Monessen Hearth DBX24C* manual General Installation Information, DFX24C/DBX24C DFX32C

Page 8

GENERAL INSTALLATION INFORMATION

In planning the installation for the fireplace it is necessary to determine where the unit is to be installed and whether optional accessories are desired. Gas supply piping should also be planned. The following steps represent the normal sequence of installation. Each installation is unique, however, and might require a different sequence.

1.Position fireplace in desired location. See the Location of Fireplace and Clearances and Height Requirements, and Firebox Framing sections found in this manual.

Note: Be sure all packing material has been removed from underside the unit.

2.Install canopy and logs per instructions found in this manual. The canopy MUST be installed for safe operation of the unit.

3.Field wire main power supply to units with fan kit. See the Electrical Section found in this manual. (Electrical connec- tions should only be performed by an experienced, licensed certified tradesman).

4.Install optional ON/OFF kit on units with millivolt control. See installation instruc- tions included with the kit and also See the Electrical Wiring section found in this manual.

5.Plumb gas line. See the Connecting the Gas section found in this manual. (Gas connections should only be performed by an experienced, licensed/certified tradesman).

6.Complete finish wall material and/or surround.

 

A

 

B

C

D

 

E

F

 

G

I

 

H

J

L

 

 

K

 

DFX24C/DBX24C

DFX32C

A

14

213/4

B

131/8

171/2

C

117/8

133/8

D

9

105/8

E

21

27

F

47/8

5

G

17

201/4

H

1

15/8

I

221/2

283/4

J

1

15/8

K

241/2

32

L

45/8

43/4

M

101/2

12

N

261/2

30

M

N

Figure 2 - Firebox Dimensions with Screen and Log Sets Removed

8

33D4047

Image 8 Contents
Installation and Operating Instructions Models DFX24C DBX24C DFX32CRead and Save These Instructions What to do if YOU Smell GASContents Owner Important Safety InformationInstaller Important Safety Information Product Features OperationNatural GAS Propane / LPGThermal Generator Getting StartedPilot General Installation Information DFX24C/DBX24C DFX32CCodes Adequate Combustion and Ventilation AIR15 1/ 2 x 12 x Installing Optional Firebrick Panels Remove fireplace screen See , page 14 and logsBlack Trim Installation DFX24C/DBX24C Attaching Assembled BlackBlack Trim Installation DFX32C Lining Up Corners of Trim KitInstalling Canopy Removing ScreenSecuring Heater to Floor or Hearth Removing GrateLocation of Fireplace Suggested LocationsMinimum42 Fireplace Framing Or /8Custom Cabinet Connecting the GAS Tee Joint Sediment Trap Pipe Nipple Minimum CapChecking GAS Pressure Manual Control FigureElectrical Wiring MILLI-VOLT Connecting Optional Wall Switch or ThermostatOperate That does not Require 110 VAC toComplete Millivolt System Check Connecting Remote ReceiverChecking System Operation LOG Placement Proper Installation Sequence DFX24CProper Installation Sequence DFX32C Proper Installation Sequence DBX24CFlame Appearance Checking the Pilot FlameMILLI-VOLT Control Manual and Thermostat ControlInstalling Rock Wool and Checking Burner Flame CleanPlacing Rock Wool Checking Burner FlameChecking the Burner Flame Operating InstructionsWhat to do if YOU Smell GAS For Your Safety Read Before LightingOperating Instructions Manual Control Lighting Instructions To Turn OFF GAS to HeaterThermostatic Control Lighting Instructions Rotation of Control KnobMILLI-VOLT Control Lighting Instructions PilotCleaning and Servicing Match Lighting InstructionsBlower and Other Optional Equipment Optional EquipmentForced AIR KIT Brass LouversIllustrated Parts Breakdown for Cabinet Accessories Standard FeaturesIllustrated Parts Breakdown DFX24C MILLI-VOLT DFX24C ManualParts AVAILABLE, not Shown Replacement Parts ListLOG SET DFX32C MILLI-VOLT DFX32C Manual 33D5511 DBX24C T-STAT DBX24C T-STAT DescriptionNatural Propane AVAILABLE, not ShownTroubleshooting Observed Problem Possible Cause RemedyTroubleshooting Basic Warranty Lifetime WarrantyFive Year Warranty