Napoleon Fireplaces GD80NT, GD80PT manual TOP Exit / Horizontal Termination, Definitions

Page 7

DEFINITIONS

for the following symbols used in the venting calculations and examples are:

>- greater than

>- equal to or greater than < - less than

< - equal to or less than

HT - total of both horizontal vent lengths (HR) and offsets (HO) in feet

HR - combined horizontal vent lengths in feet

HO - offset factor: .03(total degrees of offset - 90°*) in feet

VT - combined vertical vent lengths in feet

7

ELBOW VENT LENGTH VALUES

 

feet

inches

0.03

0.5

15°

0.45

6.0

30°

0.9

11.0

45°

1.35

16.0

90°*

2.7

32.0

*the first 90° offset has a zero value and is shown in the formula as -90°

TOP EXIT / HORIZONTAL TERMINATION

FIGURE 4

See graph to determine the required vertical rise VT for the required horizontal run HT.

VERTICAL

RISE IN

FEET

VT

HORIZONTAL VENT RUN PLUS OFFSET IN FEET HT

The shaded area within the lines represents acceptable values for HT and VT .

For vent configurations requiring more than one 90° elbow, the following formulas apply:

Formula 1: HT < VT

Formula 2: HT + VT < 40 feet

Example 1:

90°

H2

 

 

FIGURE 5

V2

90°

H1

90°

V1

V1

=

3 ft

 

V2

=

8 ft

 

VT

= V1

+ V2 = 3 + 8 = 11 ft

H1

=

2.5 ft

H2

=

2 ft

 

HR

= H1

+ H2 = 2.5 + 2 = 4.5 ft

HO

= .03(three 90° elbows - 90°) = .03(270° - 90°) = 5.4 ft

HT

=

HR + HO = 4.5 + 5.4 = 9.9 ft

HT + VT = 9.9 + 11 = 20.9 ft

Formula 1: HT < VT 9.9 < 11

Formula 2: HT + VT < 40 feet 20.9 < 40

Since both formulas are met, this vent configuration is acceptable.

W415-0447 / B / 05.24.05

Image 7
Contents W415-0447 / B What to do if YOU Smell GAS Table of Contents Napoleon GAS Fireplace Presidents Lifetime Limited Warranty General Information General InstructionsCare of GLASS, and Plated Parts VentingVenting Lengths & AIR Terminal Locations Definitions TOP Exit / Horizontal TerminationElbow Vent Length Values V190 TOP Exit Vertical Termination Formula 1 HT 3VT Formula 2 HT + VT 40 feet Example TOP Vertical TerminationAIR Terminal Installations Horizontal Installation Installation Wall and Ceiling ProtectionVertical Installation Horizontal AIR Terminal Installation Using Flexible Vent ComponentsVertical AIR Terminal Installation Extended Horizontal AIR Terminal Installation Using Rigid Vent ComponentsFireplace Vent Connection Restricting Vertical Vents Vertical Venting Installation GAS InstallationClearance to Combustibles FramingMantle Clearances Hard Wiring ConnectionSchematic Electrical ConnectionLOG Shipping Bracket FinishingCharcoal Embers LOG PlacementBaffle Installation Glowing EmbersLamp Replacement Blower ReplacementRemote Receiver Removal Remote and Valve AccessInner Access Door Control DoorFireplace Operation Operation / MaintenanceHand Held Remote Operation Operating Instructions Venturi Adjustment AdjustmentsMaintenance Pilot Burner AdjustmentReplacements W415-0447 / B Symptom Problem Test Solution Trouble Shooting GuideStanding Main