OPERATING INSTRUCTIONS

When lit for the first time, the fireplace will emit a slight odour for a few hours. This is a normal temporary condi- tion caused by the curing of the logs and the "burn-in" of internal paints and lubricants used in the manufacturing process and will not occur again.

FOR YOUR SAFETY READ BEFORE LIGHTING:

A. This fireplace is equipped with a pilot which must be lit by hand while following these instructions exactly.

B. Before operating smell all around the fireplace area for gas and next to the floor because some gas is heavier than air and will settle on the floor

C. Use only your hand to turn the gas control knob. Never use tools. If the knob will not turn by hand, do not try to repair it. Call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D. Do not use this fireplace if any part has been under water. Immediately call a qualified service technician to inspect the fireplace and replace any part of the control system and any gas control which has been under water.

21

After extended periods of non-operation such as following a vacation or a warm weather season, the fireplace may emit a slight odour for a few hours. This is caused by dust particles in the heat exchanger burning off. In both cases, open a window to sufficiently ventilate the room.

Purge the gas line with the glass door open. Assure that a continuous gas flow is at the burner before closing the door.

WHAT TO DO IF YOU SMELL GAS

Turn off all gas to the fireplace.

 

LO

T

 

 

 

I

Open windows.

FIGURE 51

P

 

 

F

 

O

 

 

 

 

N

Do not try to light any appliance.

F

 

O

 

 

 

 

 

 

 

Do not touch any electric switch; do

 

 

 

 

not use any phone in your building.

GAS KNOB

Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire de- partment.

FIGURE 52

LIGHTING INSTRUCTIONS

WARNING: The gas valve has an interlock device which will not allow the pilot burner to be lit until the thermocou- ple has cooled. Allow approximately 60 seconds for the thermocouple to cool.

When lighting and re-lighting, the gas knob cannot be turned from pilot to off unless the knob is depressed slightly.

1.Stop! Read the above safety information on this label.

2.Turn off all electric power to the fireplace.

3.Turn the gas knob clockwise to off.

4.Wait five (5) minutes to clear out any gas. If you smell gas including near the floor. Stop! Follow "B" in the above safety

information on this label. If you don't smell gas go the next step.

5.Turn gas knob counter-clockwise to pilot.

6.Depress slightly and hold gas knob while lighting the pilot with the push button ignitor. Keep knob depressed for one minute, then release. If pilot does not continue to burn, repeat steps 3 through 5.

7.With pilot lit, depress and turn gas knob counter-clock-

wise to on.

8.If equipped with remote on-off switch/thermostat, main burner may not come on when you turn valve to on. Remote switch must be in the on position to ignite burner.

9.Turn on all electric power to the fireplace.

TO TURN OFF GAS

1. Turn off all electric power to the fireplace if service is

2. Push in gas control knob slightly and turn clockwise

to be performed.

to off. Do not force.

MAINTENANCE

Turn off the gas and electrical power before servicing the fireplace.

CAUTION: Label all wires prior to disconnection when serv- icing controls. Wiring errors can cause improper and dan- gerous operation. Verify proper operation after servicing. This fireplace and its venting system should be inspected before use and at least annually by a qualified service per- son. The fireplace area must be kept clear and free of com- bustible materials, gasoline or other flammable vapours and liquids. The flow of combustion and ventilation air must not be obstructed.

1.In order to properly clean the burner and pilot assembly, remove the logs to expose both assemblies.

2.Keep the control compartment, logs, burner, air shutter opening and the area surrounding the logs clean by vacu- uming or brushing, at least once a year.

3.Check to see that all burner ports are burning. Clean out any of the ports which may not be burning or are not burn- ing properly.

4.Check to see that the pilot flame is large enough to engulf the thermocouple and thermopile and reaches to- ward the burner with the third jet.

5.Replace the cleaned logs.

6.Check to see that the main burner ignites completely on all openings when the gas knob for the burner is turned on. A 5 to

10second total light-up period is satisfactory. If ignition takes longer, consult your Continental dealer / distributor.

7.Check that the gasketing on the sides, top and bottom of the door is not broken or missing. Replace if necessary.

W415-0429 / C / 11.04.05

Image 21
Contents Direct Vent Millivolt System Table of Contents Napoleon GAS Fireplace Presidents Lifetime Limited Warranty General Instructions General InformationCare of GLASS, and Plated Parts Venting Lengths VentingAIR Terminal Installations Special Vent Installations Typical Vent InstallationsVenting Application Flow Chart Horizontal Termination Vertical TerminationTOP Exit / Horizontal Termination DefinitionsElbow Vent Length Values 90 H2 H3 90 V1 H3 H1 2 TOP Exit Vertical Termination90 H Installation Wall and Ceiling Protection Horizontal InstallationVertical Installation Horizontal AIR Terminal Installation Using Flexible Vent ComponentsFireplace Vent Connection Using Rigid Vent ComponentsGAS Installation Vertical Venting InstallationMobile Home Installation FramingNailing Tabs Door Removal & Installation Gvfl Louvre Installation L38 Louvre InstallationFinishing LOG Placement Flame Effect Bulb Replacement Blower ReplacementOperation Ember BED Bulb ReplacementFireplace Operation Hand Held Remote OperationOperating Instructions MaintenanceHard Wiring Connection Electrical Diagram LegendElectrical Connection Adjustments Pilot Burner AdjustmentVenturi Adjustment Replacements 3427 Symptom Problem Test Solution Trouble Shooting GuideDo not Clean Glass When HOT Electric Trouble ShootingWolf Steel Fireplace Service History

GE38PT-M, GE38NT-M specifications

The Napoleon Fireplaces GE38PT-M and GE38NT-M are stunning additions to the world of modern heating solutions, designed to combine aesthetics and functionality seamlessly. These fireplaces are ideal for homeowners looking for an efficient, stylish way to enhance their living spaces while providing the warmth and comfort that only a genuine fireplace can offer.

One of the standout features of the GE38PT-M and GE38NT-M is their innovative design, which emphasizes versatility and ease of installation. Both models come in a stunning panorama format, allowing for a wide viewing area that showcases the mesmerizing flames, creating a captivating focal point in any room. The clean and contemporary lines of these fireplaces make them a perfect fit for both traditional and modern interiors.

A key technology incorporated into these models is the advanced catalytic combustion system. This system not only enhances the efficiency of the fireplace but also significantly reduces emissions, making it an eco-friendly choice. The GE38PT-M is designed for propane, while the GE38NT-M operates on natural gas. Both options provide maximum efficiency with a minimum environmental footprint.

The fireplaces are equipped with intuitive control options, allowing users to easily adjust the flame height and heat output to achieve the desired ambiance and comfort level. With a built-in electronic ignition system and a convenient remote control, operating the GE38PT-M and GE38NT-M is a breeze, allowing you to set the perfect atmosphere at the touch of a button.

Additionally, these models include an array of customizable features. Homeowners can choose from a variety of decorative media, including glass beads and logs, allowing for personalization that enhances the visual appeal of the flames. The ambient lighting options also allow users to create different atmospheres, making these fireplaces a versatile choice for any occasion.

Safety is paramount in the design of the GE38PT-M and GE38NT-M. These models are equipped with a protective screen and a safety shut-off feature, ensuring peace of mind for families and pets. With their striking aesthetics, innovative technology, and safety features, the Napoleon Fireplaces GE38PT-M and GE38NT-M stand out as an exceptional choice for anyone looking to elevate their home's heating experience.