Monessen Hearth DBX24C* manual Black Trim Installation DFX32C, Lining Up Corners of Trim Kit

Page 13

GENERAL INSTALLATION INFORMATION

Top Trim Piece

45°-angled

Corners

Back of Trim

Assembly

Side Trim Pieces

Figure 9 - Lining Up Corners of Trim Kit

Outside Corner Slot

90°-angled

Bracket

90°-angled Shim Outside

Corner Slot

Figure 10 - Securing Corners Together

Bracket

Screws

No Spaces

where

Corners Join

Figure 11 - Making Sure Corners Are Flush

Assembled Trim

Trim Flushed

with Front of

Fireplace

Figure 12 - Sliding Assembled Trim Over the Top

of the Heater

BLACK TRIM INSTALLATION (DFX32C)

1.Remove trim from protective packaging. Be careful not to scratch the trim. Remove two (2) 90°-angled mounting brackets and two (2) 90°-angled shims.

2.Lay trim face down on the floor. Line up the 45°-angled corners of the top trim with the 45°-angled corners of the side trims.

Note: Both ends of the top piece of trim are mitered. See Figure 9.

3.Slide one (1) 90°-angled bracket (with attached screws) and one (1) 90°-angled shim in the outside corner slot where the top and side trims meet. See Figure 10.

4.Hold the corners together securely. Tighten screws on bracket with flat head screwdriver. Make sure the corners are flush and there are no spaces. Do not over tighten screws. See Figure 11.

5.Repeat for other side trim.

6.Slide assembled trim over the top and down the sides of the fireplace. Flush trim with front of fireplace as shown in Figure 12.

7.Align holes in assembled trim with holes in side of fire- place. Using a Phillips screwdriver, attach trim with four

(4)screws provided — two for each side of fireplace. Tighten snuggly. See Figure 13.

Screws

Screw

Holes

Screw

Figure 13 - Securing Trim to Heater with Four (4)

Screws Provided

33D4047

13

Image 13 Contents
Models DFX24C DBX24C DFX32C Installation and Operating InstructionsRead and Save These Instructions What to do if YOU Smell GASContents Installer Important Safety InformationOwner Important Safety Information Operation Product FeaturesPropane / LPG Natural GASPilot Getting StartedThermal Generator DFX24C/DBX24C DFX32C General Installation Information Adequate Combustion and Ventilation AIR Codes15 1/ 2 x 12 x Remove fireplace screen See , page 14 and logs Installing Optional Firebrick PanelsAttaching Assembled Black Black Trim Installation DFX24C/DBX24CLining Up Corners of Trim Kit Black Trim Installation DFX32CRemoving Screen Installing CanopyRemoving Grate Securing Heater to Floor or HearthSuggested Locations Location of FireplaceMinimum42 Or /8 Fireplace FramingCustom Cabinet Tee Joint Sediment Trap Pipe Nipple Minimum Cap Connecting the GASManual Control Figure Checking GAS PressureConnecting Optional Wall Switch or Thermostat Electrical Wiring MILLI-VOLTOperate That does not Require 110 VAC toChecking System Operation Connecting Remote ReceiverComplete Millivolt System Check Proper Installation Sequence DFX24C LOG PlacementProper Installation Sequence DBX24C Proper Installation Sequence DFX32CChecking the Pilot Flame Flame AppearanceMILLI-VOLT Control Manual and Thermostat ControlClean Installing Rock Wool and Checking Burner FlamePlacing Rock Wool Checking Burner FlameOperating Instructions Checking the Burner FlameOperating Instructions For Your Safety Read Before LightingWhat to do if YOU Smell GAS To Turn OFF GAS to Heater Manual Control Lighting InstructionsRotation of Control Knob Thermostatic Control Lighting InstructionsPilot MILLI-VOLT Control Lighting InstructionsMatch Lighting Instructions Cleaning and ServicingOptional Equipment Blower and Other Optional EquipmentForced AIR KIT Brass LouversStandard Features Illustrated Parts Breakdown for Cabinet AccessoriesDFX24C MILLI-VOLT DFX24C Manual Illustrated Parts BreakdownLOG SET Replacement Parts ListParts AVAILABLE, not Shown DFX32C MILLI-VOLT DFX32C Manual 33D5511 DBX24C T-STAT Description DBX24C T-STATNatural Propane AVAILABLE, not ShownObserved Problem Possible Cause Remedy TroubleshootingTroubleshooting Five Year Warranty Lifetime WarrantyBasic Warranty