ELECTRICAL CONNECTION

This fireplace requires 6 amps, 120 volt and a 60 hz grounded circuit.

Do NOT use the fireplace if any part has been under water.

Call a qualified service technician IMMEDIATELY to have the fireplace inspected for damage to the electrical cir- cuit.

HARD WIRING CONNECTION

It is necessary to hard wire this fireplace.

Permanently framing the fireplace with an enclosure, re- quires the fireplace to be hardwired.

This fireplace must be electrically connected and grounded in accordance with local codes. In the absence of local codes, use the current CSA C22.1 CANADIAN ELECTRI- CAL CODE in Canada or the ANSI/NFPA 70-1996 NATIONAL ELECTRICAL CODE in the United States.

The plastic coating of the two electrical inlet lines are marked "H" for hot and "C" for common.

ELECTRICAL DIAGRAM LEGEND

# Part #

Description

1 . W660 - 0029 Controller

2.W707-0003 Transformer

3. W660-0034

Rocker Switch

4.W062-0005 Blower

5. W750-0117

Light Harness

6.W387-0004 5 Watt Quartz Light

7. W435-0004

12 Volt Motor

8.W350-0126 Receptical (Electrical Box)

9.W387-0003 75 Watt Quartz Bulbs

10.W725-0035 Natural Gas Valve

 

W725-0034

Propane Valve

11.

W750-0122

1 pcs

12.

W750-0123

1 pcs

13.

W750-0124

1 pcs

14.

W750-0134

1 pcs

15.

W175-0010

Wire Nut

16.W750-0133 Line In Wire Harness (common)

17.W750-0133 Line In Wire Harness (hot)

18. W750-0135

1 pcs

19 . W750 - 0136

1 pcs

Electric Diagram

FIGURE 53

W415-0429 / C / 11.04.05

Image 22
Contents Direct Vent Millivolt System Table of Contents Napoleon GAS Fireplace Presidents Lifetime Limited Warranty General Information General InstructionsCare of GLASS, and Plated Parts Venting Venting LengthsAIR Terminal Installations Venting Application Flow Chart Typical Vent InstallationsSpecial Vent Installations Horizontal Termination Vertical TerminationDefinitions TOP Exit / Horizontal TerminationElbow Vent Length Values 90 H2 H3 TOP Exit Vertical Termination 90 V1 H3 H1 290 H Horizontal Installation Installation Wall and Ceiling ProtectionVertical Installation Using Flexible Vent Components Horizontal AIR Terminal InstallationUsing Rigid Vent Components Fireplace Vent ConnectionVertical Venting Installation GAS InstallationFraming Mobile Home InstallationNailing Tabs Gvfl Louvre Installation L38 Louvre Installation Door Removal & InstallationFinishing LOG Placement Blower Replacement Flame Effect Bulb ReplacementFireplace Operation Ember BED Bulb ReplacementOperation Hand Held Remote OperationMaintenance Operating InstructionsElectrical Diagram Legend Hard Wiring ConnectionElectrical Connection Pilot Burner Adjustment AdjustmentsVenturi Adjustment Replacements 3427 Trouble Shooting Guide Symptom Problem Test SolutionElectric Trouble Shooting Do not Clean Glass When HOTWolf Steel Fireplace Service History