TOP EXIT VERTICAL TERMINATION

when (Ht) < (Vt)

Example 4:

 

Simple venting configurations

 

 

FIGURE 10

FIGURE 11

V2

 

90°

 

 

90° V1 H3 90°

H

H1 2 90°

See graph to determine the required vertical rise VT for the required horizontal run HT.

REQUIRED

VERTICAL RISE

IN FEET

VT

HORIZONTAL VENT RUN PLUS OFFSET IN FEET HT

The shaded area within the lines represents acceptable values for HT and VT .

For vent configurations requiring elbows, the following for- mulas apply:

Formula 1: HT < VT

Formula 2: HT + VT < 40 feet

V1

=5 ft

V2

=10 ft

VT

= V1 + V2 = 5 + 10 = 15 ft

H1

=1 ft

H2

=3 ft

H3

=2.5 ft

HR

= H1 + H2 + H3 = 1 + 3 + 2.5 = 6.5 ft

HO

= .03(four 90° elbows - 90°)

 

= .03(90 + 90 + 90 + 90 - 90) = 8.1 ft

HT

=HR + HO = 6.5 + 8.1 = 14.6 ft

HT + VT = 14.6 + 15 = 29.6 ft

Formula 1: HT < VT 14.6 < 15

Formula 2: HT + VT < 40 feet

29.6 < 40

Since both formulas are met, this vent configuration is ac- ceptable.

W415-0429 / C / 11.04.05

Image 10
Contents Direct Vent Millivolt System Table of Contents Napoleon GAS Fireplace Presidents Lifetime Limited Warranty General Information General InstructionsCare of GLASS, and Plated Parts Venting Venting LengthsAIR Terminal Installations Venting Application Flow Chart Typical Vent Installations Special Vent Installations Horizontal Termination Vertical TerminationDefinitions TOP Exit / Horizontal TerminationElbow Vent Length Values 90 H2 H3 TOP Exit Vertical Termination 90 V1 H3 H1 290 H Horizontal Installation Installation Wall and Ceiling ProtectionVertical Installation Using Flexible Vent Components Horizontal AIR Terminal InstallationUsing Rigid Vent Components Fireplace Vent ConnectionVertical Venting Installation GAS InstallationFraming Mobile Home InstallationNailing Tabs Gvfl Louvre Installation L38 Louvre Installation Door Removal & InstallationFinishing LOG Placement Blower Replacement Flame Effect Bulb ReplacementFireplace Operation Ember BED Bulb ReplacementOperation Hand Held Remote OperationMaintenance Operating InstructionsElectrical Diagram Legend Hard Wiring ConnectionElectrical Connection Pilot Burner Adjustment AdjustmentsVenturi Adjustment Replacements 3427 Trouble Shooting Guide Symptom Problem Test SolutionElectric Trouble Shooting Do not Clean Glass When HOTWolf Steel Fireplace Service History