Napoleon Fireplaces NZ6000 manual Connectionto a Masonry Chimney, If the Chimney

Page 17

17

CONNECTIONTO A MASONRY CHIMNEY

The Napoleon Model NZ6000 may be connected to either a lined or unlined masonry chimney.

IF THE CHIMNEY

IS LINED, the flues

must be made of vitrified clay and be in sizes of 8" square or 8" round (inside diameters) or 8"x12" with a minimum height of 15 feet above the fireplace. Eight inch round flues are recommended. Installation must conform to both national and local code requirements.

IF THE CHIMNEY IS UNLINED, a stainless steel liner

listed to either Standard ULC-S640M in Canada or UL- 1777 in the USA: Liners for New Masonry Chimneys, may be used to connect the fireplace to the chimney. The liner must be continuous from the fireplace to the chimney cap and be installed only per manufacturers instructions. In both cases, the chimney structure must be supported by angle iron anchored into the masonry walls. The allow- able masonry used in chimney construction is 3-1/2" brick, solidly mortared and fully encasing the flue. Ensure there are no leaks.

In no case is the masonry enclosure to be supported by the NZ6000 fireplace. Allow a 1" (one inch) air cavity for expansion.

ANCHOR PLATE

FIREPLACE TOP

FLUE TILE SUPPORT FOR A MASONRY FIREPLACE

FIREPLACE TOP

For a masonry fireplace use a flue tile support. For a pre- fabricated chimney use an anchor plate.

W415-0594 / A / 02.15.07

Image 17
Contents W415-0442 / C W415-0594 / a W415-0594 / a Table of Contents Napoleon Wood Fireplace Presidents Lifetime Limited Warranty General Instructions IntroductionHeating Specifications General Information FeaturesElectrical Specifications Packing ListHI-EFFICIENCY Heating Installation / FramingCeiling From the base of the unit Enclosure Location and ClearancesWhen Using AN AIR Cooled Chimney When Using a Solid Pack ChimneyMantle Clearances Outside Combustion AIRVertical Horizontal Rise is Run may be Between Included with the fireplace areSee hearth examples Hearth ExtensionHearth Examples See Note #2 Face PLATE, Upper GRILL, Keystone & Door InstallationSee Note #1 Chimney Installation Straightup Elbows Adding Chimney SectionsInstalling Flashing and Storm Collar Offset Chimney InstallationIf the Chimney Connectionto a Masonry ChimneyFinishing AIR Cooled Chimney InstallationAttaching the Handle AIR Contol Knob Wolf SteelFor complete instructions, see Blower kit Optional NZ64 Blower KIT InstallationNZ64 Blower Installation Liner supplied stretches to a maximum of 10’ Electrical ConnectionNSK Optional Screen KIT NZ64 Blower ReplacementOperating Sounds and Smells Operating InstructionsStarting a Fire Draft ControlW415-0594 / a Fuel Loading and Burn Cycle RE-LOADING the Fireplace ASH Removal ProceduresFlash Fires Overnight BurnGlass & Gasket Replacement MaintenanceTips for Burning RUN-AWAY or Chimney FireCreosoteformation Andremoval Selecting WoodAccessories ReplacementsFireplace and Accessory Replacement Parts W415-0594 / a Symptom Problem Test Solution Trouble Shooting GuideRating Plate