check GAS Pressure and Electrical Installation MillivoltElectrical Wiring Do not use open flame to check for gasRemote Wall mounted Switch for millivolt valves only Electrical installation millivoltInitial lighting What to do if YOU Smell GASApproved leak testing method Never check for gas leakWith open flame Main burner switch Lighting the burnerPilot position Label all wires before disconnecting when Servicing controls. Wiring errors can causeDo not use open flame to check for gas leaks Command Center Wall Installation Signature Command Electrical InstallationAC Box Optional FAN Blower SystemOperating Instructions Signature Command OPERATing Instructions Switch BoxAC Interface Board Optional Signature Command System Operation Instructions FeaturesCommand Center Control BoardKey Combinations for System Settings Command Center Operations Self Diagnostics ChartFUNCTIONS/OPERATION Glass Frame Removal Canopy InstallationReinstalling clamps, keep fingers clear Canopy & Glass FrameInstall logs and rock wool ember material in firebox Floor brick InstallationLOG Installation LOG Installation All Logs on Burner with Rock Wool Burner Flame Burner, Pilot and Control Compart- mentPilot Flame BurnerRock wool Vent SystemGlass Door LogsStanding Pilot Ignition TroubleshootingTroubleshooting Signature Command System TroubleshootingDescription Qty HDV500 Firebox ComponentsStanding Pilot Millivolt Parts Replacement PartsHDV500NV HDV500PV 5a,b,c 13, 14 HDV500 Logs Accessories / Field Installed Options Vent Components for 4 X 6B\ Replacement PartsVent Components for 5 X HDV Series Direct Vent Gas Fireplace MassachusettsHDV Series Dir ct Vent Gas Fireplace If Warranty Service is Needed Lifetime WarrantyFive Year Warranty Basic WarrantyMhsc Efficiency Ratings

HDV500NV/PV specifications

The Monessen Hearth HDV500NV/PV is a powerful and efficient gas fireplace designed to enhance the warmth and ambiance of any living space. This model is part of Monessen's esteemed lineup of vented gas fireplaces, which are known for their elegant designs and performance. The HDV500NV/PV specifically is designed for those who desire both aesthetic appeal and functional heating.

One of the standout features of the HDV500NV/PV is its versatile installation options. It can be vented vertically or horizontally, providing flexibility for various home layouts. This adaptability makes it an ideal choice for homeowners looking to retrofit an existing space or build a new one. With a powerful input rating of up to 30,000 BTUs, it delivers exceptional heat output and efficiently warms the room, ensuring comfort during colder months.

The fireplace boasts a realistic flame presentation, thanks to its innovative burner technology. The advanced burner system creates flickering flames that mimic traditional wood-burning fireplaces, enhancing the overall aesthetic. Additionally, the HDV500NV/PV is equipped with a ceramic glass front that not only showcases the beautiful flames but also provides a clear view while maintaining safety standards.

For convenience, the HDV500NV/PV features a simple, user-friendly remote control that allows homeowners to adjust the flame height and heat output with ease. This feature adds a layer of comfort, as it eliminates the need to manually operate the fireplace for temperature adjustments. The optional adjustable thermostat enhances this convenience, allowing for automated temperature regulation.

The design of the HDV500NV/PV is equally impressive. Its clean lines and elegant finish make it a striking focal point in any room. Available in various styles and trims, it can seamlessly integrate into various home decors, from modern to traditional.

Safety is also a priority with the HDV500NV/PV. It includes built-in safety features such as a gas shut-off valve and an oxygen depletion sensor, providing peace of mind for users.

In summary, the Monessen Hearth HDV500NV/PV is a versatile, efficient, and aesthetically pleasing gas fireplace that combines advanced technologies with user convenience. Its realistic flame presentation, powerful heating capabilities, and stylish design make it a perfect choice for enhancing any home environment.