11

AIR TERMINAL INSTALLATIONS

FIGURE 12

 

INSTALLATIONS

 

 

 

 

 

 

CANADIAN

U.S.A.

 

 

 

 

 

A

12 INCHES

12 INCHES

Clearance above grade, veranda porch, deck or balcony.

 

 

 

 

B

12 INCHES

9 INCHES

Clearance to windows or doors that open.

 

 

 

 

C

12 INCHES*

12 INCHES*

Clearance to permanently closed windows.

 

 

 

 

D

18 INCHES**

18 INCHES**

Vertical clearance to ventilated soffit located above the terminal within

a horizontal distance of 2 feet from the centerline of the terminal.

 

 

 

 

E

12 INCHES**

12 INCHES**

Clearance to unventilated soffit.

 

 

 

 

F

0 INCHES

0 INCHES

Clearance to an outside corner wall.

 

 

 

 

 

0 INCHES***

0 INCHES***

Clearance to an inside non-combustible corner wall or protruding

 

non-combustible obstructions (chimney, etc.).

 

 

 

G

 

 

Clearance to an inside combustible corner wall or protruding com-

 

2 INCHES***

2 INCHES***

 

bustible obstructions ( vent chase, etc.).

 

 

 

 

 

 

 

H

3 FEET

3 FEET****

Clearance to each side of the centerline extended above the meter

/ regulator assembly to a maximum vertical distance of 15ft.

 

 

 

 

 

 

 

I

3 FEET

3 FEET****

Clearance to a service regulator vent outlet.

J

12 INCHES

9 INCHES

Clearance to a non-mechanical air supply inlet to the building or a

combustion air inlet to any other appliance.

 

 

 

 

 

 

 

K

6 FEET

3 FEET†

Clearance to a mechanical air supply inlet.

 

 

 

 

L

7 FEET‡

7 FEET****

Clearance above a paved sidewalk or paved driveway located on

public property unless fitted with a heat shield kit GD-301.

 

 

 

 

 

 

 

M

12 INCHES††

12 INCHES****

Clearance under a veranda, porch, deck or balcony.

 

 

 

 

N

16 INCHES

16 INCHES

Clearance above the roof.

 

 

 

 

O

2 FEET†*

2 FEET†*

Clearance from an adjacent wall including neighbouring buildings.

 

 

 

 

 

 

*Recommended to prevent condensation on windows and thermal breakage

**It is recommended to use a heat shield and to maximize the distance to vinyl clad soffits.

***The periscope GD-201 requires a minimum 18 inches clearance from an inside corner.

****This is a recommended distance. For additional requirements check local codes.

Three feet above if within 10 feet horizontally.

A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings.

††Permitted only if the veranda, porch, or deck is fully open on a minimum of two sides beneath the floor.

†* Recommenced to prevent recirculation of exhaust products. For additional requirements check local codes.

W415-0447 / B / 05.24.05

Image 11
Contents W415-0447 / B What to do if YOU Smell GAS Table of Contents Napoleon GAS Fireplace Presidents Lifetime Limited Warranty General Information General InstructionsVenting Lengths & AIR Terminal Locations VentingCare of GLASS, and Plated Parts Elbow Vent Length Values TOP Exit / Horizontal TerminationDefinitions V190 TOP Exit Vertical Termination Formula 1 HT 3VT Formula 2 HT + VT 40 feet Example TOP Vertical TerminationAIR Terminal Installations Vertical Installation Installation Wall and Ceiling ProtectionHorizontal Installation Vertical AIR Terminal Installation Using Flexible Vent ComponentsHorizontal AIR Terminal Installation Fireplace Vent Connection Using Rigid Vent ComponentsExtended Horizontal AIR Terminal Installation Restricting Vertical Vents Vertical Venting Installation GAS InstallationClearance to Combustibles FramingMantle Clearances Hard Wiring ConnectionSchematic Electrical ConnectionLOG Shipping Bracket FinishingCharcoal Embers LOG PlacementBaffle Installation Glowing EmbersLamp Replacement Blower ReplacementRemote Receiver Removal Remote and Valve AccessInner Access Door Control DoorHand Held Remote Operation Operation / MaintenanceFireplace Operation Operating Instructions Venturi Adjustment AdjustmentsMaintenance Pilot Burner AdjustmentReplacements W415-0447 / B Symptom Problem Test Solution Trouble Shooting GuideStanding Main