Monessen Hearth HDV500NV/PV manual Key Combinations for System Settings

Page 40

SIGNATURE COMMAND SYSTEM OPERATION INSTRUCTIONS

SYSTEM CONFIGURATION/SETUP

System configuration/setup is done on the Command Center.

Intermittent/Standing Pilot Setup (Default intermittent)

1.Holding the ON button on the Command Center while turning on the master switch will toggle between standing pilot and intermittent pilot.

2.After the above operation, one beep (for standing pilot) or two beeps (for intermittent pilot) will be given as confirmation.

Six-hour Safety Shutdown Option (Default ON)

1.The system comes preset from the factory with a six (6) hour shutdown from its last command of operation. This is done to prevent the fireplace from continuing to operate if unattended. You may disable this feature if you wish.

NOTE: By disabling this feature, your fireplace may continue to operate unattended.

2.When the master switch is in the ON position (“-”), pressing the ON button and the OFF button on the Command Center simultaneously will toggle between enabling and disabling the six- hour shutdown option.

3.After the above operation, one beep (for enabling the six-hour shutdown option) or two beeps (for disabling the six-hour shutdown option) will be given as confirmation.

Remote Transmitter Learn Function (Default OFF)

1.The RF receiver button located on the control board must be in the on position before the learn function can begin. Use paper clip to depress button. One beep for RF receiver ON or two beeps for RF receiver OFF will be given as confirmation.

2.After the RF receiver is on, holding the OFF button on the Command Center while turning on the master switch will activate the learn function for the transmitter.

3.After the above operation, two beeps will be given and the green LED on the Command Cen- ter will flash for 10 seconds.

4.During the 10 seconds, press the OFF button on a transmitter to learn. Another two beeps will be given to confirm a successful learning.

Shutting Off the Standing Pilot

To shut off the standing pilot for service or summer shut down, press and hold the ON button on the Command Center for 3 seconds when the master switch is in the ON position (“-”) and the main burner is off.

Note: Pilot will resume the next time system is turned on.

Key Combinations for System Settings

Function

operation

Default Setting

Intermittent/Standing

Hold the ON button while turning on the master switch

Intermittent

Pilot Setup

(Beep once for standing pilot, twice for intermittent pilot)

Pilot

Standing Pilot Temp.

Hold the ON button 3 seconds (when the master switch

 

Shutoff

on the main burner is off)

 

RF Remote Receiver

Push the RF receiver On/Off button on the control board

RF OFF

On/Off

Beep once for ON and beep twice for OFF

 

Learn Remote

Hold the OFF button while turning on the master switch

 

Transmitter

(Beep twice then press any handheld remote button)

 

6-hour safety

Press the ON button and OFF button simultaneously

ON

shutdown setup

(Beep once for ON, twice for OFF)

 

 

 

 

