Decorative brick panels must be installed before the logs.

See installation instructions supplied with the panel kit.

LOG PLACEMENT

PHAZERTM logs, exclusive to Napoleon Fireplaces, provide a unique and realistic glowing effect that is different in every installation. The madison logs are fuel specific. Do not

interchange. Refer to the replacement parts list.

FIGURE 40a-f

1

4

4.Place log #4, with the charred branch pointed inward. Locate the pins into the holes in log#1 and log#2, this will hold the rear log in position.

1.Place the rear log #1 onto the locating studs along the back edge of the PHAZERAMIC™ burner.

2

2.Position log #2 onto the locators on the PHAZERAMIC™ burner.

3

3.Position the slot on the bottom of log #3 onto the bracket shown with the charred face of the log to the front.

Note

 

For propane, remove the

BRACKET

screw from the #3 log support

bracket. Move the bracket to

 

the right most location, then

 

install the log.

 

5

5.Place the end of log #5 on the right end of log #1. The fork in the log should straddle the knot on top of log #2.

GLOWING EMBERS

Glowing embers are NOT recommended. The burner has been designed to achieve maximum glow without embers.

BAFFLE INSTALLATION

Your fireplace has been supplied with the decorative brick panels installed, however, it is necessary to install the fibre baffle, on top of the side and rear panels.

CHARCOAL EMBERS

Charcoal provided could be randomly placed on the fibre hearth on both sides of the burner, and across the front, es- pecially at the hearth joint.

Log colours may vary. During the initial use of the fire- place, the colours will become more uniform as colour pigments burn in during the heat activated curing pro- cess.

Positioning the logs improperly will cause flame impinge- ment and carboning.

Blocked burner ports can cause an incorrect flame pattern, carbon deposits and delayed ignition. PHAZERTM logs glow when exposed to direct flame. Use only certified PHAZERTM logs available from your Napoleon dealer.

W415-0447 / B / 05.24.05

Image 19
Contents W415-0447 / B What to do if YOU Smell GAS Table of Contents Napoleon GAS Fireplace Presidents Lifetime Limited Warranty General Information General InstructionsCare of GLASS, and Plated Parts VentingVenting Lengths & AIR Terminal Locations Definitions TOP Exit / Horizontal TerminationElbow Vent Length Values V190 TOP Exit Vertical Termination Formula 1 HT 3VT Formula 2 HT + VT 40 feet Example TOP Vertical TerminationAIR Terminal Installations Horizontal Installation Installation Wall and Ceiling ProtectionVertical Installation Horizontal AIR Terminal Installation Using Flexible Vent ComponentsVertical AIR Terminal Installation Extended Horizontal AIR Terminal Installation Using Rigid Vent ComponentsFireplace Vent Connection Restricting Vertical Vents Vertical Venting Installation GAS InstallationClearance to Combustibles FramingMantle Clearances Hard Wiring ConnectionSchematic Electrical ConnectionLOG Shipping Bracket FinishingCharcoal Embers LOG PlacementBaffle Installation Glowing EmbersLamp Replacement Blower ReplacementRemote Receiver Removal Remote and Valve AccessInner Access Door Control DoorFireplace Operation Operation / MaintenanceHand Held Remote Operation Operating Instructions Venturi Adjustment AdjustmentsMaintenance Pilot Burner AdjustmentReplacements W415-0447 / B Symptom Problem Test Solution Trouble Shooting GuideStanding Main