Napoleon Fireplaces GE38PT-M, GE38NT-M manual Ember BED Bulb Replacement, Fireplace Operation

Page 20

20

EMBER BED BULB REPLACEMENT

FIGURE 47

1.Remove the lower control panel by removing the 8 se- curing screws.

FIGURE 48

LIGHT SOCKET

2.Hold the lower portion of the light socket and turn clockwise to remove.

3.Pull the bulb straight out of the socket and replace the bulb being careful not to touch the quartz portion with your fingers.

4.To put back together, reinstall the control panel removed in step 1.

OPERATION

FIREPLACE OPERATION

To operate the gas features, the pilot needs to be running and the gas valve turned to the on position.

You can run the fireplace on manual or remote.

When operating the main burner on manual, the fireplace will operate on low input only.

FIGURE 49

GAS

Turn the respective main power switches to manual to operate either the gas or the electric features of the fire- place without the remote or thermostat.

Turn both the main power switches to remote to operate either the gas or the electric features of the fireplace with the remote or thermostat.

Turn both the main power switches to the off position to disable either the gas or the electric features of the fireplace.

In order to save the battery life on the remote, it is recommended that when operating the electric fireplace for an extended period of time, to operate with the electric power switch in the manual position.

FIGURE 50

HAND HELD REMOTE OPERATION

1.Turns electric flame on/off.

2.Turns gas flame on/off.

3.Activates gas flame adjustment.

4.Activates fan adjustment.

5.Adjusts options #3 & #4 up.

6.Sets the timer.

7.Adjusts options #3 & #4 down.

8.Sets the time.

W415-0429 / C / 11.04.05

Image 20
Contents Direct Vent Millivolt System Table of Contents Napoleon GAS Fireplace Presidents Lifetime Limited Warranty Care of GLASS, and Plated Parts General InstructionsGeneral Information Venting Venting LengthsAIR Terminal Installations Typical Vent Installations Special Vent InstallationsVenting Application Flow Chart Horizontal Termination Vertical TerminationElbow Vent Length Values TOP Exit / Horizontal TerminationDefinitions 90 H2 H3 TOP Exit Vertical Termination 90 V1 H3 H1 290 H Vertical Installation Installation Wall and Ceiling ProtectionHorizontal Installation Using Flexible Vent Components Horizontal AIR Terminal InstallationUsing Rigid Vent Components Fireplace Vent ConnectionVertical Venting Installation GAS InstallationNailing Tabs Mobile Home InstallationFraming Finishing Door Removal & Installation Gvfl Louvre Installation L38 Louvre Installation LOG Placement Blower Replacement Flame Effect Bulb ReplacementEmber BED Bulb Replacement OperationFireplace Operation Hand Held Remote OperationMaintenance Operating InstructionsElectrical Connection Hard Wiring ConnectionElectrical Diagram Legend Venturi Adjustment AdjustmentsPilot Burner Adjustment Replacements 3427 Trouble Shooting Guide Symptom Problem Test SolutionElectric Trouble Shooting Do not Clean Glass When HOTWolf Steel Fireplace Service History