FACE PLATE, UPPER GRILL, KEYSTONE & DOOR INSTALLATION

1Remove the facing template held in place with the 12 screws shown. Dis- card the screws and template.

2Mount the keystone and upper grill to the face- plate, as shown, using the 4 nuts supplied.

Remove the backing and place logo onto the bottom left corner of the faceplate.

Ensure that the pressure switch actuating arm and air control rod, protrude through the faceplate when in- stalled.

Remember to record your serial # in the manual for future quick reference.

3 Secure the faceplate to the unit, using the 12

screws supplied.

Start all 12 screws, then tighten evenly.

Right Door Handle

4(operating)

-Insert the door rod through the round hole of the latch ensuring the flat edge of the “D” shaped hole points towards the

hinges.

-Slide the end of the door rod through the bushing at the top of the door as shown.

-Insert the handle shaft through the door and the latch.

-Secure with 2 flat wash- ers and a nut.

See Note #1

- Feed the handle through the handle spacer and into t h e handle shaft.

Left Door Handle

(fixed)

-Insert the handle shaft through the door.

-Secure with a lock washer, 2 flat washers and a nut.

-Feed the handle through the handle spacer and into the handle shaft.

See Note #2

Note #1: You may need to move washers to the other side of the latch to obtain sufficient door seal.

Note #2: The final angle of the left door handle should mirror the right door handle in the closed position. Tighten the nut to secure the left handle at the desired angle.

W415-0594 / A / 02.15.07

Image 13
Contents W415-0442 / C W415-0594 / a W415-0594 / a Table of Contents Napoleon Wood Fireplace Presidents Lifetime Limited Warranty General Instructions IntroductionHeating Specifications General Information FeaturesElectrical Specifications Packing ListHI-EFFICIENCY Heating Installation / FramingCeiling From the base of the unit Enclosure Location and ClearancesWhen Using AN AIR Cooled Chimney When Using a Solid Pack Chimney Mantle Clearances Outside Combustion AIR Vertical Horizontal Rise is Run may be Between Included with the fireplace areSee hearth examples Hearth ExtensionHearth Examples See Note #1 Face PLATE, Upper GRILL, Keystone & Door InstallationSee Note #2 Chimney Installation Straightup Elbows Adding Chimney SectionsInstalling Flashing and Storm Collar Offset Chimney InstallationIf the Chimney Connectionto a Masonry ChimneyFinishing AIR Cooled Chimney InstallationAttaching the Handle AIR Contol Knob Wolf SteelFor complete instructions, see Blower kit Optional NZ64 Blower KIT InstallationNZ64 Blower Installation Liner supplied stretches to a maximum of 10’ Electrical ConnectionNSK Optional Screen KIT NZ64 Blower ReplacementOperating Sounds and Smells Operating InstructionsStarting a Fire Draft ControlW415-0594 / a Fuel Loading and Burn Cycle RE-LOADING the Fireplace ASH Removal ProceduresFlash Fires Overnight BurnGlass & Gasket Replacement MaintenanceTips for Burning RUN-AWAY or Chimney FireCreosoteformation Andremoval Selecting WoodFireplace and Accessory Replacement Parts ReplacementsAccessories W415-0594 / a Symptom Problem Test Solution Trouble Shooting GuideRating Plate