INSTALLING ROCK WOOL AND CHECKING BURNER FLAME
PLACING ROCK WOOL
DFX24C AND DFX32C MODELS
After installing logs, pull apart
| WARNING | • Use only rock wool provided with log set. |
| • Do not add additional rock wool. | |
|
| |
|
| • Place rock wool on burner ports only. |
|
| • Keep air gap between rear log and burner |
|
| CLEAN. |
|
|
|
Dime Size
Rock Wool
Figure 40 - Rockwool Installation
(DFX24C and DFX32C)
CHECKING BURNER FLAME
DBX24C MODEL
In normal operation at full rate after 15 minutes, the following flame appearances should be observed:
The flames inside the
DFX24C AND DFX32C MODELS
In normal operation at full rate after 15 minutes, the following flame appearances should be observed:
Burner will have a random pattern of yellow flames. See Figures 42 and 43. There should be glowing embers in front of burner.
NOTE: The front flames and embers will be an opaque orange color during the burn off time.
Log
Figure 41 - Correct Appearance of Flames
(DBX24C)
Figure 42 - Correct Appearance of Flames | Figure 43 - Correct Appearance of Flames |
(DFX24C) | (DFX32C) |
33D4047 | 27 |