OPTIONAL FAN BLOWER SYSTEM

Optional Fan/BlOwer System

(BLOTBLDVSC) Installation Instructions Wiring

1.Before installing the blower, wire the receptacle into an electri- cal circuit. This should be done before framing the fireplace. Wire with minimum 60° C wire in accordance with prevailing codes.

2.Remove the external junction box cover by removing the screw from the left side of the outside firebox wall. Junction box was installed at the factory.

120V AC

60Hz

Factory Supplied

Not Supplied

Junction Box

Figure 52 -

Junction Box Wiring Diagram

3.The junction box cover has a factory installed “romex” style

strain relief connector. After connecting the wires, route the wire leads through this con- nector. Refer to the wiring diagram in Figure 52.

 

To Junction Box

 

 

 

In Fireplace

 

 

Dual

 

 

Optional

 

 

AC Box

Blowers

Optional

{

(300 W

Light

WHITE

Max)

WHITE

 

BLACK

 

BLACK

 

BLACK

 

Optional

{ WHITE

Dual

AUX

 

 

GREEN

Blowers

 

 

Connector

(300 W

 

 

 

 

Pin To Control Box

Max)

Figure 53 -

 

 

 

 

 

 

 

Blower Wiring Diagram

 

 

 

Control Box

 

 

 

FP2103

WARNING

Electrical Grounding Instructions: This appliance is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three- prong receptacle.

WARNING

Electrical connections should only be performed by a qualified licensed electrician. Main power supply must be turned off before connecting the fan to the main electrical power supply or performing service.

36

56D3048

Image 36
Contents HDV Series Direct Vent Gas Fireplace HDV Series Direct Vent Gas Fireplace Important Safety Information InstallerOwner Code Approval Never connect unit to private non-utilityGas wells. This gas is commonly known As wellhead gasProduct Specifications Gas Specifications & Orifice SizeHigh Elevations GAS pressuresFireplace and Framing Dimensions PRE-INSTALLATION Information Before You StartFireplace framing Cold Climate InsulationPRE-INSTALLATION Information Fireplace LocationClearances Clearances to combustiblesMantel clearances Finishing Material Do not remove insulation boardOptional TOP Vent Installation Installation precautions Failure to follow these instructions will void the warrantyVenting Installation Combustible Clearance to Venting PipesInstallation planning For horizontal terminationVenting installation Inside Corner DetailMinimum distances How To Use The Vent Graph 10 1214 16Rear Wall Vent installation 5 x 8 Venting only Do not recess vent termination into any Wall. This will cause a fire hazardMaximum Three 3 90 Elb ows Horizontal with vertical rise through-the-wall applications Below Grade Installations Vertical through-the-roof applica- tions Flat ceiling installation Installation for vertical termina- tionAbove the first floor, including storage spaces and closets Flex Venting Installation Outside pipeFlex Venting Installation Install gas piping to fireplace location Check gas typeNatural Gas Propane/LPCheck GAS Pressure and Electrical Installation Millivolt Electrical WiringDo not use open flame to check for gas LeaksElectrical installation millivolt Remote Wall mounted Switch for millivolt valves onlyWhat to do if YOU Smell GAS Initial lightingApproved leak testing method Never check for gas leakWith open flame Main burner switch Lighting the burnerPilot position Label all wires before disconnecting when Servicing controls. Wiring errors can causeDo not use open flame to check for gas leaks Signature Command Electrical Installation Command Center Wall InstallationOptional FAN Blower System AC BoxOperating Instructions Signature Command Switch Box OPERATing InstructionsSignature Command System Operation Instructions Features Command CenterControl Board AC Interface Board OptionalKey Combinations for System Settings Command Center Operations Self Diagnostics ChartFUNCTIONS/OPERATION Canopy Installation Reinstalling clamps, keep fingers clearCanopy & Glass Frame Glass Frame RemovalFloor brick Installation Install logs and rock wool ember material in fireboxLOG Installation LOG Installation All Logs on Burner with Rock Wool Burner, Pilot and Control Compart- ment Pilot FlameBurner Burner FlameVent System Glass DoorLogs Rock woolTroubleshooting Standing Pilot IgnitionTroubleshooting Troubleshooting Signature Command SystemFirebox Components Description Qty HDV500Replacement Parts Standing Pilot Millivolt PartsHDV500NV HDV500PV 5a,b,c 13, 14 HDV500 Logs Accessories / Field Installed Options Replacement Parts Vent Components for 4 X 6B\Vent Components for 5 X HDV Series Direct Vent Gas Fireplace MassachusettsHDV Series Dir ct Vent Gas Fireplace Lifetime Warranty Five Year WarrantyBasic Warranty If Warranty Service is NeededEfficiency Ratings Mhsc

HDV500NV/PV specifications

The Monessen Hearth HDV500NV/PV is a powerful and efficient gas fireplace designed to enhance the warmth and ambiance of any living space. This model is part of Monessen's esteemed lineup of vented gas fireplaces, which are known for their elegant designs and performance. The HDV500NV/PV specifically is designed for those who desire both aesthetic appeal and functional heating.

One of the standout features of the HDV500NV/PV is its versatile installation options. It can be vented vertically or horizontally, providing flexibility for various home layouts. This adaptability makes it an ideal choice for homeowners looking to retrofit an existing space or build a new one. With a powerful input rating of up to 30,000 BTUs, it delivers exceptional heat output and efficiently warms the room, ensuring comfort during colder months.

The fireplace boasts a realistic flame presentation, thanks to its innovative burner technology. The advanced burner system creates flickering flames that mimic traditional wood-burning fireplaces, enhancing the overall aesthetic. Additionally, the HDV500NV/PV is equipped with a ceramic glass front that not only showcases the beautiful flames but also provides a clear view while maintaining safety standards.

For convenience, the HDV500NV/PV features a simple, user-friendly remote control that allows homeowners to adjust the flame height and heat output with ease. This feature adds a layer of comfort, as it eliminates the need to manually operate the fireplace for temperature adjustments. The optional adjustable thermostat enhances this convenience, allowing for automated temperature regulation.

The design of the HDV500NV/PV is equally impressive. Its clean lines and elegant finish make it a striking focal point in any room. Available in various styles and trims, it can seamlessly integrate into various home decors, from modern to traditional.

Safety is also a priority with the HDV500NV/PV. It includes built-in safety features such as a gas shut-off valve and an oxygen depletion sensor, providing peace of mind for users.

In summary, the Monessen Hearth HDV500NV/PV is a versatile, efficient, and aesthetically pleasing gas fireplace that combines advanced technologies with user convenience. Its realistic flame presentation, powerful heating capabilities, and stylish design make it a perfect choice for enhancing any home environment.