40

56D3048

Image 40
Contents HDV Series Direct Vent Gas Fireplace HDV Series Direct Vent Gas Fireplace Installer Important Safety InformationOwner Code Approval Never connect unit to private non-utilityGas wells. This gas is commonly known As wellhead gasProduct Specifications Gas Specifications & Orifice SizeHigh Elevations GAS pressuresFireplace and Framing Dimensions PRE-INSTALLATION Information Before You StartFireplace framing Cold Climate InsulationPRE-INSTALLATION Information Fireplace LocationClearances to combustibles ClearancesMantel clearances Finishing Material Do not remove insulation boardOptional TOP Vent Installation Installation precautions Failure to follow these instructions will void the warrantyVenting Installation Combustible Clearance to Venting PipesInstallation planning For horizontal terminationInside Corner Detail Venting installationMinimum distances How To Use The Vent Graph 10 1214 16Rear Wall Vent installation 5 x 8 Venting only Do not recess vent termination into any Wall. This will cause a fire hazardMaximum Three 3 90 Elb ows Horizontal with vertical rise through-the-wall applications Below Grade Installations Vertical through-the-roof applica- tions Flat ceiling installation Installation for vertical termina- tionAbove the first floor, including storage spaces and closets Flex Venting Installation Outside pipeFlex Venting Installation Install gas piping to fireplace location Check gas typeNatural Gas Propane/LPCheck GAS Pressure and Electrical Installation Millivolt Electrical WiringDo not use open flame to check for gas LeaksElectrical installation millivolt Remote Wall mounted Switch for millivolt valves onlyWhat to do if YOU Smell GAS Initial lightingNever check for gas leak Approved leak testing methodWith open flame Lighting the burner Main burner switchPilot position Servicing controls. Wiring errors can cause Label all wires before disconnecting whenDo not use open flame to check for gas leaks Signature Command Electrical Installation Command Center Wall InstallationOptional FAN Blower System AC BoxOperating Instructions Signature Command Switch Box OPERATing InstructionsSignature Command System Operation Instructions Features Command CenterControl Board AC Interface Board OptionalKey Combinations for System Settings Self Diagnostics Chart Command Center OperationsFUNCTIONS/OPERATION Canopy Installation Reinstalling clamps, keep fingers clearCanopy & Glass Frame Glass Frame RemovalFloor brick Installation Install logs and rock wool ember material in fireboxLOG Installation LOG Installation All Logs on Burner with Rock Wool Burner, Pilot and Control Compart- ment Pilot FlameBurner Burner FlameVent System Glass DoorLogs Rock woolTroubleshooting Standing Pilot IgnitionTroubleshooting Troubleshooting Signature Command SystemFirebox Components Description Qty HDV500Replacement Parts Standing Pilot Millivolt PartsHDV500NV HDV500PV 5a,b,c 13, 14 HDV500 Logs Accessories / Field Installed Options Replacement Parts Vent Components for 4 X 6B\Vent Components for 5 X HDV Series Direct Vent Gas Fireplace MassachusettsHDV Series Dir ct Vent Gas Fireplace Lifetime Warranty Five Year WarrantyBasic Warranty If Warranty Service is NeededEfficiency Ratings Mhsc

HDV500NV/PV specifications

The Monessen Hearth HDV500NV/PV is a powerful and efficient gas fireplace designed to enhance the warmth and ambiance of any living space. This model is part of Monessen's esteemed lineup of vented gas fireplaces, which are known for their elegant designs and performance. The HDV500NV/PV specifically is designed for those who desire both aesthetic appeal and functional heating.

One of the standout features of the HDV500NV/PV is its versatile installation options. It can be vented vertically or horizontally, providing flexibility for various home layouts. This adaptability makes it an ideal choice for homeowners looking to retrofit an existing space or build a new one. With a powerful input rating of up to 30,000 BTUs, it delivers exceptional heat output and efficiently warms the room, ensuring comfort during colder months.

The fireplace boasts a realistic flame presentation, thanks to its innovative burner technology. The advanced burner system creates flickering flames that mimic traditional wood-burning fireplaces, enhancing the overall aesthetic. Additionally, the HDV500NV/PV is equipped with a ceramic glass front that not only showcases the beautiful flames but also provides a clear view while maintaining safety standards.

For convenience, the HDV500NV/PV features a simple, user-friendly remote control that allows homeowners to adjust the flame height and heat output with ease. This feature adds a layer of comfort, as it eliminates the need to manually operate the fireplace for temperature adjustments. The optional adjustable thermostat enhances this convenience, allowing for automated temperature regulation.

The design of the HDV500NV/PV is equally impressive. Its clean lines and elegant finish make it a striking focal point in any room. Available in various styles and trims, it can seamlessly integrate into various home decors, from modern to traditional.

Safety is also a priority with the HDV500NV/PV. It includes built-in safety features such as a gas shut-off valve and an oxygen depletion sensor, providing peace of mind for users.

In summary, the Monessen Hearth HDV500NV/PV is a versatile, efficient, and aesthetically pleasing gas fireplace that combines advanced technologies with user convenience. Its realistic flame presentation, powerful heating capabilities, and stylish design make it a perfect choice for enhancing any home environment.