cleaning and maintenance

Vent System

The fireplace and venting system should be inspected before initial use and at least annually by a qualified field service person. Inspect the external vent cap on a regular basis to make sure that no debris is interfering with the airflow. Inspect entire venting system to ensure proper function.

Glass Door

Thoroughly clean the inside of the glass door after using the fireplace for ten hours. Periodically clean the glass door as necessary.

When cleaning the glass, remember:

Do not remove the glass when hot. Allow glass to cool before removal.

NEVER use abrasive materials.

Keep children and pets a safe distance away.

Never operate the fireplace without the glass door properly secured.

Never operate the fireplace if the glass is broken.

Replace any glass that is chipped, cracked, or broken. Replacement glass door assemblies MUST be supplied by the fireplace manufacturer – No substitute materials may be used.

Handle glass door with care to avoid striking or scratching it on hard objects.

To clean glass door, follow “Glass Removal” procedure outlined in the Final Installation section. Film deposit on the inside of the glass should be cleaned off using a nontoxic, non-corrosive, non- abrasive, mild cleaning solution. Simply apply an adequate amount to the glass and wipe off with a damp cloth. After all maintenance has been completed, re-install glass door.

Logs

Leave logs installed in the fireplace for cleaning. Vacuum surface of the logs with a brush attachment. If logs must be removed for cleaning, handle carefully by holding gently at each end. Gloves are recommended to prevent skin irritation from ceramic fibers. If skin becomes irritated, wash gently with soap and water. Vacuum surface of logs with brush attachment or brush logs with a soft bristle brush (i.e. clean, dry paintbrush). To place logs back in the fireplace, see “Log Placement” found in the Final Installation section.

NOTE: Do not use cleaning fluid to clean logs.

Rock wool

Replace or add rock wool as required following installation instructions in the Final Installation sec- tion of this manual.

48

56D3048

Image 48
Contents HDV Series Direct Vent Gas Fireplace HDV Series Direct Vent Gas Fireplace Important Safety Information InstallerOwner Code Approval Never connect unit to private non-utilityGas wells. This gas is commonly known As wellhead gasProduct Specifications Gas Specifications & Orifice SizeHigh Elevations GAS pressuresFireplace and Framing Dimensions PRE-INSTALLATION Information Before You StartFireplace framing Cold Climate InsulationPRE-INSTALLATION Information Fireplace LocationClearances Clearances to combustiblesMantel clearances Finishing Material Do not remove insulation boardOptional TOP Vent Installation Installation precautions Failure to follow these instructions will void the warrantyVenting Installation Combustible Clearance to Venting PipesInstallation planning For horizontal terminationVenting installation Inside Corner DetailMinimum distances How To Use The Vent Graph 10 1214 16Rear Wall Vent installation 5 x 8 Venting only Do not recess vent termination into any Wall. This will cause a fire hazardMaximum Three 3 90 Elb ows Horizontal with vertical rise through-the-wall applications Below Grade Installations Vertical through-the-roof applica- tions Flat ceiling installation Installation for vertical termina- tionAbove the first floor, including storage spaces and closets Flex Venting Installation Outside pipeFlex Venting Installation Install gas piping to fireplace location Check gas typeNatural Gas Propane/LPCheck GAS Pressure and Electrical Installation Millivolt Electrical WiringDo not use open flame to check for gas LeaksElectrical installation millivolt Remote Wall mounted Switch for millivolt valves onlyWhat to do if YOU Smell GAS Initial lightingApproved leak testing method Never check for gas leakWith open flame Main burner switch Lighting the burnerPilot position Label all wires before disconnecting when Servicing controls. Wiring errors can causeDo not use open flame to check for gas leaks Signature Command Electrical Installation Command Center Wall InstallationOptional FAN Blower System AC BoxOperating Instructions Signature Command Switch Box OPERATing InstructionsSignature Command System Operation Instructions Features Command CenterControl Board AC Interface Board OptionalKey Combinations for System Settings Command Center Operations Self Diagnostics ChartFUNCTIONS/OPERATION Canopy Installation Reinstalling clamps, keep fingers clearCanopy & Glass Frame Glass Frame RemovalFloor brick Installation Install logs and rock wool ember material in fireboxLOG Installation LOG Installation All Logs on Burner with Rock Wool Burner, Pilot and Control Compart- ment Pilot FlameBurner Burner FlameVent System Glass DoorLogs Rock woolTroubleshooting Standing Pilot IgnitionTroubleshooting Troubleshooting Signature Command SystemFirebox Components Description Qty HDV500Replacement Parts Standing Pilot Millivolt PartsHDV500NV HDV500PV 5a,b,c 13, 14 HDV500 Logs Accessories / Field Installed Options Replacement Parts Vent Components for 4 X 6B\Vent Components for 5 X HDV Series Direct Vent Gas Fireplace MassachusettsHDV Series Dir ct Vent Gas Fireplace Lifetime Warranty Five Year WarrantyBasic Warranty If Warranty Service is NeededEfficiency Ratings Mhsc

HDV500NV/PV specifications

The Monessen Hearth HDV500NV/PV is a powerful and efficient gas fireplace designed to enhance the warmth and ambiance of any living space. This model is part of Monessen's esteemed lineup of vented gas fireplaces, which are known for their elegant designs and performance. The HDV500NV/PV specifically is designed for those who desire both aesthetic appeal and functional heating.

One of the standout features of the HDV500NV/PV is its versatile installation options. It can be vented vertically or horizontally, providing flexibility for various home layouts. This adaptability makes it an ideal choice for homeowners looking to retrofit an existing space or build a new one. With a powerful input rating of up to 30,000 BTUs, it delivers exceptional heat output and efficiently warms the room, ensuring comfort during colder months.

The fireplace boasts a realistic flame presentation, thanks to its innovative burner technology. The advanced burner system creates flickering flames that mimic traditional wood-burning fireplaces, enhancing the overall aesthetic. Additionally, the HDV500NV/PV is equipped with a ceramic glass front that not only showcases the beautiful flames but also provides a clear view while maintaining safety standards.

For convenience, the HDV500NV/PV features a simple, user-friendly remote control that allows homeowners to adjust the flame height and heat output with ease. This feature adds a layer of comfort, as it eliminates the need to manually operate the fireplace for temperature adjustments. The optional adjustable thermostat enhances this convenience, allowing for automated temperature regulation.

The design of the HDV500NV/PV is equally impressive. Its clean lines and elegant finish make it a striking focal point in any room. Available in various styles and trims, it can seamlessly integrate into various home decors, from modern to traditional.

Safety is also a priority with the HDV500NV/PV. It includes built-in safety features such as a gas shut-off valve and an oxygen depletion sensor, providing peace of mind for users.

In summary, the Monessen Hearth HDV500NV/PV is a versatile, efficient, and aesthetically pleasing gas fireplace that combines advanced technologies with user convenience. Its realistic flame presentation, powerful heating capabilities, and stylish design make it a perfect choice for enhancing any home environment.