Monessen Hearth DBX24C* manual LOG Placement, Proper Installation Sequence DFX24C

Page 24

LOG PLACEMENT

Before you begin — This unit is supplied with a set of three ceramic fiber logs. Do not handle these logs with your bare hands. Always wear gloves to prevent skin irritation from ceramic fibers. After handling logs, wash your hands gently with soap and water to remove any traces of fibers.

WARNING

The positioning of the logs is critical to the safe and clean operation of this heater. Sooting and other problems may result if the logs are not properly and firmly positioned in the appliance. Never add additional logs or embellishments such as pine cones, vermiculite or rock wool to the heater.

 

WARNING

Failure to position the parts in accordance with

 

 

 

 

these diagrams or failure to use only parts

 

 

specifically approved with this heater may result

 

 

in property damage or personal injury.

 

 

 

CAUTION

DO NOT sprinkle volcanic rock on the logs or around the pilot or the main burner. This may cause sooting. Only place volcanic rock on the floor of the fireplace.

During initial operation of the new heater, burning logs will give off a paper burning smell and orange flames will be present. Simply open the windows for a few hours to vent the odor.

PROPER INSTALLATION SEQUENCE (DFX24C)

Left Log

See Figure 33.

#2

1. Install the rear log (#3) on back of burner.

 

2. Install the right log (#1) on burner pins on right side of burner.

3. Install the left log (#2) on burner pins on left side of burner.

Burner Pins

Figure 33 - Proper Sequence of Log Installation

(DFX24C)

Right Log

#1

Rear Log

#3

Burner

Pins

24

33D4047

Image 24 Contents
Installation and Operating Instructions Models DFX24C DBX24C DFX32CRead and Save These Instructions What to do if YOU Smell GASContents Important Safety Information InstallerOwner Important Safety Information Product Features OperationNatural GAS Propane / LPGGetting Started PilotThermal Generator General Installation Information DFX24C/DBX24C DFX32CCodes Adequate Combustion and Ventilation AIR15 1/ 2 x 12 x Installing Optional Firebrick Panels Remove fireplace screen See , page 14 and logsBlack Trim Installation DFX24C/DBX24C Attaching Assembled BlackBlack Trim Installation DFX32C Lining Up Corners of Trim KitInstalling Canopy Removing ScreenSecuring Heater to Floor or Hearth Removing GrateLocation of Fireplace Suggested LocationsMinimum42 Fireplace Framing Or /8Custom Cabinet Connecting the GAS Tee Joint Sediment Trap Pipe Nipple Minimum CapChecking GAS Pressure Manual Control FigureElectrical Wiring MILLI-VOLT Connecting Optional Wall Switch or ThermostatOperate That does not Require 110 VAC toConnecting Remote Receiver Checking System OperationComplete Millivolt System Check LOG Placement Proper Installation Sequence DFX24CProper Installation Sequence DFX32C Proper Installation Sequence DBX24CFlame Appearance Checking the Pilot FlameMILLI-VOLT Control Manual and Thermostat ControlInstalling Rock Wool and Checking Burner Flame CleanPlacing Rock Wool Checking Burner FlameChecking the Burner Flame Operating InstructionsFor Your Safety Read Before Lighting Operating InstructionsWhat to do if YOU Smell GAS Manual Control Lighting Instructions To Turn OFF GAS to HeaterThermostatic Control Lighting Instructions Rotation of Control KnobMILLI-VOLT Control Lighting Instructions PilotCleaning and Servicing Match Lighting InstructionsBlower and Other Optional Equipment Optional EquipmentForced AIR KIT Brass LouversIllustrated Parts Breakdown for Cabinet Accessories Standard FeaturesIllustrated Parts Breakdown DFX24C MILLI-VOLT DFX24C ManualReplacement Parts List LOG SETParts AVAILABLE, not Shown DFX32C MILLI-VOLT DFX32C Manual 33D5511 DBX24C T-STAT DBX24C T-STAT DescriptionNatural Propane AVAILABLE, not ShownTroubleshooting Observed Problem Possible Cause RemedyTroubleshooting Lifetime Warranty Five Year WarrantyBasic Warranty