STRAIGHTUP

2 ELBOWS

4 ELBOWS

No Off-Set. Minimum overall chim- ney height is 15 feet.

Single off-set with two 15°, 30° or 45° elbows. Minimum overall chimney height is 15 feet.

Double off-set with four 15°, 30° or 45° elbows. Minimum overall chim- ney height is 15 feet.

*The first flue offset closest to the top of the unit must be a minimum distance of 12 inches from the top of the fireplace.

1.Move the fireplace into position. Try to center the ex- haust flue of the fireplace, midpoint between two joists to prevent having to cut them. Use a plumb bob to line up the centre.

2.Cut and frame an opening in the ceiling to provide a minimum clearance of 2" between the outside of the chim- ney and any combustible material. DO NOT FILL THIS SPACE WITH ANY TYPE OF MATERIAL! Nail headers between the joists for extra support. Firestop spacers must be placed on each framed opening in any floor or ceiling that the chimney passes through.

3.Hold a plumb bob from the underside of the roof to determine where the opening in the roof should be. Cut and frame the roof opening maintaining proper 2" clear- ances.

NOTE: 30° or 45° offsets may be installed back to back.

ADDING CHIMNEY SECTIONS

Add chimney sections, securely, to the required height. Use a rafter radiation shield whenever the chimney system is enclosed within an attic area.

-Chimney must extend 3' above the roof.

-Chimney must extend 2' above any portion of the roof within 10' of the chimney.

W415-0594 / A / 02.15.07

Image 15
Contents W415-0442 / C W415-0594 / a W415-0594 / a Table of Contents Napoleon Wood Fireplace Presidents Lifetime Limited Warranty General Instructions IntroductionPacking List General Information FeaturesHeating Specifications Electrical SpecificationsHI-EFFICIENCY Heating Installation / FramingCeiling From the base of the unit Enclosure Location and ClearancesWhen Using AN AIR Cooled Chimney When Using a Solid Pack ChimneyIncluded with the fireplace are Outside Combustion AIRMantle Clearances Vertical Horizontal Rise is Run may be BetweenSee hearth examples Hearth Extension Hearth Examples Face PLATE, Upper GRILL, Keystone & Door Installation See Note #1See Note #2 Chimney Installation Straightup Elbows Adding Chimney SectionsInstalling Flashing and Storm Collar Offset Chimney InstallationIf the Chimney Connectionto a Masonry ChimneyWolf Steel AIR Cooled Chimney InstallationFinishing Attaching the Handle AIR Contol KnobFor complete instructions, see Blower kit Optional NZ64 Blower KIT InstallationNZ64 Blower Installation Liner supplied stretches to a maximum of 10’ Electrical ConnectionNSK Optional Screen KIT NZ64 Blower ReplacementDraft Control Operating InstructionsOperating Sounds and Smells Starting a FireW415-0594 / a Fuel Loading and Burn Cycle Overnight Burn ASH Removal ProceduresRE-LOADING the Fireplace Flash FiresRUN-AWAY or Chimney Fire MaintenanceGlass & Gasket Replacement Tips for BurningCreosoteformation Andremoval Selecting WoodReplacements Fireplace and Accessory Replacement PartsAccessories W415-0594 / a Symptom Problem Test Solution Trouble Shooting GuideRating Plate