SYMPTOM

 

PROBLEM

 

TEST SOLUTION

 

 

 

 

 

 

 

 

 

Pilot burning; no

Themostat or switch is defec-

- connect a jumper wire across the wall switch terminals; if main burner

 

gas to main burner;

tive.

lights, replace switch / thermostat.

 

gas knob is on 'HI';

Wall switch wiring is defec-

-

disconnect switch wires &connect a jumper wire across terminals 1

 

wall switch / ther-

tive.

& 3; if the main burner lights, check the wires for defects and / or re-

 

mostat is on.

 

 

place wires.

 

 

 

 

 

 

Main burner orifice is plugged.

-

remove stoppage in orifice.

 

 

Faulty valve.

-

replace.

 

 

 

 

 

 

Pilot goes out while

Gas piping is undersized.

- turn on all gas appliances and see if pilot flame flutters, diminishes or

 

standing; Main

 

 

extinguishes, especially when main burner ignites. Monitor appliance

 

burner is in 'OFF'

 

 

supply working pressure.

 

position.

 

 

-

check if supply piping size is to code. Correct all undersized piping.

 

 

 

 

 

 

 

Pilot will not light.

No spark at pilot burner

-

check if pilot can be lit by a match

 

 

 

 

-

check that the wire is connected to the push button ignitor.

 

 

 

 

-

check if the push button ignitor needs tightening.

 

 

 

 

-

replace the wire if the wire insulation is broken or frayed.

 

 

 

 

-

replace the electrode if the ceramic insulator is cracked or broken.

 

 

 

 

-

replace the push button ignitor.

 

 

Out of propane gas

-

fill the tank.

 

 

 

 

 

 

 

 

Spark gap is incorrect

-

spark gap should be 0.150" to 0.175" (5/32" to 11/64" approx.) from

 

 

 

 

the electrode tip and the pilot burner. To ensure proper electrode loca-

 

 

 

 

tion, tighten securing nut (finger tight plus 1/4 turn).

 

 

No gas at the pilot burner

-

check that the manual valve is turned on.

 

 

 

 

-

check the pilot orifice for blockage.

 

 

 

 

-

replace the valve.

 

 

 

 

-

call the gas distributor.

 

 

 

 

 

 

 

Main burner goes

Pilot flame is not large

-

turn up pilot flame.

 

out; pilot stays on.

enough or not engulfing the

- replace pilot assembly.

 

 

thermopile

 

 

 

 

Thermopile shorting

- clean thermopile connection to the valve. Reconnect.

 

 

 

 

- replace thermopile / valve.

 

 

Remote wall switch wire is too

-

shorten wire to correct length or wire gauge.

 

 

long; too much resistance in

 

 

 

 

the system.

 

 

 

 

 

 

 

 

 

 

Faulty thermostat or switch.

-

replace.

 

Main burner goes out; pilot goes out.

Refer to "MAIN BURNER GOES OUT; PILOT STAYS ON"

Vent is blocked

-

check for vent blockage.

 

 

 

Vent is re-circulating

-

check joint seals and installation.

 

 

 

4" flexible vent has become

-

re-attach to fireplace.

disconnected from fireplace.

 

 

Remote wall switch is in "OFF" position; main burner comes on when gas knob is turned to "ON" posi- tion.

Wall switch is mounted up-

- reverse.

side down

 

Remote wall switch is

- replace.

grounding.

 

 

 

Remote wall switch wire is

- check for ground (short); repair ground or replace wire.

grounding.

 

Faulty valve.

- replace.

W415-0447 / B / 05.24.05

Image 28
Contents W415-0447 / B What to do if YOU Smell GAS Table of Contents Napoleon GAS Fireplace Presidents Lifetime Limited Warranty General Instructions General InformationCare of GLASS, and Plated Parts VentingVenting Lengths & AIR Terminal Locations Definitions TOP Exit / Horizontal TerminationElbow Vent Length Values V190 TOP Exit Vertical Termination TOP Vertical Termination Formula 1 HT 3VT Formula 2 HT + VT 40 feet ExampleAIR Terminal Installations Horizontal Installation Installation Wall and Ceiling ProtectionVertical Installation Horizontal AIR Terminal Installation Using Flexible Vent ComponentsVertical AIR Terminal Installation Extended Horizontal AIR Terminal Installation Using Rigid Vent ComponentsFireplace Vent Connection Vertical Venting Installation GAS Installation Restricting Vertical VentsFraming Clearance to CombustiblesHard Wiring Connection SchematicElectrical Connection Mantle ClearancesFinishing LOG Shipping BracketLOG Placement Baffle InstallationGlowing Embers Charcoal EmbersBlower Replacement Lamp ReplacementRemote and Valve Access Inner Access DoorControl Door Remote Receiver RemovalFireplace Operation Operation / MaintenanceHand Held Remote Operation Operating Instructions Adjustments MaintenancePilot Burner Adjustment Venturi AdjustmentReplacements W415-0447 / B Trouble Shooting Guide Symptom Problem Test SolutionStanding Main